Optical Fiber Cable
4-6
4-7
Increasing Cable Length
Connector Attachment
Note
When installed in a rack or trough, secure the cable with mounting brackets or
saddles to prevent movement. Be sure not to attach the brackets or saddles too
tightly, because excessive compression will damage the cable.
Use a bushing with a rubber ring, saddle, etc., to secure the cable to the wall of
the housing or panel where the cable ends. If the bushing or saddle is too large
for the cable, wrap a strip of rubber or a few layers of PVC tape so it fits snugly.
Leave 2 to 3 m of slack in the cable if connectors are being attached on site.
Take up any slack from the tension member and fasten it securely. The tension
member’s metal fastener must be properly grounded. Always secure the tension
member.
In general, an Optical Fiber Cord or Cable that is not long enough should be re-
placed with a cord or cable of sufficient length.
When a cord or cable is installed in a trough or rack, the connection point is in-
doors and accessible, and an increase in signal loss of 1.5 dB is acceptable, an
extension cable can be connected with an inline adapter. Transmissions with
two cables connected by an inline adapter are less reliable than transmissions
through a single cable.
Use of an inline adapter in conduit, duct, or elevated installation should be
avoided because of reliability concerns.
Refer to the manual included with the S3200-CAK1062 Optical Connector As-
sembly Tool Kit for information regarding the attachment of connectors to Opti-
cal Fiber Cords and Cables.
1. Protect the end of the cable with conduit if the exposed cable is in a location
2. If conduit is used, insert a bushing at the end of the conduit and use saddles
Optical Fiber
Cable
where it might be stepped on or damaged accidentally.
or guides to prevent the cable from being bent at too severe an angle.
Housing wall or panel
Anchor
bushing
50
Cable end
Optical Fiber Cord
(Leave some slack.)
Tension member fastener
Connector
Section 4-7
Optical
Transceiver
Optical
Transceiver