Specifications of E2A-M30KS15-WP-C1-2M

Sensor Input
Inductive
Sensing Range
15mm
Sensor Housing
Cylindrical
Sensing Range Max
15mm
Mounting Type
M30
Switch Terminals
Cable
Overall Length
64mm
Sensor Output
NPN, NO
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Pre-wired Models (Shielded)
10
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
E2A-S08KS02-WP-@@
E2A-M18KS08-WP-@@
E2A-M30KS15-WP-@@
E2A-M12KS04-WP-@@
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
13
2. Operation indicator (yellow)
24
2. Operation indicator (yellow)
2. Operation indicator (yellow)
17
2. Operation indicator (yellow)
0.3 mm
0.3 mm
0.3 mm
36
0.3 mm
M8×1
2
2
; insulator diameter: 1.3 mm); standard length: 2 m
; insulator diameter: 1.3 mm); standard length: 2 m
2
E2A
M12×1
2
; insulator diameter: 1.3 mm); standard length: 2 m
; insulator diameter: 1.3 mm); standard length: 2 m
M18×1
3
27
M30×1.5
4
40
Cylindrical Proximity Sensor
Two, clamping nuts
4
34
5
Two, clamping nuts
50.3
39
5
Two, clamping nuts
Indicator (See note 2.)
59.5
7
10
44
(See note 1.)
Indicator (See note 2.)
Two, clamping nuts
64.5
Indicator (See note 2.)
10
(See note 1.)
(See note 1.)
Indicator (See note 2.)
(See note 1.)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
E2A-S08KN04-WP-@@
E2A-M18KN16-WP-@@
E2A-M12KN08-WP-@@
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
E2A-M30KN20-WP-@@
Pre-wired Models (Non-shielded)
13
2. Operation indicator (yellow)
2. Operation indicator (yellow)
Note 1. 4-dia. vinyl-insulated round cable with 3 conductors (conductor cross section:
2. Operation indicator (yellow)
17
0.3 mm
0.3 mm
24
36
0.3 mm
2. Operation indicator (yellow)
0.3 mm
6 dia.
2
2
; insulator diameter: 1.3 mm); standard length: 2 m
; insulator diameter: 1.3 mm); standard length: 2 m
9.4 dia.
2
; insulator diameter: 1.3 mm); standard length: 2 m
M8×1
15.3 dia.
2
26.6 dia.
; insulator diameter: 1.3 mm); standard length: 2 m
6
M12×1
7
3
27
M30×1.5
M18×1
10
4
40
34
15
Two, clamping nuts
5
50.3
4
39
Two, clamping nuts
7
Indicator (See note 2.)
44
5
59.5
Two, clamping nuts
10
64.5
Indicator (See note 2.)
(See note 1.)
Two, clamping nuts
10
Indicator (See note 2.)
(See note 1.)
Indicator (See note 2.)
(See note 1.)
(See note 1.)

Related parts for E2A-M30KS15-WP-C1-2M