S8011R MULTICOMP, S8011R Datasheet

FLOW SENSOR, LIQUID

S8011R

Manufacturer Part Number
S8011R
Description
FLOW SENSOR, LIQUID
Manufacturer
MULTICOMP
Datasheet

Specifications of S8011R

Pressure Max
10bar
Supply Voltage Range Dc
4.5V To 24V
Flow Measuring Range
3l/hr To 100l/hr
Connection Size
5.76mm
Flow Rate Max
1.66l/min
Flow Rate Min
0.05l/min
Supply Voltage Dc Max
24V
Current Consumption
20mA
External Depth
27mm
External Length / Height
78mm
Dimensions:
Technical Specifications:
Metering principle
System
Output signal
Flow direction
Flow Range:
Minimal
Maximum
Frequency
All information relates for H
Specifications:
Viscosity range
Sensor to sensor variation
Signal reproducibility
Operating-/bursting pressure
Temperature range
Pressure drop
Orientation
Power supply
Cable type
Cable connection
Body material
Weight
Flow Transducer
http://www.farnell.com
http://www.newark.com
http://www.cpc.co.uk
2
O at 22°C.
: Velocity counter.
: Hall effect sensor, touchless reading.
: Square wave pulses from open collector TTL, CMOS and LSI compatible.
: Bi-directional (but higher precision at indicated direction.
: 3.0L/Hr.
: 100L/Hr.
: 22Hz at 10L/Hr
: 45Hz at 20L/Hr
: 133Hz at 60L/Hr.
: ca. 1 to 10cSt.
: ±5%.
: ±5% at the same working condition.
: 10 bar/>30 bar (at 22°C).
: -26°C to +85°C.
: 0 to 1 bar (over range at 1cSt).
: As desired (however, most sensitive at low ranges when installed vertically with flow upwards).
: 4.5 to 24V dc, current consumption maximum 15mA at 24V.
: Screened cable.
: White or red
: Brown or blue
: Screen
: POM (hostaform C) body and rotor, SS shaft and ceramic magnets.
: 75g approximate (including cable).
Dimensions : Millimetres
= V+
= Output-signal
= 0V.
Page <1>
26/04/09 V1.1

Related parts for S8011R

S8011R Summary of contents

Page 1

... As desired (however, most sensitive at low ranges when installed vertically with flow upwards). : 4.5 to 24V dc, current consumption maximum 15mA at 24V. : Screened cable. : White or red = V+ ...

Page 2

... Information or use of it (including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group's liability for death or personal injury resulting from its negligence. SPC Multicomp is the registered trademark of the Group. © Premier Farnell plc 2009. http://www.farnell.com http://www.newark.com http://www.cpc.co.uk S8011R Page <2> 26/04/09 V1.1 ...

Related keywords