253-TALU-LSHG-C6-A5 Tyco Electronics, 253-TALU-LSHG-C6-A5 Datasheet - Page 9

Current Transducer

253-TALU-LSHG-C6-A5

Manufacturer Part Number
253-TALU-LSHG-C6-A5
Description
Current Transducer
Manufacturer
Tyco Electronics
Datasheet

Specifications of 253-TALU-LSHG-C6-A5

Current Measuring Range Ac
1A To 10A
Sensor Output
Current
Frequency Max
60Hz
Transducer Output Current Dc Max
20mA
Frequency Min
50Hz
Transducer Input Current Ac Max
5A
Output Current Max
20mA
Lead Free Status / RoHS Status
na
Paladin Transducers 250 Series Class 0.5
Linear Integrator Pulsed Output Transducer
Typical applications result in pulses proportional to kilowatt-hours, ampere hours,
litre-hours etc., depending on the transducer or transmitter used. Accepts inputs
in the form of a process signal derived from transducers or transmitters and
integrates them with respect to time, to produce a pulsed output via volt free
relay contacts. Converts a D.C. input into a pulsed kilowatt hour and ampere hour
measurement output.
Specification
Product Code – Linear Integrator
Signal Isolator
The signal isolator is designed for use in signal transmission and processing
applications to prevent noise and interference caused by ground loops between
signal source and the measuring device. The isolator provides galvanic high voltage
isolation between source and measuring device.
Specification
Product Code – Signal Isolator
Inputs:
Output:
Pulse rate:
Auxiliary Power:
Input/Output Ratio:
Max Input/Output:
Accuracy:
Isolation:
Test Voltage:
Load Range:
Output Voltage:
Input Voltage:
UL File Number:
CSA File Number:
Input D.C.
0/1mA
20mA
Input
Pulses per hour
Specify
17
0/1mA, 4/20mA, 0/5mA, 0/10mA, 0/20mA,
0/1V D.C., 0/10V D.C.
Volt free relay contacts.
Minimum 100/hour maximum 10,000/hour, specify.
63.5, 110, 120, 139, 208, 220, 240, 277, 380, 415, 440,
480V A.C.
1 to 1
20mA D.C.
0.2% at 250 ohms
660V A.C., 930V D.C. continuous
1.5kV at 50Hz for 1 minute
0-500 ohms @ 20mA D.C.
I out x R Load limited to 15V
Typically I x (load + 200Ω) limited to 18V
E149713N
LR52592
A.C. Aux
O/P D.C.
0/20mA
Power
120V
253-TIK*-FAPO-DG
Catalogue No.
Catalogue No.
250-ISA*-HF
Connection Diag.
Connection Diag.
13
5