E2K-C25MF2 Omron, E2K-C25MF2 Datasheet

Proximity Sensor

E2K-C25MF2

Manufacturer Part Number
E2K-C25MF2
Description
Proximity Sensor
Manufacturer
Omron
Series
E2K-Cr
Type
Proximity Sensorr
Datasheets

Specifications of E2K-C25MF2

Supply Voltage Range Dc
10V To 40V
Sensor Housing
Cylindrical
Sensing Range Min
3mm
Sensor Input
Capacitive
Sensing Range Max
25mm
Switch Terminals
Cable
Sensor Output
PNP, NC
Maximum Operating Temperature
+ 70 C
Supply Voltage
12 VDC to 24 VDC
Supply Current
15 mA
Output Voltage
2 V
Operating Supply Voltage
10 VDC to 40 VDC
Mounting Style
Bracket
Sensing Distance
3 mm to 25 mm
Minimum Operating Temperature
- 25 C
Current Rating
200 mA
Features
Permits non-contact detection of metallic and non-metallic objects, mounting bracket included
Voltage Rating
24 VDC
Sensor Type
Capacitive
Sensing Object
Metallic and Non-Metallic
Response Frequency
70Hz
Material - Body
ABS/PC
Shielding
Unshielded
Voltage - Supply
10 V ~ 40 V
Output Type
PNP-NC
Terminal Type
3-Wire
Package / Case
Cylinder
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Adjustable Long-distance Sensor
• Detects both metallic and nonmetallic objects (water, plastic, etc.).
• CE Marking for DC 3-Wire and AC/DC 2-Wire Models.
• Noise-resistant Models added to the lineup for application in a wide
Ordering Information
Sensors
Accessories (Order Separately)
Mounting Brackets
Standard Models
Noise-resistant Models
Appearance
range of industrial environments.
Long-distance type
E2K-C
Be sure to read Safety Precautions on
page 7.
[Refer to Dimensions on page 8.]
Y92E-A34
Appearance
Model
[Refer to Dimensions on page 8.]
Unshielded
Quantity
1
34 dia.
Provided with the product.
Sensing distance
Remarks
3 to 20 mm
3 to 25 mm
DC 3-wire, NPN
AC 2-wire
DC 3-wire, NPN
AC/DC 2-wire
Output configuration
E2K-C25ME1 2M
E2K-C25MY1 2M
E2K-C20MC1 2M
E2K-C20MT1 2M
Model
NO
Operation mode
CSM_E2K-C_DS_E_3_1
E2K-C25ME2 2M
E2K-C25MY2 2M
E2K-C20MC2 2M
E2K-C20MT2 2M
NC
1

Related parts for E2K-C25MF2

E2K-C25MF2 Summary of contents

Page 1

... Accessories (Order Separately) Mounting Brackets [Refer to Dimensions on page 8.] Appearance Model Quantity Y92E-A34 1 Sensing distance Output configuration DC 3-wire, NPN 2-wire DC 3-wire, NPN AC/DC 2-wire Remarks Provided with the product. CSM_E2K-C_DS_E_3_1 Model Operation mode NO NC E2K-C25ME1 2M E2K-C25ME2 2M E2K-C25MY1 2M E2K-C25MY2 2M E2K-C20MC1 2M E2K-C20MC2 2M E2K-C20MT1 2M E2K-C20MT2 2M 1 ...

Page 2

... Refer to Engineering Data on page 4. Operation indicator (red) Surge suppressor ±2% max. of sensing distance at the rated voltage in rated voltage +20%, −10% range at 100 VAC, ±20% range at 200 VAC 1,500 VAC, 50/60 Hz for 1 min between current-carrying parts and case E2K-C E2K-C25MY2 2 ...

Page 3

... VDC, 1.7 mA max. at 110 VAC (50/60 Hz), --- 2.5 mA max. at 250 VAC (50/60 Hz) Refer to Engineering Data on page 200 mA (resistive load) AC power max., DC power max. Refer to Engineering Data on page 4. 1,500 VAC, 50/60 Hz for 1 min between current-carrying parts and case 2 or greater to extend the cable. E2K-C E2K-C20MT2 --- --- 3 ...

Page 4

... A 40 VAC 30 Residual Load Voltage 20 10 OFF 100 200 250 Load current (mA) Sensing Distance Change by Sensing Object E2K-C25M E2K-C25MY at 200 VAC Residual output voltage ON 200 150 V Load 100 A 200 VAC 50 Residual Load Voltage OFF 100 200 Load current (mA) E2K-C20MT at 200 VAC ...

Page 5

... Load NO E2K-C20MC1 (between brown and black leads) Operation Indicator (yellow) Sensing object Load NC E2K-C20MC2 (between brown and black leads) Operation Indicator (yellow) Sensing Object Size vs. Sensing Distance E2K-C25M Grounded metal plate Square sensing 20 object Ungrounded X metal plate ( Phenolic resin plate ( ...

Page 6

... Load Reset ON Operation indicator (yellow) OFF Sensing Present object Not present Operate Load Reset Operation ON indicator (yellow) OFF E2K-C Output circuit Brown Load Proximity Sensor main circuit Blue Output circuit 24 to 240 VDC Brown 240 VAC Load Proximity Sensor main circuit ...

Page 7

... Indirect Detection To detect objects in metal containers, each metal container must have a nonmetallic window. Power ON Conditions Sensing is enabled within 200 ms for the E2K-C20M@@. Design the 80 mm system so that the power for the Sensor is turned ON before the min. power for the load. ...

Page 8

... Two, 5.5-dia. mounting holes The holes are not drilled completely through. Drill through the holes before using them. 45 57.6 E2K-C (Unit: mm) Screw hole for sensitivity adjustment - + Indicator Insulator diameter Models: Detection indicator (red Insulator diameter: Y Models: Operation indicator (red) Sensitivity adjuster E2K ...

Page 9

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords