Item
These refer to the direction of the test results. In Far End Source mode, the tester assigns END 1-2 to the
results if THIS END on the Job tab in Setup is set to END 2, or END 2-1 if THIS END is set to END 1.
PASS: The measurement in the column is within the limit.
FAIL: The measurement in the column exceeds the limit.
The loss of the fiber. "Too High" is shown if the loss is too high to measure. If loss is negative, set the
reference and test the cabling again. See Table 7-10 for details.
The maximum loss allowed by the selected test limit.
The difference between the limit and the measured value. Margin is negative for measurements that fail.
The results show N/A for values not defined by the selected test limit.
Table 7-9. Far End Source Mode RESULTS Screen Features
Description
Testing in Far End Source Mode
Using the Loss/Length Option
7-35
7