SPS-L225-HDLS Honeywell Sensing and Control, SPS-L225-HDLS Datasheet - Page 2

LINEAR POSITION SENSOR. +/- 0.4%

SPS-L225-HDLS

Manufacturer Part Number
SPS-L225-HDLS
Description
LINEAR POSITION SENSOR. +/- 0.4%
Manufacturer
Honeywell Sensing and Control
Datasheet

Specifications of SPS-L225-HDLS

Operating Temperature Range
-40°C To +125°C
Length
227mm
Insulation Testing Voltage
0VAC To 600VAC
Sensing Range Min
0mm
Supply Voltage
24VDC
Supply Voltage Max
24VDC
Supply Voltage Min
6VDC
Linearity %
0.4%
Sensor Output
Digital
(Apply to both 75 mm and 225 mm configurations except
where noted.)
Industrial
Transportation
Table 1. Specifications
Notes:
2
Characteristic
Sensing range
Resolution
Supply voltage
Output
Supply current
Linearity
Reverse polarity
Sensitivity
Update rate
Baud rate
Initial startup time
Termination
Cable bend radius
Operating temperature
Storage temperature
Air gap
Sealing
Shock
Vibration
Housing material
Approvals
Mounting:
Material
Strength
screws
recommended torque
Percent linearity is the quotient of the measured output deviation from the best fit line at the measured temperature to the full scale output span.
Valve position: May be used to monitor valve position so
the desired amount of liquid is delivered based on the
position of the valve that is opening/closing, and how long
open/closed (e.g., bottling machines, food/chemical
processing, water handling equipment, etc.).
Material handling: May be used on a lifting device that
moves cartons from one conveyor belt to another.
Plastic molding: May be used for injection positioning.
Cutting and slitting: May be used in paper mills to
accurately control the location of the slitter before it cuts.
Wafer handling: May be used to monitor if parts are
properly placed.
CNC machines: May be used to monitor tool depth and
direction of travel.
Passenger bus level position: May be used for passenger
bus leveling to simplify access for passengers and luggage.
Truck-mounted crane outrigger position: May be used to
determine that the outriggers are fully deployed before the
lifting of objects can begin.
www.honeywell.com/sensing
Component
actuator
actuator
magnet
magnet
sensor
sensor
only
only
and
0 mm to 75 mm [0 in to 3.0 in]
20 G from 10 Hz to 2000 Hz
(SPS-L075-HALS)
0,05 mm [0.002 in]
50 mV/mm typ.
32 mA max.
Analog
75 mm
flying leads: red = supply voltage, black = ground, green = output
0 Vdc to 5 Vdc
50 G half sine wave with 11 ms duration
6 N m to 8 N m [53.1 in lb to 70.8 in lb]
Medical
Aerospace
400 µs
-40 °C to 125 °C [-40 °F to 257 °F]
-40 °C to 150 °C [-40 °F to 302 °F]
Heavy equipment attachment identification: May be used to
sense which attachments are being deployed onto heavy
equipment by the strategic placement of the magnet to the
sensor. The corresponding output indicates to the operator
and control system which attachment is connected.
Hydraulic cylinders: May be used on non-ferrous hydraulic
cylinders for non-contact stroke position (225 mm
configuration only).
Marine motors: May be used for trim position on
inboard/outboard motors for enhanced durability and
performance.
Syringe pumps: May be used to monitor syringe plunger
position to deliver the correct amount and rate of
medication to the patient.
Aircraft actuators: May be used to control actuator position
on multiple applications in the aircraft, helping to regulate
airflow to engines and environmental systems.
3,0 ±2,5 mm [0.118 ±0.098 in]
26.4 V at 125 °C [257 °F]
±0.4% full scale output
40 mm [1.6 in] min.
0,14 mm [0.0055 in]
6 Vdc to 24 Vdc
(SPS-L225-HALS)
17.78 mV/mm typ.
10,000 Gauss
thermoplastic
IP67, IP69K
neodymium
¼-20 or M6
Parameter
34 mA max.
30 ms
Analog
CE
0 mm to 225 mm [0 in to 8.86 in]
10 G from 10 Hz to 2000 Hz
225 mm
0,0035 mm [0.000137 in]
282.16 counts/mm typ.
(SPS-L225-HDLS)
RS232-type digital
88 mA max.
57.6 kbits/s
3200 µs
Digital