Q60BB6LAF1400 BANNER ENGINEERING, Q60BB6LAF1400 Datasheet - Page 9

PHOLOELECTRIC SENSOR

Q60BB6LAF1400

Manufacturer Part Number
Q60BB6LAF1400
Description
PHOLOELECTRIC SENSOR
Manufacturer
BANNER ENGINEERING
Datasheet

Specifications of Q60BB6LAF1400

Output Current
150mA
Supply Voltage Range Dc
10V To 30V
Supply Voltage and
Current
Supply Protection
Output Configuration
Output Rating
Output Protection
Circuitry
Output Response Time
Repeatability
Sensing Hysteresis
Indicators (see Figure 1)
NOTE: Outputs are
Laser Characteristics
Banner Engineering Corp.
www.bannerengineering.com • Tel: 763.544.3164
active during
on/off timing
selection mode.
Minneapolis MN, U.S.A.
Spot Size: approximately 4 x 2 mm throughout range (collimated beam)
Angle of Divergence: 5 milliradians
Q60BB6LAF models: 10 to 30V dc (10% maximum ripple) at less than 35 mA exclusive of load
Q60VR3LAF Universal models: 12 to 250V dc or 24 to 250V ac, 50/60 Hz
Input power 1.5 W maximum
Protected against reverse polarity and transient voltages
(Q60VR3 models’ dc hookup is without regard to polarity)
Q60BB6LAF models: Bipolar; one NPN (current sinking) and one PNP (current sourcing) open-collector
Q60VR3LAF cabled model: E/M Relay (SPDT), normally closed and normally open contacts
Q60VR3LAFQ1 (QD) model: E/M Relay (SPST), normally open contact
Q60BB6LAF models
Q60BB6LAF models
150 mA maximum each output @ 25° C
Off-state leakage current: < 5µA @ 30V dc
Output sat u ra tion NPN: < 200 mV @ 10 mA and < 1V @150mA
Output sat u ra tion PNP: < 1V at 10 mA; < 1.5V at 150 mA
Q60VR3LAF Universal models
Q60VR3LAF Universal models
Min. voltage and current: 5V dc, 10 mA
Mechanical life of relay: 50,000,000 operations
Electrical life of relay at full resistive load: 100,000 operations
Max. switching power (resistive load): Cabled models: 1250VA, 150 W
Max. switching voltage (resistive load): Cabled models: 250V ac, 125V dc
Max. switching current (resistive load):
Q60BB6LAF models: Protected against continuous overload or short circuit of outputs
All models: Protected against false pulse on power-up
NOTE: 1 second max. delay at power up (outputs do not conduct during this time).
Q60BB6LAF models: 2 milliseconds ON and OFF
Q60VR3LAF Universal models: 15 milliseconds ON and OFF
500 microseconds
See Figure 4.
ON-Delay
OFF-Delay
5-Segment Light Bar*
Cabled models: 5 A @ 250V ac, 5 A @ 30V dc derated to 200 mA @ 125V dc
QD models: 3 A @ 250V ac, 3 A @ 30V dc derated to 200 mA @ 125V dc
ON/OFF-Delay Selection: Indicates relative delay time
RUN Mode:
Q60LAF Series Laser Adjustable-Field Sensors
ON Green: RUN mode, ON-delay active
Flashing Green: ON-Delay Selection mode
ON Green: RUN mode, OFF-delay active
Flashing Green: OFF-Delay Selection mode
Output
Dark Operate
Lockout
Light Operate
Signal
transistor
Specifications
ON Yellow: Outputs are conducting
ON Green: ON/OFF-Delay Selection
ON Green: Dark Operate selected
ON Green: Buttons locked out
ON Green: Light Operate selected
ON Green: Sensor receiving signal
Flashing Green: Marginal signal (1.0 to 2.25 excess gain)
NOTE: Contact factory for custom laser spot size.
QD models: 750VA, 90W
QD models: 250V ac, 125V dc
P/N 114348
9

Related parts for Q60BB6LAF1400