RDT10A ETERNA, RDT10A Datasheet - Page 2

PHOTOCELL, WITH TIMER

RDT10A

Manufacturer Part Number
RDT10A
Description
PHOTOCELL, WITH TIMER
Manufacturer
ETERNA
Datasheet

Specifications of RDT10A

Svhc
No SVHC (15-Dec-2010)
Colour
Grey
External Depth
38mm
External Length / Height
110mm
External Width
68mm
Ip/nema Rating
IP 44
Safety markings:
Read this first:
>
>
>
>
>
>
>
>
>
>
>
Installation:
1)
2)
3)
4)
5)
6)
7)
8)
9)
10) Restore the power, the load will flash 3 times and then go off when power is first applied.
11) Adjust the Lux and Timer controls to suit the individual installation.
12) Replace the front cover ensuring that the thin gasket is in place to preserve the IP rating and
This fitting must be installed in accordance with the Building Regulations. These may be
obtained from HMSO or viewed and downloaded from www.odpm.gov.uk following the link for
Building Regulations.
If in any doubt, consult a qualified electrician.
Switch off the mains before commencing installation and remove the appropriate circuit fuse.
Suitable for outdoor use.
This product is suitable for installation on surfaces with normal flammability ( indicated by the "F" in
a triangle ) e.g. wood, plasterboard, masonry. It is not suitable for use on highly flammable
surfaces ( e.g. polystyrene, textiles ).
Before making fixing hole(s), check that there are no obstructions hidden beneath the mounting
surface such as pipes or cables.
Do not attach to surfaces which are damp, freshly painted or otherwise electrically conductive (e.g.
metallic surfaces).
If the location of your new fitting requires the provision of a new electrical supply, the supply must
conform with the requirements of the Building Regulations.
Make connections to the electrical supply in accordance with the following code:
This fitting is double insulated, do not connect any part to earth.
You are advised at every stage of your installation to double-check any electrical connections you
have made. After you have completed your installation there are electrical tests that should be
carried out: these tests are specified in the Wiring Regulations ( BS7671 ) referred to in the
Building Regulations. If in doubt, consult a qualified electrician.
Select an open area for installation where artificial light (especially the controlled load) will not
enter the window on the front of the unit.
Release the four screws in the front and remove the front panel.
Mark the fixing points using the case as a template.
The power and switching cables can be fitted by making small holes in the cable entry grommet or
through the knock outs in the rear panel.
If using the knock outs suitable cable entry glands should be used to preserve the IP rating.
Secure the cables under the cable clamp which is fitted with 2 screws.
Connect the supply cables to the L in & N in terminals and the lighting load to the L out & N out
terminals.
Ensure that the connections are secure and there are no “ whiskers” or bare wires free of the
terminals.
Fit the product to the mounting surface using fixings suitable for the installation.
tighten the four screws.
Live - Brown or Red
Neutral - Blue or Black
IP44
13) When the set Lux level has been reached the LED illuminates to indicate that the load will be
14) The LED flashes once if the timer is set for one hour, twice for between one and two hours and up to
15) In the case of Dusk to Dawn setting the LED will flash rapidly nine times.
Please note the following:
When the load is switched on and the intensity of another light source exceeds the off Lux value the load
will be switched off after approximately 60 seconds and the timer will stop counting back to the set switch
off time period. If the other light source is extinguished within 10 minutes the load will be switched on again
and the timer will restart counting back to the set switch off time period.
During the timed period the electronic timer will be reset (I.e. will return to the start of the set time period)
under the following conditions:
1.
2.
switched on in 60 seconds (approx).
8 times for between 7 and 8 hours.
If the Lux value exceeds the switch off value for more than 10 minutes.
The power is interrupted for more than 2 seconds.
Lux Adjustment Guide