1601750000 Weidmuller, 1601750000 Datasheet - Page 26

no-image

1601750000

Manufacturer Part Number
1601750000
Description
HDC-C-HD-SMO.75-100AG 100/PK
Manufacturer
Weidmuller
Series
Rockstar® HDr
Type
Machined (Turned, Solid)r
Datasheet

Specifications of 1601750000

Pin Or Socket
Pin
Contact Termination
Crimp
Wire Gauge
18 AWG
Contact Finish
Silver
Contact Finish Thickness
118.1µin (3.00µm)
Connector Type
Contact, Crimp
Contact Plating
Silver
Contact Material
Copper
Contact Gender
Pin
Wire Size (awg)
18
Gender
Pin
Rohs Compliant
Yes
For Use With
1650574444 - CONN MALE INSERT HD SIZE 1 7POS1862050000 - CONN MALE INSERT W/LEVER 10POS1758400000 - HDC-CM-10SCM GREY1682120000 - HDC-CM-10SCM1651280000 - HDC-HDD-108SCM109-2161651240000 - HDC-HDD-72SCM73-1441651210000 - HDC-HDD-108SCM1651190000 - HDC-HDD-72SCM1651170000 - HDC-HDD-42SCM1651150000 - HDC-HDD-24SCM281-2288 - CONN MALE INSERT HD SIZE 4 24POS281-2292 - CONN MALE INSERT HD SIZE 5 25POS281-2286 - CONN MALE INSERT HD SIZE 3 16POS1650650000 - HDC-HD-15SCM281-2283 - CONN MALE INSERT HD SIZE 1 8POS281-2281 - CONN MALE INSERT HD SIZE 1 7POS1601720000 - HDC-HD-64 SCM1601710000 - HDC-HD-40SCM
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
A
Technical data
Electrical data
Design of clearances and creepage distances in
electrical equipment
General
Since April 1997 the sizing of clearances and creepage dis-
tances has been covered by DIN VDE 0110, part 1 “Insulation
coordination for electrical equipment in low-voltage systems”.
DIN VDE 0110, part 1 contains the modified edition of IEC
Report 664-1 (see also IEC 664-1/Oct 1992). Since April 2003,
the rules of DIN EN 60664-1 / 11.03 in conjunction with DIN 61984
/ 09.02 apply to the dimensioning of clearances and creepage
distances.
The design data resulting from these provisions is – if applicable
– specified in this catalogue for each product.
For the design of clearances and creepage distances, applica-
tion of the regulations for insulation coordination produces the
following interrelationships:
Clearances
Clearances are rated in accordance with the following factors:
• Anticipated overvoltage
• Used
• Measures to prevent pollution
A.16
rated impulse withstand voltage
overvoltage protection precaution
pollution severity
Creepage distances
Creepage distances are rated in
accordance with the following factors:
• Planned
• Insulation materials used
• Measures to prevent pollution
Slots are taken into account when measuring creepage dis-
tances if their minimum width X is dimensioned according to
the following table:
Pollution severity
1
2
3
4
If the associated clearance in air is less than 3 mm, the
minimum slot width can be reduced to 1/3 of the
clearance.
rated voltage
insulation group
pollution severity
Minimum width X
in mm
0.25
1.0
1.5
2.5

Related parts for 1601750000