Specifications of TL-M5ME1

Sensor Input
Inductive
Sensing Range
5mm
Supply Voltage Range Dc
10V To 30V
Sensing Range Max
5mm
Sensor Output
NO
Maximum Operating Temperature
+ 70 C
Operating Supply Voltage
10 V to 30 V
Sensing Distance
5 mm
Minimum Operating Temperature
- 25 C
Features
NO
Sensor Type
Inductive
Sensing Object
Metallic
Response Frequency
250Hz
Material - Body
ABS Resin
Shielding
Unshielded
Voltage - Supply
10 V ~ 30 V
Output Type
NPN-NO
Terminal Type
3-Wire
Package / Case
Box
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
TL-M5ME1
Manufacturer:
OMRON
Quantity:
1 000
As Easy To Install as a Microswitch
• A compact Proximity Sensor with the feel of a microswitch.
Ordering Information
Note: Models with different frequencies are also available. The model numbers are TL-M@M@@5 (e.g., TL-M2ME15).
Ratings and Specifications
Item
Sensing distance
Set distance
Differential travel
Detectable object
Standard sensing object
Response frequency
Power supply voltage
(operating voltage range)
Current consumption
Leakage current
Control
output
Indicators
Operation mode (with sens-
ing object approaching)
Protection circuits
Ambient temperature range
Ambient humidity range
Microswitch
type
Compact Proximity Sensor
TL-M
Appearance
Be sure to read Safety Precautions on
page 4.
Load current
Residual
voltage
Sensing distance
2 mm
Model
5 mm
2 mm ±10%
0 to 1.6 mm
10% max. of sensing distance
Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 2.)
Iron, 15 × 15 × 1 mm
E Models: 500 Hz, Y Models: 20 Hz
E Models: 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 20% max.
Y Models: 100 to 220 VAC (90 to 250 VAC), 50/60 Hz
E Models: 15 mA max. at 24 VDC (no-load)
Y Models: 2.5 mA max. at 200 VAC
E Models: 100 mA max. at 12 VDC, 200 mA max. at 24 VDC
Y Models: 10 to 200 mA
E Models: 1 V max.
Y Models: Refer to Residual Output Voltage under Engineering Data on page 3.
E Models: Detection indicator (red)
Y Models: Operation indicator (red)
E1/Y1 Models: NO
E2 Models: NC
E Models: Reverse polarity protection, Surge suppressor
Y Models: Surge suppressor
Operating/Storage: −25 to 70°C (with no icing or condensation)
Operating/Storage: 35% to 95% (with no condensation)
TL-M2ME1, TL-M2ME2, TL-M2MY1
DC 3-wire, NPN voltage output
DC 3-wire, NPN voltage output
Output specifications
Refer to the timing charts under I/O Circuit Diagrams on page 3 for details.
AC 2 wire
AC 2 wire
TL-M2ME1 2M
TL-M2MY1 2M
TL-M5ME1 2M
TL-M5MY1 2M
5 mm ±10%
0 to 4 mm
E Models: 250 Hz, Y Models: 20 Hz
NO
TL-M5ME1, TL-M5ME2, TL-M5MY1
Operation mode
Model
TL-M2ME2 2M
TL-M5ME2 2M
CSM_TL-M_DS_E_3_1
NC
---
---
1

Related parts for TL-M5ME1

TL-M5ME1 Summary of contents

Page 1

... DC 3-wire, NPN voltage output TL-M2ME1 wire TL-M2MY1 2M DC 3-wire, NPN voltage output TL-M5ME1 wire TL-M5MY1 ±10 Models: 250 Hz, Y Models Refer to the timing charts under I/O Circuit Diagrams on page 3 for details. CSM_TL-M_DS_E_3_1 Model Operation mode NO NC TL-M2ME2 2M --- TL-M5ME2 2M --- TL-M5ME1, TL-M5ME2, TL-M5MY1 1 ...

Page 2

... Power supply voltage (V) TL-M2MY1 2.5 2.0 Iron 1.5 Stainless steel (SUS304) 1.0 d × 0.5 Brass Aluminum Side length of sensing object: d (mm) TL-M TL-M5ME1, TL-M5ME2, TL-M5MY1 TL-M5M 6 Iron 5 d × Stainless steel (SUS304 Brass Aluminum Side length of sensing object: d (mm) 2 ...

Page 3

... Residual load OFF voltage 100 150 200 Load current (mA) I/O Circuit Diagrams DC 3-Wire Models Operation Output specifi- Model mode cations TL-M2ME1 NO TL-M5ME1 NPN TL-M2ME2 NC TL-M5ME2 AC 2-Wire Models Operation Model mode TL-M2MY1 NO TL-M5MY1 TL-M@MY1 at 200 VAC Residual Output Voltage 200 VAC A 50 ...

Page 4

... Safety Precautions Refer to Warranty and Limitations of Liability. WARNING This product is not designed or rated for ensuring safety of persons either directly or indirectly. Do not use it for such purposes. Precautions for Correct Use Do not use this product under ambient conditions that exceed the ratings. ● Design ...

Page 5

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...

Related keywords