C500RT201 Omron, C500RT201 Datasheet - Page 118

no-image

C500RT201

Manufacturer Part Number
C500RT201
Description
WRITE SLAVE
Manufacturer
Omron
Datasheet

Specifications of C500RT201

Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
When Using CS1-series PCs
Auxiliary Area
Allocations in the CIO Area
No CIO Area words are used.
Allocations in the DM Area
No DM Area words are used.
Hardware Setup
110
SYSMAC BUS Error
Flag
(Non-fatal error)
SYSMAC BUS Master
Error Flags
Slave Number of
SYSMAC BUS Error
After Startup
SYSMAC BUS Slave
Number Refresh Bit
Name
1, 2, 3...
A40205
A40500 to A40501
A42504 to A42506
A42504 only
A42508 to A42515
A50900
CS1
1. Mount a Remote I/O Master Unit to a CS1 CPU Rack, a C200H I/O Expan-
2. Set the unit number of the Master using the unit number switch on the front,
3. Set the unit number, the Output HOLD/STOP Mode, and the type of master
4. Set the unit numbers for Slaves other than Slave Units.
5. Perform connections using 2-conductor cable.
6. Set the terminator.
7. Connect a Programming Device to the PC.
sion Rack, or a CS1 Expansion Rack (not a SYSMAC BUS Remote I/O
Slave Rack). Up to two Masters can be mounted for a basic system. (There
are no restrictions on the mounting position.)
and set the CONTINUE/STOP switch as required.
for each of the Slave Units.
On when a transmission error occurs in a
data transfer in the SYSMAC BUS system.
The number of the Master involved is
indicated with bits A40500 and A40501.
When an error occurs in the SYSMAC BUS
system, the flag for the affected Master Unit
will be turned ON.
A40500: Flag for Master Unit #0
A40501: Flag for Master Unit #0
When there is an error in a Slave Rack, these
bits contain the slave’s unit number.
When there is an error in an Optical I/O Unit
(excluding Slave Racks), the status of
A42504 (0 or 1) indicates whether the Unit is
low or high.
When there is an error in a Slave Rack, this
byte contains the 2-digit hexadecimal unit
number of the Master to which the Slave is
connected.
(B0 Hex: Master Unit 0; B1 Hex: Master Unit
1)
When there is an error in an Optical I/O Unit,
this byte contains the 2-digit hexadecimal unit
number.
(00 to 1F hexadecimal, or 0 to 31 decimal)
Turn this bit ON to refresh the error
information in A425 (unit number of Slave
where error occurred after startup).
Description
C200H/HX/HG/HE/HS
SR 25312
SR 25104 to
SR 25115
AR 0200 to AR 0204
correspond to unit
numbers #0 to #4.
SR 25103
Whether the Unit is
low or high is
indicated in AR 03 to
AR 06.
AR 0015: Error in unit
number #0
AR 0014: Error in unit
number #1
AR 03 to AR 06:
These flags turn ON
when there is an error
in the Unit with
corresponding unit
number and status
(L/H).
SR 25100
Corresponding bits
Appendix C
in