E3XNA41F2M Omron, E3XNA41F2M Datasheet
E3XNA41F2M
Specifications of E3XNA41F2M
Related parts for E3XNA41F2M
E3XNA41F2M Summary of contents
Page 1
User-Friendly Fiber-Optic Amplifier Solve Your Basic Sensing Challenges Easily with the E3X-NA Series I Streamlined features provide basic sensing immediately after plug-in I Wire-saving amplifiers reduce installation time and minimize space requirements I Master/slave connector design affords connectivity for up ...
Page 2
... Fiber-Optic Cables I The E3X-NA amplifiers use Omron’s E32-series fiber-optic cables. With a choice of over 80 sensing heads, you are sure to find one that matches your application requirements. Refer to the Part number selection of E32 cables (listed with their respective sensing distances) in the fiber section at the end of this data sheet. Order E39-L143 fiber-optic cables separately ...
Page 3
E3X-NA Specifications Amplifier Units I Ratings/Characteristics Item Amplifier Units with Cables Standard models Output type NPN output E3X-NA11 PNP output E3X-NA41 Light source (wavelength) Red LED (680 nm) Supply voltage VDC ±10%, ripple (p-p): 10% max. Current ...
Page 4
E3X-NA Nomenclature Amplifier Units I Sensitivity Indicator 8-Turn Sensitivity Adjuster Operation Mode Selector Use to switch between Lock Button Incident level Indicators Light ON and Dark ON modes. Operation Indicator Timer Switch ON: Timer function is ON. OFF: Timer function ...
Page 5
E3X-NA Operation Output Circuits I Output Model Mode Timing chart selector NPN E3X-NA11 LIGHT Incident light E3X-NA6 ON No incident light E3X-NAG11 (L/ON) Operation indicator E3X-NA11F (orange) E3X-NA11V Output E3X-NA14V transistor Load (relay) DARK Incident light ON No incident light ...
Page 6
E3X-NA Engineering Data (Typical) Parallel Operating Range I At max. sensitivity. (Use for optical axis adjustment at installation.) E32-TC200 300 X E3X-NAG@ Y 200 100 0 0.2 0.4 0.6 0.8 1 1.2 Distance X (m) −100 −200 E3X-NA@ (V) E3X-NA@F ...
Page 7
E3X-NA Number of Turns of Sensitivity Adjuster vs. Sensing Distance I E32-T11L 1.2 1.0 0.8 E3X-NA@ (V) 0.6 0.4 0.2 E3X-NA Number of turn ns Sensing Distance vs. Hysteresis E32-T11L 100 80 60 E3X-NA@ ...
Page 8
E3X-NA Dimensions Unit: mm (inch) Amplifier Units I Amplifier Units with Cables (with Mounting Bracket Attached) E3X-NA11 E3X-NA11F E3X-NA41 E3X-NA41F E3X-NAG11 E3X-NAG41 10 Two, 2.4 dia. (0.39) 8 10.7 Note: 1. The mounting bracket can also be used on side ...
Page 9
E3X-NA Wire-Saving Amplifiers E3X-NA6 E3X-NA8 10 (0.39) Two, 2.4 dia. 8 10.7 Dimensions with Master Connector Connected 71 (2.80) 67.5 64.3 31.5 (1.24) 1.5 1.8 5.1 3.9 M8 Connector-Ready, Water-Resistant Amplifier Units E3X-NA14V E3X-NA44V Two, 2.4 dia. 33 (1.30) 8 ...
Page 10
E3X-NA Amplifier Unit Connectors (Order Separately) I Master Connectors E3X-CN11 10 6 2.9 2.6 14.4 6 0.8 Note: A 4-dia., 3-conductor, vinyl-insulated round cable (conductor cross-sectional area: 0.2 mm Slave Connectors E3X-CN12 10 6 2.9 2.6 14.4 6 0.8 3 ...
Page 11
E3X-NA Accessories (Order Separately Mounting Bracket for E3X-NA , E3X-NA E39-L143 10.3 5.3 Material: Stainless steel (SUS 304) @ Mounting Bracket for E3X-NA V Models E39-L148 12 max. 12 Material: Stainless steel (SUS 304) End Plate PFP-M 4.8 ...
Page 12
E3X-NA Precautions Wiring Precautions I Read the following before using the Amplifier Unit and Sensor to ensure safety. Power Supply Voltage Do not impose any voltage exceeding the rated voltage on the E3X-NA. Do not impose AC power (100 VAC) ...
Page 13
E3X-NA Mounting the Amplifier Unit I Joining Amplifier Units 1. Mount the Amplifier Units one at a time onto the DIN rail. 2. Line up the clips and slide the Amplifier Units together. Then press the Amplifier Units together until ...
Page 14
E3X-NA Mounting the Fiber Unit I Tightening Force The tightening force applied to the Fiber Unit should be as shown below. Screw-Mounting Model Cylindrical Model Spring mounting clip Toothed washers Nuts (attachment) Fiber Units Clamping torque M3/M4 screw 0.78 N·m ...
Page 15
E3X-NA Connection Do not pull or press the Fiber Units. The Fiber Units have a with- stand force of 9 29.4 N maximum (pay utmost attention because the fibers are thin). Do not bend the edge of the ...
Page 16
E3X-NA Mounting End Plate (PFP-M) I Depending on how it is mounted, an Amplifier Unit may move during operation. In this case, use an End Plate. Before mounting an End Plate, remove the clip from the master Amplifier Unit using ...
Page 17
... E3X-NA Sensing Distance with Fiber Optic Cables Through-beam Fiber Units I Refer to the end of the following table for notes and precautions. Indicates models that allow free cutting. Models without this mark do not allow free cutting. Free-cut : Red light : Green light Application Features ...
Page 18
E3X-NA Application Features Appearance Flexible Ideal for Free-cut (R4) mounting on moving sections (R4) M4 screw M3 screw 1.5-mm dia. M4 Free-cut M4 screw 3-mm dia. Free-cut 3-mm dia. M3; small Free-cut diameter M3 screw 2-mm Free-cut dia.; small diameter ...
Page 19
E3X-NA Application Features Appearance Chemical- Teflon-cov- Free-cut resistant ered *1; with- stands chemicals and harsh envi- ronments (operating ambi- 5-mm dia. ent temperature:−30°C to 70°C) Teflon-cov- Free-cut ered *1; side- view; with- 5-mm dia. stands chemicals and harsh environments (oper- ...
Page 20
E3X-NA Application Features Appearance Multi-point detection Area sensing (4-head) M3 screw Detects in a Free-cut 30-mm area 30 mm Detects in Free-cut a 30-mm area; flexible 30 mm Side-view; Free-cut suitable for applica- tions with limited 11 mm spatial depth ...
Page 21
E3X-NA Fiber Units with Reflective Sensors I Refer to the end of the following table for notes and precautions. Indicates models that allow free cutting. Models without this mark do not allow free cutting. Free-cut : Red light : Green ...
Page 22
E3X-NA Application Features Appearance Flexible Ideal for mounting on moving sections Free-cut Free-cut Free-cut M6 Free-cut 3-mm dia. Free-cut M3; small Free-cut diameter 3-mm dia.; Free-cut small diameter 22 Applicable Sensing distance (mm) *1 Amplifier Unit E3X-NA@ (V) 90 E3X-NAG@ ...
Page 23
E3X-NA Application Features Appearance Coaxial M6coaxial; Free-cut high- precision positioning 3-mm dia. Free-cut coaxial; small diameter; high- precision positioning M3 coaxial; Free-cut high- precision positioning; possible to mount small-spot lens (E39-F3A-5/ F3B/F3C) M3 coaxial; high- precision position- ing; possible to ...
Page 24
E3X-NA Application Features Appearance Heat- Resists 150°C Free-cut resistant *2; fiber sheath materi- al: fluororesin (operating ambient temperature: −40°C to 150°C) Resists 300°C *4; fiber sheath material: stainless steel (operating ambient temperature: −40°C to 300°C) Resists 400°C *4; fiber sheath ...
Page 25
E3X-NA E3X-NA 25 ...
Page 26
E3X-NA 26 E3X-NA ...
Page 27
E3X-NA E3X-NA 27 ...
Page 28
... OMRON ELECTRONICS LLC One East Commerce Drive Schaumburg, IL 60173 1-800-55-OMRON Cat. No. E318-E3-1 10/01/7.5M 28 OMRON ON-LINE Global - http://www.omron.com USA - http://www.omron.com/oei Canada - http://www.omron.com/oci Specifications subject to change without notice E3X-NA OMRON CANADA, INC. 885 Milner Avenue Scarborough, Ontario M1B 5V8 416-286-6465 Printed in USA ...