CV500-MC421 Omron, CV500-MC421 Datasheet - Page 56
![no-image](/images/manufacturer_photos/0/4/494/omron_sml.jpg)
CV500-MC421
Manufacturer Part Number
CV500-MC421
Description
SERVO CONTROL MODULE
Manufacturer
Omron
Datasheet
1.CV500-MC221.pdf
(72 pages)
Specifications of CV500-MC421
Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Available stocks
Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
CV500-MC421
Manufacturer:
SEEQ
Quantity:
101
2. Turning the Servo ON
3. Setting the Voltage of Speed Command Input to 0 V
4. Setting the Direction that Provides Offset
5. Adjusting Offset
6. Closing the Speed Command Manual Zero Adjustment Window
Speed Command Manual Zero Adjustment window opens.
Input the Run signal (ON). When bit No. 0 of setup parameter No. 1 is set to “1,” this operation is not
required.
Type voltage of speed command input (REF) with which the number of rotations becomes zero
(normally 0 V).
Select [Up] (providing offset on positive side) or [Down] (providing offset on negative side).
Adjust the offset so that motor or machine stops completely.
Move the mouse cursor over [Up] or [Down].
Select [Up] or [Down] using the Tab Key.
Click on [Up] or [Down]. The offset value increases or decreases by 1 for every click.
Press the Space Key. The offset value increases or decreases by 1 each time the Space Key is
pressed.
Click on [ ] in the upper-left part of the window.
Press the Escape Key.
Chapter 5