HS9Z-A3 IDEC, HS9Z-A3 Datasheet - Page 5

no-image

HS9Z-A3

Manufacturer Part Number
HS9Z-A3
Description
HS9Z-A3 Adj. Key For HS1B/HS2B/HS1C/HS1E
Manufacturer
IDEC
Datasheet

Specifications of HS9Z-A3

Mounting Hole Dia
3.2mm
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
HS1E Series Door Interlock Switches
388
HS1E-24 (Main Circuit: 1NC+1NC, Auxiliary Circuit: 1NC+NC)
HS1E-34 (Main Circuit: 1NC+1NC, Auxiliary Circuit: 1NC)
Switch/Door
Status
Door
Circuit
Diagram
Main Circuit
Aux. Circuit
Solenoid
Switch/Door
Status
Door
Circuit
Diagram
Main Circuit
Aux. Circuit
Solenoid
1. Main Circuit: used to enable the machine to start only when the main circuit is closed.
2. Auxiliary Circuit: used to indicate whether the machine circuit or door is open or closed.
3. Terminals 7 and 8 are used for the LED indicator, and are isolated from solenoid or door status.
Contacts are linked to the
solenoid mechanically
Door Closed
Machine ready to operate
Solenoid de-energized
Door Closed
Machine ready to operate
Solenoid de-energized
Contacts are linked to the
solenoid mechanically
5-6: Power OFF
5-6: Power OFF
HS1E Series
3-4: Closed
1-2: Closed
3-4: Closed
1-2: Closed
Status 1
Status 1
Application Examples and Circuit Diagrams, continued
Door Closed
Machine cannot be started
Solenoid energized
Door Closed
Machine cannot be started
Solenoid energized
Contacts are linked to the
solenoid mechanically
Contacts are linked to the
solenoid mechanically
5-6: Power ON
5-6: Power ON
1-2: Closed
3-4: Open
1-2: Open
3-4: Open
Status 2
Status 2
www.idec.com
Contacts are linked to the
solenoid mechanically
Door Opened
Machine cannot be started
Solenoid energized
Door Opened
Machine cannot be started
Solenoid energized
Contacts are linked to the
solenoid mechanically
5-6: Power ON
5-6: Power ON
3-4: Open
1-2: Open
3-4: Open
1-2: Open
Status 3
Status 3
Door Opened
Machine cannot be started
Solenoid de-energized
Door Opened
Machine cannot be started
Solenoid de-energized
Contacts are linked to the
solenoid mechanically
Contacts are linked to the
solenoid mechanically
(Note)
5-6: Power OFF
5-6: Power OFF
3-4: Open
1-2: Open
3-4: Open
1-2: Open
Status 4
Status 4
Door Interlock Switches
Contacts are linked to the
solenoid mechanically
Contacts are linked to the
solenoid mechanically
Door Closed
Machine cannot be started
Solenoid de-energized
Door Closed
Machine cannot be started
Solenoid de-energized
Unlocked Manually
Unlocked Manually
5-6: Power OFF
5-6: Power OFF
1-2: Closed
3-4: Open
1-2: Open
3-4: Open