SDX100G2 SENSYM, SDX100G2 Datasheet - Page 2

PRESSURE SENSOR, 0-100PSIG

SDX100G2

Manufacturer Part Number
SDX100G2
Description
PRESSURE SENSOR, 0-100PSIG
Manufacturer
SENSYM
Datasheet

Specifications of SDX100G2

External Depth
11.94mm
External Length / Height
15.1mm
External Width
13.97mm
Lead Spacing
2.54mm
Operating Pressure Range
0 To 100psig
Operating Temperature Max
85°C
Operating Temperature Min
-40°C
PRESSURE SENSOR CHARACTERISTICS (all devices)
Maximum ratings
Supply voltage V
Maxium pressure on any port
Lead temperature (soldering 4 sec.)
STANDARD PRESSURE RANGES
* Maximum pressure above which causes permanent sensor failure.
COMMON PERFORMANCE CHARACTERISTICS
June 2008 / 062
Specification notes:
10.
11.
Part number
SDX01...
SDX05...
SDX15A...
SDX15G2, ...D4
SDX30A...
SDX30G2, ...D4
SDX100A...
SDX100G2, ...D4
Characteristic
Zero pressure offset
Combined linearity and hysteresis
Temperature effect on span (0 to 50°C)
Temperature effect on offset (0 to 50°C)
Repeatability
Input impedance
Output impedance
Common-mode voltage
Response time
Long term stability of offset and span
1.
2.
3.
4.
5.
6.
7.
8.
9.
Reference conditions: supply voltage, V
For absolute devices only, pressure is applied to port 1 and the output polarity is reversed.
Span is the algebraic difference between the output voltage at full-scale pressure and the output at zero pressure. Span is
ratiometric to the supply voltage.
See Definition of Terms. Hysteresis - the maximum output difference at any point within the operating pressure range for
increasing and decreasing pressure.
Maximum error band of the offset voltage and the error band of the span, relative to the 25°C reading.
Maximum difference in output at any pressure with the operating pressure range and temperature within 0 to +50°C after:
Input impedance is the impedance between pins 2 and 5.
Output impedance is the impedance between pins 1 and 3.
This is the common-mode voltage of the output arms (pins 1 and 3) for V
Response time for a 0 psi to full-scale span pressure step change, 10 to 90 % rise time.
Long term stability over a one year period.
Maximum pressure at any port is the maximum operating plus common-mode pressure which can be applied. The proof
pressure for the forward gage of all devices in the D4-package is the specified value or 100 psi, whatever is less.
5
S
9
6
7
8
Low cost compensated pressure sensors in DIP package
Operating pressure
a) 100 temperature cycles, 0 to + 50°C
b) 1.0 million pressure cycles, 0 psi to full-scale span
3
0 - 100 psig/d
10
0 - 15 psig/d
0 - 30 psig/d
0 - 100 psia
0 - 1 psig/d
0 - 5 psig/d
0 - 15 psia
0 - 30 psia
4
4
S
= 12 V
150 psig
+20 V
250°C
DC
DC
, T
A
= 25°C, common-mode line pressure = 0 psig, pressure applied to port 2.
Proof pressure
Environmental specifications
Temperature ranges
Humidity limits
150 psi
150 psi
30 psi
30 psi
60 psi
60 psi
20 psi
20 psi
Min.
-1.0
1.3
---
---
---
---
---
---
---
---
1
Compensated
Operating
Storage
S
= 12 V
11
DC
.
Typ.
±0.2
±0.4
±0.2
±0.2
±0.1
100
4.0
4.0
3.0
0
17.37 mV
86.85 mV
86.85 mV
86.85 mV
86.85 mV
57.9 mV
96.5 mV
96.5 mV
www.sensortechnics.com
Min.
Full-scale span
Max.
+1.0
±1.0
±2.0
±1.0
±0.5
SDX Series
5.0
100 mV
100 mV
---
---
---
---
18 mV
60 mV
90 mV
90 mV
90 mV
90 mV
Typ.
-55 to +125°C
0 to 100% RH
1,2
-40 to +85°C
18.63 mV
93.15 mV
93.15 mV
93.15 mV
93.15 mV
103.5 mV
103.5 mV
62.1 mV
%FSO
%FSO
%FSO
Unit
µsec
Max.
mV
mV
V
mV
kΩ
kΩ
0 to 50°C
DC
2/4

Related parts for SDX100G2