D10DNFPQ BANNER ENGINEERING, D10DNFPQ Datasheet - Page 4

Photoelectric Sensor

D10DNFPQ

Manufacturer Part Number
D10DNFPQ
Description
Photoelectric Sensor
Manufacturer
BANNER ENGINEERING
Type
Dual Discrete Outputr
Datasheets

Specifications of D10DNFPQ

Sensor Output
NPN
Sensor Input
Fiber Optic
Output Type
Transistor
Contact Current Max
150mA
Switch Terminals
Quick Connect
Body Style
Rectangular
Brand/series
Expert™
Cable Type
6-Pin Pico-Style QD
Current, Switching
150 mA
Function
Fiber Optic
Indicator
LCD
Ip Rating
IP50
Material, Casing
Black ABS⁄Polycabonate Alloy (Housing)
Material, Cover
Polycarbonate
Mounting Type
DIN Rail
Output
NPN
Primary Type
Photoelectric
Sensing Mode
Selectable
Technology
Photoelectric
Temperature, Operating
-20 to +55 °C
Termination
6-Wire Cable
Time, Response
50 μs, 200 μs, 1 ms, 2.5 ms
Voltage, Supply
24 VDC
Accessories Available
Cordsets and Plastic Fiber Optic Cable
Fiber Optic Sensor Type
Dual Discrete Output
Lead Free Status / Rohs Status
RoHS Exempt Product
D10 Expert
Static TEACH is the traditional setup method, used when two conditions can be presented
by the user. The sensor locates a single sensing threshold (the switchpoint) midway between
the two taught conditions, with the Output ON condition on one side, and the Output OFF
condition on the other (see Figure 2).
The first condition taught is the ON condition. The Output ON and OFF conditions can be
reversed by changing Light/Dark Operate status in SETUP mode (see page 10).
Static TEACH and Manual Adjust
Using Manual Adjust with Static TEACH moves the switching threshold.
4
• Establishes a single switching threshold
• Threshold position is adjustable using “+” and “-” buttons (see Manual Adjust, page 9)
P/N 64154 rev. F
• Press and
• Present Output
• C lick Static
• Present Output
• C lick Static
button.
button.
hold Static (-)
button > 2
seconds.
ON condition.
OFF condition.
Two-Point Static TEACH (Threshold)
Push Button
Dual Discrete Outputs
T
T
T
T
T
T
• No action required;
• Present Output ON
• Single-pulse the
• Present Output OFF
• Single-pulse the
T
T
sensor is automatically
ready for 1st TEACH condition.
condition.
remote line.
condition.
remote line.
T
0.04 sec. ≤ T ≤ 0.8 sec.
T
T
T
Remote
T
T
T
T
T
T
T
T
• Display flashes “1st”
• Arrow icon turns red
• Display flashes “2nd”
TEACH conditions acceptable:
• Display flashes “pass,” followed
• Sensor returns to RUN mode with
• Arrow icon turns green
TEACH conditions unacceptable:
• Display flashes “fail” and
returns to “1st”
• Arrow icon remains red
• After 60 seconds, sensor returns
by a number (denoting contrast);
see Figure 3.
new settings.
to RUN mode (Arrow icon
turns green) without changing
settings.
Banner Engineering Corp.
www.bannerengineering.com • Tel: 763.544.3164
Figure 3. Contrast Values
Figure 2. Static TEACH (Light Operate
(no signal)
(no signal)
(no signal)
Darkest
Darkest
Darkest
100-500
32-99
500+
0-31
Darkest Taught
Output OFF
2nd Taught
Condition
Condition
Output OFF
Output OFF
shown)
Result
between taught conditions
between taught conditions
Contrast Values
Excellent: Very stable operation.
Good: Minor sensing variables will
not affect sensing reliability.
Low: Minor sensing variables may
affect sensing reliability.
Marginal: Consider an alternate
sensing scheme.
Sensing window size
threshold midway
threshold midway
Sensor positions
Sensor positions
Manual Adjust
Manual Adjust
Manual Adjust
adjusted by
adjusted by
adjusted by
Output ON
condition
Position
Position
sensing
Single
Minneapolis, MN U.S.A.
Output ON
Output ON
Lightest Taught
1st Taught
Condition
Condition
Output OFF
Most Light
Most Light
Most Light
(saturated
(saturated
(saturated
signal)
signal)
signal)

Related parts for D10DNFPQ