Page 1
Solid State Relays G3PA Extremely Thin Relays Integrated with Heat Sinks • Downsizing achieved through optimum design of heat sink. • Mounting possible via screws or via DIN track. • Close mounting possible for linking terminals. (Except for G3PA-260B-VD and ...
Page 2
... G32A-A20-VD AC24 G32A-A40-VD DC5-24 G32A-A40L-VD DC5-24 G32A-A40-VD AC24 G32A-A60-VD DC5-24 G32A-A60L-VD DC5-24 G32A-A60-VD AC24 G32A-A420-VD DC12-24 G32A-A430-VD DC12-24 G32A-A420-VD-2 DC12-24 G32A-A430-VD-2 DC12-24 G32A-A450-VD-2 DC12-24 Voltage level Must release voltage 1 VDC min. 4.8 VAC min. 1 VDC min. Inrush current 150 A (60 Hz, 1 cycle) ...
Page 3
Characteristics Item G3PA- G3PA- 210B(L)-VD 220B(L)-VD Operate time 1/2 of load power source cycle + 1 ms max. (DC Input, -B models) 1 1/2 of load power source cycle + 1 ms max. (AC Input max. (-BL ...
Page 4
... G32A-A Power Device Cartridge The G32A-A Power Device Cartridge (a Triac Unit) can be replaced with a new one. When the temperature indicator has changed from pink to red, the triac circuitry may have malfunctioned possibly by an excessive flow of current, in which case, dismount the damaged cartridge for replacement. ...
Page 5
... Apply silicone grease (provided with the G32A-A) to the entire surface of the heat sink. G32A-A40(L)-VD/G32A-A60(L)-VD/G32A-A430-VD(-2)/G32A-A450-VD-2 The G32A Power Device Cartridge is mounted and secured with screws to the G3PA Unit. Extraction Follow the procedures below to remove the G32A-A Power Device Cartridge from the G3PA. ...
Page 6
... N•m. 6. Attach the terminal cover. Side A 7. Switch on the power and check the G3PA to be sure it works properly. Side B • Connecting with linking terminal to “G32A-D” series short circuit unit. (Order short circuit units seperately.) SSR1 SSR2 SSR G32A Unit terminal securely 1 ...
Page 7
Engineering Data Load Current vs. Ambient Temperature Vertical Mounting Panel Ground G3PA-210B(L)-VD, G3PA-220B(L)-VD G3PA-220B(L)-VD 25 G3PA-210B(L)-VD 15 Ambient temperature (°C) G3PA-420B-VD, G3PA-420B-VD-2 Ambient temperature (°C) Note: Close mounting is possible for a maximum of three Units by reducing the load ...
Page 8
Input Voltage vs. Input Current G3PA-2@0B- 25° Input current 2 1 0.8 Input impedance 0.6 0.4 0.2 0 Input voltage (V) Horizontal Mounting Panel Ground G3PA-210B(L)-VD, G3PA-220B(L)-VD ...
Page 9
Close Mounting (Up to Three) Panel Ground DIN track G3PA-210B(L)-VD, G3PA-220B(L)- G3PA-220B- G3PA-210B- 4.5 Ambient temperature (°C) G3PA-420B-VD, G3PA-420B-VD − Ambient temperature (°C) G3PA-450B-VD-2 ...
Page 10
Inrush Current Resistivity One cycle, non-repetitive (Keep the inrush current to half the rated value if it occurs repetitively.) G3PA-210B(L)-VD Energized time (ms) G3PA 446 Solid State Relays G3PA-220B(L)-VD, G3PA-420B-VD, G3PA-420B-VD-2 Energized time (ms) G3PA-240B(L)-VD/260B(L)-VD, G3PA-430B-VD, G3PA-430B-VD-2, G3PA-450B-VD-2 Energized time ...
Page 11
Dimensions Note: All units are in millimeters unless otherwise indicated. G3PA-210B(L)-VD Without Terminal Cover Two, M4 Linking terminal B1 Two, M3.5 Linking terminal B2 4.6 x 5.6 elliptical hole G3PA-220B(L)-VD Without Terminal Cover Two, M4 Linking terminal B1 Linking terminal ...
Page 12
G3PA-260B(L)-VD With Terminal G3PA-450B-VD-2 Cover 4.6 x 5.6 elliptical hole 100 max. G3PA-420B-VD, G3PA-420B-VD-2 Without Terminal Cover Two, M4 7.6 Linking terminal 100 38 67 +B1 max. Linking terminal −B2 8.6 Two, M3.5 2.2 4.5 x 5.6 elliptic hole 8.8 ...
Page 13
Safety Precautions ■ Precautions for Correct Use Please observe the following precautions to prevent failure to oper- ate, malfunction, or undesirable effect on product performance. Load Connection For an AC load, use a power supply rated ...
Page 14
Close Mounting SSR Mounting Pitch Panel Mounting (At a rated ambient temperature of 40°C). Duct or airflow obstruction SSR Mounting direction Vertical direction 80 mm min. Space between Close Mounting SSRs min. Relationship between SSRs and Ducts Countermeasure (1) Duct ...
Page 15
... Complete “Terms and Conditions of Sale” for product purchase and use are on Omron’s website at http://www.components.omron.com – under the “About Us” tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. ...
Page 16
... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...
Page 17
... São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS MEXICO • HEAD OFFICE Apodaca, N.L. • 52.811.156.99.10 • 001.800.556.6766 • mela@omron.com OMRON EUROpE B.V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands. Tel: +31 (0) 23 568 13 00 Fax: +31 (0) 23 568 13 88 www.industrial.omron.eu Cat. No. J26I-E-01 06/09 OMRON ARGENTINA • ...