54M-1BB-1AL Grayhill Inc, 54M-1BB-1AL Datasheet - Page 62

no-image

54M-1BB-1AL

Manufacturer Part Number
54M-1BB-1AL
Description
54M30-01-1-03N & 01-1-12N-C T, Military 85&deg
Manufacturer
Grayhill Inc
Datasheet

Specifications of 54M-1BB-1AL

, 30°
, 1 Deck, 1 Pole/deck, 2 Positions/pole, Non-shorting & 1 Deck, 1 Pole/deck, 2 Positions/pole, Non-shorting, 54M-1BA-1BA
Lead Free Status / Rohs Status
Compliant
CIRCUIT DIAGRAMS: Series 59
CIRCUIT DIAGRAMS: Series 53
Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois
15° Angle
of Throw
18° Angle
of Throw
10
11
9
8
12
7
13
6
ONE POLE
14
5
C3
15
4
16
3
10
C2
11
9
8
12
FIVE OR SIX POLE
17
7 /
2
7
8
7
1
9
18
13
6
Switch is Viewed From Shaft End and Shown in Position No. 1
1
6
2
10
Switch is Viewed From Shaft End and Shown in Position No. 1
˚
5
19
14
24 45˚
5
C4
ONE POLE
20
23
C1
11 12 13
22
21
4
4
15
16 17
3
3
Note: All common terminals are located above base terminals as shown.
C
C1
L
Note: All common terminals are located above base terminals as shown.
C
2
L OF
OF BUSHING
KEYWAY
2 1
18
1
POSITION
NO. 1
14
19
24
20
C5
23
20
C
15
21
C1
22
L
16
19
18˚
C3
10
17
18
C
C1
9
11
L
8
C2
12
C6
7
OF POSITION
NO. 1
8
7
C
9
6
L
13
6
45˚
10
TWO POLE
OF BUSHING
KEYWAY
5
5
C3
14
C4
11 12 13
FIVE POLE
SEVEN OR EIGHT POLE
4
15
4
10
11
9
3
16 17
8
3
12
7
2
6
2 1
13
C5
C2
18
C4
1
14
5
14
C1
19
24
8
7
C1
C2
15
15
23
4
9
20
C
6
20
21
22
L
10
16
19
3
16 17
5
17
60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com
18
TWO POLE
11 12 13
2
C
4
C1
L
C5
10
18
C6
1
C2
11
9
8
12
3
19
7
24
20
23
13
6
21
22
C
2 1
L
THREE POLE
C1
5
14
14
C4
C7
C8
15
C5
4
15
20
C3
16
SIX THRU TEN POLE
19
3
16 17
C5
17
18
8
7
9
6
C4
NINE THRU TWELVE POLE
10
C6
C2
2
C
L
5
C6
18
1
10
11 12 13
9
11
4
19
8
12
24
C2
23
7
20
C
C3
21
22
L
C7
3
13
6
C2
THREE OR FOUR POLE
14
5
2 1
C3
C7
Multi-Deck Rotary Switches
14
15
4
8
7
C8
C2
9
C2
6
10
C1
16 17
3
15
20
10
5
19
11
9
16
12
8
2
C8
11
17
18
C3
7
4
45˚
18
C1
C9
1
C1
13
12 13
C
6
C10
L
FOUR POLE
19
C9
3
24
14
5
20
23
21
22
2 1
4
C3
15
C10
C12
14
3
16 17
C11
C
L
15
20
7 /
C
2
L OF POSITION
OF BUSHING
KEYWAY
1
16
19
17
18
18
1
NO. 1
C1
19
C
24
L
20
23
21
22
C4
C
L
C4
See following page for Series 57, 22
throw circuitry.
SEE NOTE
SEE
DETAIL
SEE
DETAIL
SEE NOTE
Note: Common location for a single pole per
Note: Common location for a single pole per
(0,86 ± 0,08)
.034 ± .003
deck switch. For common location on
multipole switches see circuit diagrams.
deck switch. For common location on
multipole switches see circuit diagrams.
Terminal Detail
Rear View
Rear View
OVER TERMINALS
OVER TERMINALS
GRAYHILL
GRAYHILL
GRANGE
GRANGE
ILLINOIS
(30,23 ± 0,38)
(34,29 ± 0,38)
ILLINOIS
1.350 ± .015
1.190 ± .015
LA
LA
.068 ± .005
(1,73 ± 0,13)
1
/
2
° angle of
F-62

Related parts for 54M-1BB-1AL