26602 Gems Sensors Inc, 26602 Datasheet

Flow Switch

26602

Manufacturer Part Number
26602
Description
Flow Switch
Manufacturer
Gems Sensors Inc
Datasheet

Specifications of 26602

Pressure Max
400psi
Accuracy
+/-10%
Operating Pressure Range
400psi Max.
Circuitry
SPDT
Body Material
Bronze
Contact Current Ac Max
500mA
Mounting Type
Conduit
Power Rating
20VA
Port Size
0.75"
Connection Size
3/4"
Contact Voltage Ac Max
250V
Features
Straight-Through Flow Path
Rohs Compliant
No
Accuracy %
10%
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
G-20
FS-400 Series –
General Purpose, 90° Flow Path
Flow Rate Settings: Fixed Version: 0.75 GPM to 10.0 GPM
Port Size: 3/4˝
Primary Construction Material: Bronze
Setting Type: Fixed or Adjustable
Provides accurate flow detection in water and oil with 1% repeatability. Flow settings
on the adjustable version can be easily changed without disassembly. A shuttle by-
pass vane inside the housing is controlled externally using an ordinary flat-blade
screwdriver. These switches are ruggedly constructed of non-corrosive materials and
resist shock and vibration. Suitable for triggering alarms on interlocking shutdown
circuitry when flow rate is improper to protect bearings, gears and cooling systems.
Specification
Wetted Materials
Pressure Rating, Maximum
Operating Temperature
Repeatability
Set Point Accuracy
Set Point Differential
Switch*
Inlet/Outlet Ports
Electrical Termination
*See “Electrical Data” on Page X-5 for more information.
How To Order – Standard Models
Specify Part Number based on flow settings for the FS-400 Series, based on flow
setting range for the FS-400 Adjustable version.
FS-400 Series
Notes:
1. Flow settings for Fixed Version are calibrated using water at +70°F on increasing flow, with units in a
2. Adjustable units that are set to customer specifications are subject to GEMS test stand accuracy.
3. Use of 150 micron filtration is recommended.
4. Minimum 5 PSI line pressure required.
Housing
Shuttle
Spring
O-Ring
Other Wetted Parts
Operating
Proof
vertical position (lead wires up). Temperature changes will slightly affect the flow settings listed.
– Stock Items.
NPT
3/4˝
Flow Setting
GPM
0.75
10.0
1.5
2.0
2.5
5.0
7.5
Adjustable Version: 0.75 GPM to 14.0 GPM
Numbers
26440
26441
26442
26443
26444
26445
26446
Part
Bronze
Delrin
316 Stainless Steel
Viton
Ceramic
400 PSI (27.6 bar) @ 100°F (+37.8°C)
800 PSI (55.2 bar) @ 100°F (+37.8°C)
-20°F to +180°F (-29°C to +82.2°C)
1% Maximum Deviation
±10%
15% Maximum
SPDT, 20 VA
3/4˝ NPT
No. 18 AWG, 24˝ L., Polymeric Lead Wires
®
®
Visit www.GemsSensors.com for most current information.
FS-400 Adjustable
NPT
3/4˝
Flow Setting
0.75-4.0
7.0-14.0
2.0-8.0
GPM
Numbers
26600
26601
26602
Part
Dimensions
Pressure Drop - Typical
FS-400 switches are U.L. Approved for Class I,
Division 2, Groups A, B, C, D hazardous areas.
Available with FM-approved, explosion-proof junction
box for Class I, Division 1, Group D hazardous locations.
Units must be assembled completely at GEMS.
U.L. Approved — File No. E183854
30
25
20
15
10
5
0
0
Tests conducted with units in vertical position (lead wires up) with water at
+70°F (21°C).
FS-400 Series
U.L. Recognized —
File No. E31926
CSA Listed —
LR30200 and LR22666
FM Approved —
File No. 0A8A3.AE and
1H3A2.AX
Part No. 26443
(97.6 mm)
3-27/32"
1-7/16" HEX
(36.5 mm)
(34.9 mm)
1-3/8"
5
FLOW RATE - GPM
Part No. 26446
10
(34.9 mm)
1-3/8"
FS-400 Adjustable
CSA Listed —
File No. LR22666
FM Approved —
File No. 0A8A3.AE
1/2" NPT
Part No. 26440
15
20

Related parts for 26602

Related keywords