TO-2-1/V/SVB MOELLER, TO-2-1/V/SVB Datasheet

ISOLATOR, INTERLOCK, 20A, 3POLE

TO-2-1/V/SVB

Manufacturer Part Number
TO-2-1/V/SVB
Description
ISOLATOR, INTERLOCK, 20A, 3POLE
Manufacturer
MOELLER
Series
T0r
Datasheet

Specifications of TO-2-1/V/SVB

No. Of Poles
3
Contact Voltage Ac Max
690V
Contact Current Ac Max
20A
Svhc
No SVHC (18-Jun-2010)
Approval Bodies
UL, CSA
Current Rating
20A
Ip/nema Rating
IP55
Power Rating
13kW
Lead Free Status / RoHS Status
na
Type: T0−2−1/V/SVB
Article No.: 043619
Sales text ON−OFF SWITCH
1
Ordering information
Produktgruppen−Bezeichnung
Design
Basic type for ... insert mounting form
Mounting form
No. of poles
Description
General
Standards
Lifespan, mechanical
Maximum operating frequency
Climatic proofing
Operations/h
Operations
M
× 10
BME−CAT Fotos
T0−...
Load current switches
Main switches, maintenance
switches
Rear mounting
T0−2−1/...
V/SVB
3
As Emergency−Stop device
6
IEC/EN 60947, VDE 0660,
IEC/EN 60204, CSA, UL
Switch−disconnectors to
IEC/EN 60947−3
Load−break switches to
IEC/EN 60947−3
1
3000
Damp heat, constant, to IEC
60068−2−78; Damp heat,

Related parts for TO-2-1/V/SVB

TO-2-1/V/SVB Summary of contents

Page 1

... Main switches, maintenance switches Rear mounting T0−2−1/... V/SVB Emergency−Stop device IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL Switch−disconnectors to IEC/EN 60947−3 Load−break switches to IEC/EN 60947−3 6 Operations × Operations/h 3000 Damp heat, constant, to IEC 60068−2−78; Damp heat, ...

Page 2

... Load rating with intermittent operation, class Short−circuit rating Fuse Rated short−time withstand current (1 s current) Safe isolation to VDE 0106 Part 101 and Part 101/A1 between the contacts Switching angles Contact units Double−break contacts Current heat loss per contact ...

Page 3

... Rated breaking capacity, motor load switch cos = 0.35 230 V 400 V 500 V 690 V Rated operational current 440 V load−break switch AC−21A AC−3 motor load switch motor rating 230 V 230 V Star−delta 400 V 400 V Star−delta 500 V 500 V Star−delta 690 V 690 V Star−delta AC− ...

Page 4

... Rated operational current 240 V 240 V Contacts DC−23A, motor load switch L Rated operational current Contacts 48 V Rated operational current Contacts 60 V Rated operational current Contacts 120 V Rated operational current Contacts 240 V Rated operational current Contacts DC−13, Control switches L Rated operational current Voltage per contact pair in series ...

Page 5

... Dimensions Extension can be extended using ZVV−T0 + ZAV−T0, max. 4 × 100 mm not included Depth of a contact unit: 9.5 mm Dimensions Diameter of drilled hole Bottom Dimensions 5 cross−section size difference admissible between 2 conductors For type T8−3−8342/... the following applies: switching angle = 90° and flat connection = 1 busbar 25 × ...

Page 6

... Diameter of drilled hole Door Dimensions 3 padlocks Characteristic curve For utilisation category AC−4 (extreme load: 100 % inching, reversing or plugging) The blocked rotor current of the motor should not exceed the rated current of the switch for AC−21A to ensure a reasonable device lifespan. 6 ...

Page 7

... Moeller GmbH, Hein−Moeller−Str. 7−11, D−53115 Bonn E−Mail: catalog@moeller.net, Internet: www.moeller.net, http://catalog.moeller.net HPL−C2007G V2.1 © 2007 by Moeller GmbH 7 ...