DF19G-20S-1SD-GND Hirose Electric Co Ltd, DF19G-20S-1SD-GND Datasheet - Page 13

CONN GROUND PLATE COAXIAL 20POS

DF19G-20S-1SD-GND

Manufacturer Part Number
DF19G-20S-1SD-GND
Description
CONN GROUND PLATE COAXIAL 20POS
Manufacturer
Hirose Electric Co Ltd
Series
DF19r
Type
Ground Plater
Datasheet

Specifications of DF19G-20S-1SD-GND

Number Of Positions
20
For Use With/related Products
DF19 Connectors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
*DF19G-20S-1SD-GND
H3118
The product information in this catalog is for reference only. Please request the Engineering Drawing for the most current and accurate design information.
All non-RoHS products have been discontinued, or will be discontinued soon. Please check the products status on the Hirose website RoHS search at www.hirose-connectors.com, or contact your Hirose sales representative.
B
Note 1: The grounding plate and the plug are supplied as separate components.
Note 2: Dedicated assembly fixtures are required at each stage of the termination process. For detail, refer to the instruction manual
Note 3: Do not apply excessive forces to FPC (Bending or twisting) as it may introduce cracks in the copper foil (on the cover film edge).
Note 4: To protect the FPC, insertion and disconnection of the connectors should be performed parallel to the mating direction.
Note 5: Do not apply excessive tension to FPC.
Note 6: Refer to FPC manufacturer for bend radius and other specific recommendation. Distance should be allowed for the bending
Note 7: Follow the instruction manuals for the termination and assembly fixtures and tools.
Plug (FPC Type) Termination Procedures
(Dedicated Assembly Tooling is required.)
supplied with the tools.
position, as illustrated below.
Final
completion
Step 1
Step 2
Step 3
Step 4
After passing through, lower the FPC (as shown) to horizontal position.
DF19 Series●1 mm Contact Pitch, Board-to-Cable, Board-to-FPC, Board-to-Micro-coaxial Cable Connectors
Insert the FPC diagonally from the top surface of the grounding plate.
Assembly point: Slightly raise the FPC to an angle of about 30 degrees,
and then insert the grounding plate over the socket.
Extend the FPC out and fully insert into the socket.
Pass the FPC through the grounding plate.
Exercising caution slide the grounding plate forward and pre-insert it over the socket.
Ground surface
Signal surface
SIGNAL
Using the dedicated installation tool, insert the grounding plate.
B265

Related parts for DF19G-20S-1SD-GND