84-8512.5640 EAO, 84-8512.5640 Datasheet - Page 4

SWITCHING ELEMENT, 1NO, 3A, CABLE

84-8512.5640

Manufacturer Part Number
84-8512.5640
Description
SWITCHING ELEMENT, 1NO, 3A, CABLE
Manufacturer
EAO
Datasheet

Specifications of 84-8512.5640

No. Of Poles
1
Contact Current Max
3A
Contact Voltage Ac Max
240V
Switch Terminals
Cable
Circuitry
1NO
For Use With
84 Series Emergency Stop Switches
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Technical Data
Emergency stop
Switching system
The double-break switching system can be supplied for the
following switching functions :
1 Normally closed, 2 Normally closed,
1 Normally closed + 1 Normally open.
The Normally closed contacts have forced opening according to
EN IEC 60947-5-1
Material
Connection cable
Polyvinylchlorid (PVC), operating temperature up to +70 °C.
Degression curve for higher current and temperature on request
Lens
Polybutylenterephthalat (PBT), as per UL94 V0 (red items)
Actuator housing
Polyamid (PA66), as per UL94 V0, Flat ribbon cable cover
Polyamid (PA 6.6), as per UL94 V0
Material of contacts
Silver alloy gold plated
Mechanical characteristics
Mounting hole
22.5 mm dia. as per EN IEC 60947-5-1 with anti-twist device
Terminals
Terminals 2.8 x 0.8 mm (solderable) CuSn6 tin-plated
Flat ribbon cable 2, 4 or 6 wires 0.5mm
Tightening torque
Fixing nut 80 Ncm
Actuation force
22 N ±4 N
Actuation travel
Approx. 4 mm to release the internal operation part
Mechanical life
Panel strength
Standard mounting 1-4mm
With protection collar 1-3mm
Electrical characteristics
Standards
The devices comply with: EN IEC 60947-5-1, EN IEC 60947-5-5
(Emergency-stop), EN 418, EN IEC 60204, DIN IEC 60512-2
Illumination
LED red with pole reversal, constant current source
Operation voltage: 5 VDC ... 30 VDC
Current consumption: 11.4 mA ... 12.8 mA
Rated operational voltage
U
50.000 cycles of operations
e
= 250 VAC, as per EN IEC 60947-1
2
(AWG 22)
2
Rated insulation voltage
U
Rated impulse withstand voltage
U
Contact resistance
New state: 50 m , as per DIN IEC 60512-2-3
Isolation resistance
>10
as per DIN IEC 60512-2-10
Electrical life
Inductive:: 50.000 cycles of operations, as per EN IEC 60947-5-1
Voltage: 120 VAC
Current: 3 A
Resistive:: >50.000 cycles, reduced load
Voltage: 1 VAC/DC 42 VAC/DC
Current: 100 mA
Conventional free air thermal current
I
the maximum current in continuous operation and at ambient
temperature must not exceed the quoted maximum values
Switch rating
Switch rating AC with silver contact (gold plated), service category
AC-15, as per EN IEC 60947-5-1
Voltage: 120 VAC
Current: 3 A
Switch rating DC for silver contact (gold plated), service category
DC-13, as per EN IEC 60947-5-1 (inductive)
Voltage: 12 VDC
Current: 5 A
Recommended minimum operational data
Silver contacts (gold plated)
Voltage: 1 VAC/DC
Current: 1 mA
Electric strength
500 VAC, 50 Hz, 1 min, as per DIN IEC 60512-2/A1
Rated conditional short-circuit current
1000 A, type of short-circuit unit 6 A gL/gG, as per
EN IEC 60947-5-1
Protection class
Class II, as per EN IEC 61058-1
Overvoltage category
Class II, as per EN IEC 60947-1/H.1
Degree of pollution
Class 3, as per EN IEC 60947-1
Environmental conditions
Storage temperature
-40 °C ... +85 °C
Operating temperature
-25 °C ... +60 °C
Front protection
IP 65, as per EN IEC 60529
th
i
imp
= 5 A, as per EN IEC 60947-5-1
= 250 V, as per EN IEC 60947-1
11
= 2.5 kV, as per EN IEC 60947-1
between the opened contacts at 500 VDC,
240 VAC 125 VDC 250 VDC
1.5 A
200 mA
240 VAC
1.5 A
24 VDC
4 A
0.55 A
48VDC
2.1 A
0.27 A
60VDC
1.7 A
Series 84
125VDC 250VDC
0.55 A
103
0.27A