Specifications of E53-CN03N2

Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Temperature Accuracy ±
0.3%
Mounting Type
DIN Panel
Approval Bodies
CULus, CE
For Use With
E5CN Temperature Controller
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Upgraded 1/16, 1/8, and 1/4 DIN Controllers, the Best-selling E5@N Series.
Basic Type (Renewal E5@N) and Advanced Type (New E5@N-H).
• Improved indication accuracy and preventive maintenance (Basic Type E5@N).
• New high-performance Controllers (Advanced Type E5@N-H).
• Easy-to-use one-touch operation with PF Key (Only for 1/8 and 1/4 DIN).
• Logic operations.
Digital Temperature Controllers/Digital Controllers
E5@N/E5@N-H
1/16 DIN
E5CN
Basic Type (Renewal E5@N)
1/8 DIN
E5EN
1/4 DIN
E5AN
E5@N Series
1/16 DIN
E5CN-H
Advanced Type (New E5@N-H)
E5EN-H
1/8 DIN
E5AN-H
1/4 DIN
1 1

Related parts for E53-CN03N2

E53-CN03N2 Summary of contents

Page 1

Digital Temperature Controllers/Digital Controllers E5@N/E5@N-H Upgraded 1/16, 1/8, and 1/4 DIN Controllers, the Best-selling E5@N Series. Basic Type (Renewal E5@N) and Advanced Type (New E5@N-H). • Improved indication accuracy and preventive maintenance (Basic Type E5@N). • New high-performance Controllers (Advanced ...

Page 2

Digital Temperature Controllers Digital Controllers Operation Procedure Common to All Controllers CX-Thermo Support Software 2 Contents E5CN/E5CN-U ............................................. E5AN/E5EN ................................................. E5CN-H........................................................ E5AN-H/E5EN-H.......................................... • Operation ..................................................... • Safety Precautions ....................................... • EST2-2C-MV4.............................................. ...

Page 3

Basic-type Digital Temperature Controller E5CN/E5CN-U New 48 x 48-mm Basic Temperature Controller with Enhanced Functions and Performance. Improved Indication Accuracy and Preventive Maintenance Function. Indication Accuracy Thermocouple input: ±0. (previous models: ±0.5%) Pt input: ±0. (previous ...

Page 4

... Terminal Cover -500: With terminal cover Note: Not all combinations of function 1 and function 2 specifications are possible for Option Units (E53-@@@@). ✽1. Always connect an AC load to a long-life relay output. The output will not turn OFF load is connected because a triac is used for switching the circuit. For details, check the conditions in Ratings. ✽ ...

Page 5

... E5CN-R2MLD-500 E5CN-Q2MLD-500 E5CN-C2MLD-500 E5CN-RMT-W-500 E5CN-QMT-W-500 E5CN-CMT-W-500 E5CN-R2MT-W-500 E5CN-Q2MT-W-500 E5CN-C2MT-W-500 E5CN-Y2MT-W-500 E5CN-R2MTD-W-500 E5CN-Q2MTD-W-500 E5CN-C2MTD-W-500 Model E53-CNHH03N2 E53-CNHBN2 E53-CNQ03N2 External power supply for E53-CNPBN2 ES1B External power supply for E53-CNPHN2 ES1B External power supply for E53-CNP03N2 ES1B E53-CNH03N2 E53-CN03N2 E53-CNBN2 E53-CNQHN2 E53-CNQHHN2 E53-CNQBN2 5 ...

Page 6

E5CN/E5CN-U Model Number Structure Model Number Legend (Plug-in-type Controllers) E5CN-@@@ Output Type R: Relay output Q: Voltage output (for driving SSR) C: Current output 2. Number of Alarms Blank: No alarm 1: One alarm 2: ...

Page 7

... USB-Serial Conversion Cable Model E58-CIFQ1 Terminal Cover Connectable models Terminal block models Model E53-COV17 Note: The Terminal Cover comes with the E5CN-@@@-500 models. Waterproof Packing Model Y92S-29 Note: The Waterproof Packing is included with the Controller only for models with terminal blocks. ...

Page 8

E5CN/E5CN-U Specifications Ratings model number: 100 to 240 VAC, 50/60 Hz Power supply voltage D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage 100 to 240 ...

Page 9

Input Ranges Thermocouple/Platinum Resistance Thermometer (Universal Inputs) Input Platinum resistance Type thermometer Name Pt100 JPt100 K 2300 1800 1700 1600 1500 1400 1300 1300 1200 1100 1000 850 900 800 700 600 500.0 500.0 500.0 500 400 300 200 100.0 ...

Page 10

E5CN/E5CN-U Alarm Outputs Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit. Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also ...

Page 11

... When robust tuning (RT) is ON, the differential time is 0.0 to 999.9 (in units of 0.1 s). ✽6. External communications (RS-485) and cable communications for the Setup Tool can be used at the same time. ✽7. The E5CN-U plug-in model is certified for UL listing only when used together with the OMRON P2CF-11 or P2CF-11-E Socket. The P3GA-11 is not certified for UL listing. ...

Page 12

E5CN/E5CN-U USB-Serial Conversion Cable Applicable OS Windows 2000, XP, or Vista Thermo Mini, CX-Thermo version 4.0 or Applicable software higher E5AN/E5EN/E5CN/E5CN-U/E5AN-H/ Applicable models E5EN-H/E5CN-H USB interface standard Conforms to USB Specification 1.1. DTE speed 38400 bps Computer: USB (type A ...

Page 13

... Option Units E53-CNHH03N2 E53-CNHBN2 Communications Event inputs (RS-485) and CT2 and CT B(+) 11 11 RS-485 EV1 13 13 EV2 CT2 14 14 CT1 CT1 15 15 E53-CNH03N2 E53-CN03N2 Communications Communications (RS-485) and CT (RS-485) B(+) B(+) 11 11 RS-485 RS-485 NOT NOT USE USE 14 DO NOT 14 CT1 USE ...

Page 14

... Temperature unit Level Key Mode Key Down Key 1.5 58 44.8 44.8 48.8 Waterproof Mounting Adapter Terminal Cover Packing (Accessory) (E53-COV17) (Accessory) (Accessory) Note: The terminal block cannot be removed. (84.7) 14.2 6 70.5 58 44.8 44.8 Mounting Adapter (Accessory) LED indicator (SD) 250 USB connector (type A plug) No ...

Page 15

... Terminal Cover E53-COV17 Note: The E53-COV10 cannot be used. 48 48.8 22 9.1 Current Transformers E54-CT1 E54-CT3 E54-CT3 Accessory Armature Connection Example Plug Approx. 3 dia. 18 Plug Approx. 6 dia. (22) Waterproof Packing Y92S-29 (for DIN 48 48) Order the Waterproof Packing separately if it becomes lost or damaged. The Waterproof Packing can be used to achieve an IP66 degree of protection ...

Page 16

E5CN/E5CN-U Adapter Y92F-45 Note: Use this Adapter when the panel has already been prepared for the E5B@. Mounted to E5CN E5CN-U Wiring Socket Front-connecting Socket Eleven, M3.5 P2CF-11 sems screws 70 max max. Note: A model with finger ...

Page 17

Basic-type Digital Temperature Controller E5AN/E5EN New 96 x 96-mm and 48 x 96-mm Basic Temperature Controllers with Enhanced Functions and Performance. Improved Indication Accuracy and Preventive Maintenance Function. Indication Accuracy Thermocouple input: ±0. (previous models: ±0.5%) Pt input: ...

Page 18

... Case Color Blank: Black W: Silver 8. Terminal Cover -500: With terminal cover 9. Version N: Available only to models released after January 2008. 18 Temperature input Analog input Option Units E53 Function EN01: RS-232C communications EN03: RS-485 communications AKB: Event input 3 auxiliary outputs 1 control output 2 control outputs ...

Page 19

Ordering Information E5AN Controllers with Terminal Blocks Power Case Size supply Input type color voltage Thermocouple or Resistance thermometer 100 to 240 VAC Black 1/4 DIN Analog ( (current/voltage) Thermocouple 24 VAC/ or VDC Resistance ...

Page 20

E5AN/E5EN E5EN Controllers with Terminal Blocks Power Case Size supply Input type color voltage Thermocouple or Resistance thermometer 100 to 240 VAC Black 1/8 DIN Analog (current/volt- age) Thermocouple 24 VAC/ or VDC Resistance ...

Page 21

... Note: The Waterproof Packing is included with the Controller. Function RS-232C communications RS-485 communications Event inputs Current Transformers (CTs) Hole diameter 5.8 dia. 12.0 dia. CX-Thermo Support Software Model Model Y92S-P4 Y92S-P5 E5AN/E5EN Model E53-EN01 E53-EN03 E53-AKB Model E54-CT1 E54-CT3 Model EST2-2C-MV4 21 ...

Page 22

E5AN/E5EN Specifications Ratings model number: 100 to 240 VAC, 50/60 Hz Power supply voltage D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage Power 100 to ...

Page 23

Input Ranges Thermocouple/Platinum Resistance Thermometer (Universal inputs) Input Platinum resistance type thermometer Name Pt100 JPt100 K 2300 1800 1700 1600 1500 1400 1300 1300 1200 1100 1000 850 900 800 700 600 500.0 500.0 500.0 500 400 300 200 100.0 ...

Page 24

E5AN/E5EN Alarm Outputs Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit. Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also ...

Page 25

Characteristics Thermocouple: ( 0.3% of indicated value whichever is greater) 1 digit max. ✽1 Platinum resistance thermometer: ( 0.2% of indicated value or 0.8 C, whichever is greater) 1 digit max. Indication accuracy Analog input: 0.2% FS ...

Page 26

E5AN/E5EN USB-Serial Conversion Cable Applicable OS Windows 2000, XP, or Vista Thermo Mini, CX-Thermo version Applicable software 4.0 or higher E5AN/E5EN/E5CN/E5CN-U/E5AN- Applicable models H/E5EN-H/E5CN-H USB interface standard Conforms to USB Specification 1.1. DTE speed 38400 bps Computer: USB (type A ...

Page 27

... USE DO NOT 17 USE A DO NOT DO NOT 18 USE USE NOT B 20 USE TC/Pt multi-input Analog input E5AN/E5EN Communications E53-EN01 E53-EN03 E53-AKB RS-232C RS-485 Event inputs EV2 NOT USE CT1/CT2 A heater burnout alarm, heater short alarm, heater overcurrent alarm, or input alarm is sent to the output to which the alarm 1 function is assigned ...

Page 28

... PV No.1 display SV No. 2 display MV No. 3 display Up Key Down Key Mode Key Mounted Separately 6 79 120 min. Terminal Cover Mounting Bracket (E53-COV16) (Accessory) (Accessory) Crimp terminal size: M3.5 Operation indicators SUB1 SUB2 HA SUB3 PV Temperature unit No.1 display SV No.2 display OUT1 STOP MV No.3 display ...

Page 29

... E5EN 48 96 Accessories (Order Separately) USB-Serial Conversion Cable E58-CIFQ1 USB connector (type A plug) Terminal Covers E53-COV16 (Six Covers provided.) 6 79.2 2 112 91 Terminal Cover (E53-COV16) Waterproof Mounting Bracket (Accessory) Packing (Accessory) (Accessory) Crimp terminal size: M3.5 250 LED (SD) 1.2 3.2 10 44.8 E5AN/E5EN ...

Page 30

... IP66. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Waterproof Packing does not need to be attached if a waterproof structure is not required ...

Page 31

Advanced Digital Temperature Controller E5CN-H A New High-performance Controller: High Resolution, High Speed, and High Input Accuracy. Logic Operations and Preventive Maintenance Function. High-resolution display with 5 digits/0.01 C display in a compact Controller ( mm). High-speed sampling ...

Page 32

... Blank: 100 to 240 VAC D: 24 VAC/VDC 6. Case Color Blank: Black W: Silver 7. Terminal Cover -500: With terminal cover Note: Not all combinations of function 1 and function 2 specifications are possible for Option Units (E53-@@@@). 32 1 control output Fully universal input 2 control outputs Option Units E53-@@@@ ...

Page 33

... E5CN-H Control output 1 Model E5CN-HR2M-500 E5CN-HQ2M-500 E5CN-HC2M-500 E5CN-HV2M-500 E5CN-HR2MD-500 E5CN-HQ2MD-500 E5CN-HC2MD-500 E5CN-HV2MD-500 E5CN-HR2M-W-500 E5CN-HQ2M-W-500 E5CN-HC2M-W-500 E5CN-HR2MD-W-500 E5CN-HQ2MD-W-500 E5CN-HC2MD-W-500 Model E53-CNHH03N2 E53-CNHBN2 E53-CNQ03N2 E53-CNH03N2 E53-CN03N2 E53-CNBN2 E53-CNQHN2 E53-CNQHHN2 E53-CNQBN2 Transfer Output E53-CNQFN2 Transfer Output E53-CNBFN2 E53-CNQ01N2 E53-CN01N2 E53-CNH01N2 Model Y92F-45 Model EST2-2C-MV4 33 ...

Page 34

E5CN-H Specifications Ratings model number: 100 to 240 VAC, 50/60 Hz Power supply voltage D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage 100 to 240 ...

Page 35

Input Ranges Thermocouple/Platinum Resistance Thermometer/Analog Input (Fully Universal Inputs) Platinum resistance Input type thermometer Name Pt100 JPt100 2300 1800 1700 1600 1500 1400 1300.0 1300 1200 1100 1000 850.0 900 800 700 600 500.0 500.0 500.0 500 400 300 200.00 ...

Page 36

E5CN-H Alarm Outputs Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit. Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also ...

Page 37

Characteristics Thermocouple: ( 0.1% of indicated value whichever is greater) 1 digit max. ✽1 Platinum resistance thermometer: ( 0.1% of indicated value or 0.5 C, whichever is greater) 1 digit max. Indication accuracy Analog input: 0.1% FS ...

Page 38

E5CN-H USB-Serial Conversion Cable Applicable OS Windows 2000, XP, or Vista Thermo Mini, CX-Thermo version Applicable software 4.0 or higher E5AN/E5EN/E5CN/E5CN-U/ Applicable models E5AN-H/E5EN-H/E5CN-H USB interface standard Conforms to USB Specification 1.1. DTE speed 38400 bps Computer: USB (type A ...

Page 39

... Control Output 2 and and CT2 Transfer Output 11 11 Control output 2 Control output 2 12 VDC VDC NOT 13 13 USE CT2 14 14 CT1 Transfer output 15 15 E53-CN03N2 E53-CNQ03N2 Communications Communications (RS-485) (RS-485) and Control Output RS-485 RS-485 NOT DO NOT 13 13 USE USE DO NOT ...

Page 40

... Mode Key Down Key 1.5 58 44.8 44.8 48.8 Waterproof Mounting Adapter Terminal Cover Packing (Accessory) (E53-COV17) (Accessory) (Accessory) Note: The terminal block cannot be removed. LED indicator 250 (SD) USB connector (type A plug) No. 1 display No. 2 display Up Key Panel Cutout Mounted Separately Group Mounted ...

Page 41

... Terminal Cover E53-COV17 Note: The E53-COV10 can not be used. 48 48.8 22 9.1 Current Transformers E54-CT1 E54-CT3 E54-CT3 Accessory Armature Connection Example Plug Approx. 3 dia. 18 Plug Approx. 6 dia. (22) Waterproof Packing Y92S-29 (for DIN 48 48) Order the Waterproof Packing separately if it becomes lost or damaged. ...

Page 42

E5CN-H Adapter Y92F-45 Note: Use this Adapter when the panel has already been prepared for the E5B@. Mounted to E5CN-H 42 4.7 76 69 Panel ( mm 2.2 4.7 77.3 ...

Page 43

Advanced Digital Temperature Controller E5AN-H/E5EN-H A New High-performance Controller: High Resolution, High Speed, and High Input Accuracy. Logic Operations and Preventive Maintenance Function. Plus Infrared Port on Front Panel. High-resolution display with 5 digits/0.01×C display. High-speed sampling cycle of 60 ...

Page 44

... Function EN01: RS-232C communications EN02: RS-422 communications EN03: RS-485 communications AKB: Event input Output Units E53-@@ Control Output R: Relay output Q: Voltage output (for driving SSR) Q3: Voltage output (for driving SSR VDC (NPN) Q4: Voltage output (for driving SSR VDC (PNP) C3: Current output + ...

Page 45

Ordering Information E5AN-H Power Case Control Auxiliary Size supply color method output voltage 2 Basic 100 to 240 VAC 3 Valve 2 Black 1/4 DIN Basic 24 VAC/ VDC 3 Valve 2 100 ...

Page 46

... DC, load: 600 E53-C3N resolution: approx. 10,000 Current output 0 to 20-mA DC, load: 600 E53-C3DN resolution: approx. 10,000 VDC, load E53-V34N Linear approx. 10,000 voltage VDC, load min., resolution: output E53-V35N approx. 10,000 USB-infrared Conversion Cable Model ...

Page 47

... Relay output: SPST-NO, 250 VAC (resistive load), electrical life: 100,000 operations, minimum applicable load: output Output specifications Number of outputs (with an E53-AKB) Contact input: ON max., OFF: 100 k min. Event External contact input input Non-contact input: ON: Residual voltage: 1.5 V max., OFF: Leakage current: 0.1 mA max. ...

Page 48

E5AN-H/E5EN-H Input Ranges Thermocouple/Platinum Resistance Thermometer (Fully Universal Inputs) Input Platinum resistance type thermometer Name Pt100 JPt100 2300 1800 1700 1600 1500 1400 1300.0 1300 1200 1100 1000 850.0 900 800 700 600 500.0 500.0 500 400 300 200.00 200 ...

Page 49

Alarm Outputs Each alarm can be independently set to one of the following 15 alarm types. The default is 2: Upper limit. Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be ...

Page 50

E5AN-H/E5EN-H Characteristics Thermocouple: ( 0.1% of indicated value whichever is greater) 1 digit max. ✽1 Platinum resistance thermometer: ( 0.1% of indicated value or 0.5 C, whichever is greater) 1 digit max. Indication accuracy Analog input: 0.1% ...

Page 51

USB-Serial Conversion Cable Applicable OS Windows 2000, XP, or Vista Thermo Mini, CX-Thermo version Applicable software 4.0 or higher E5AN/E5EN/E5CN/E5CN-U/ Applicable models E5AN-H/E5EN-H/E5CN-H USB interface standard Conforms to USB Specification 1.1. DTE speed 38400 bps Computer: USB (type A plug) ...

Page 52

E5AN-H/E5EN-H Electrical Life Expectancy Curve for Relays (Reference Values) 500 300 E5AN-H/E5EN-H 100 250 VAC, 30 VDC (resistive load) cos = Switching current (A) 52 SSR Outputs ...

Page 53

... V USE USE NOT USE (Load: 600 max E5AN-H/E5EN-H Communications E53-EN03 E53-AKB RS-485 Event Inputs RDB EV2 12 12 RDA EV1 NOT USE SDB SDA Auxiliary output 3 Relay output SPDT, 250 VAC (resistive load) DO NOT USE A heater burnout alarm, SSR failure, heater overcurrent ...

Page 54

... Mounted Separately 120 min ✽ Group mounting is not possible if an SSR output is used for control output and the E53-C3N or E53-C3DN Output Unit is used. For these combinations, maintain the following mounting space between Controllers. Terminal Cover Mounting Bracket (E53-COV16) (Accessory) (Accessory) Crimp terminal size: M3 ...

Page 55

... Mounted Separately +0 120 min. ✽ Group mounting is not possible if an SSR output is used for control output and the E53-C3N or E53-C3DN Output Unit is used. For these combinations, maintain the following mounting space between Controllers Terminal Cover (E53-COV16) (Accessory) Crimp terminal size: M3.5 120 min ...

Page 56

... E5AN-H/E5EN-H Accessories (Order Separately) USB-Infrared Conversion Cable E58-CIFIR USB-Infrared Conversion Cable USB connector (type A plug) Mounting Adapter USB-Serial Conversion Cable E58-CIFQ1 Terminal Covers E53-COV16 (Six Covers provided.) 56 (2,000) With Mounting Adapter Connected 39 16 18.5 Mounting Adapter (Accessory) 99.2 23.1 21.8 (75) ...

Page 57

... IP66. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Waterproof Packing does not need to be attached if a waterproof structure is not required ...

Page 58

E5@N/E5@N-H Operation Setting Levels Diagram This diagram shows all of the setting levels. To move to the advanced function setting level and calibration level, you must enter passwords. Some parameters are not displayed depending on the protect level setting and ...

Page 59

Advanced Type Start in manual mode. Start in automatic mode. Press the O Key or the PF Key for at least 1 s. ✽4 a-m Press the O Key for at least 3 s while a-m is displayed. (a-m will ...

Page 60

E5@N/E5@N-H Parameters Basic Type Some parameters are not displayed depending on the model of the Controller and parameter settings. For details, refer to the E5CN/E5AN/E5EN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156). Press the PF Key for ...

Page 61

Monitor/Setting Item Level 25 C Monitor/Setting PF Item Display 1 0 Note: The monitor/setting items to be displayed is set in the Monitor/Setting Item parameters (advanced function setting level). Press the O Key for at least 1 ...

Page 62

E5@N/E5@N-H Advanced Type Some parameters are not displayed depending on the model of the Controller and parameter settings. For details, refer to the E5CN-H/E5AN-H/ E5EN-H Digital Controllers User's Manual Advanced Type (Cat. No. H157). Protect Level PID Setting Level Display ...

Page 63

Press the PF Key for at least 1 s. ✽1 Press the O Key less than 1 s. Adjustment Level Adjustment Level Display l.adj Displayed only p c once when Proportional Band 8.0 entering adjustment level ...

Page 64

E5@N/E5@N-H Press the O Key for at least 1 s. Press the O Key for at least 3 s. Other than the Auto/Manual Switch display Protect Level The time taken to move to the protect level can be adjusted by ...

Page 65

Power ON Manual Control Level Operation Adjustment Protect Level Level Level Communica- Initial Setting tions Setting Level Level Advanced Function Setting Level Press the O Key for at least 1 s. Advanced Function Setting Level init o-dp MV Display Parameter ...

Page 66

E5@N/E5@N-H Safety Precautions !CAUTION Do not touch the terminals while power is being supplied. Doing so may occasionally result in minor injury due to electric shock. Do not allow pieces of metal, wire clippings, or fine metallic shavings or filings ...

Page 67

ON power to the load (e.g., heater) at the same time as or before supplying power to the product. If power is turned ON to the product before turning ON power to the load, self-tuning will ...

Page 68

... Mounting the Terminal Cover E5CN Make sure that the “UP” mark is facing up, and then attach the E53- COV17 Terminal Cover to the holes on the top and bottom of the Temperature Controller. E5AN/E5EN Slightly bend the E53-COV16 Terminal Cover to attach it to the terminal block as shown in the following diagram ...

Page 69

E5AN/E5EN Tool insertion hole (1) (2) (3) E5AN (1) 1. Insert a flat-blade screwdriver into the two tool insertion holes (one on the top and one on the bottom) to release the hooks. 2. Insert the flat-blade screwdriver in the ...

Page 70

CX-Thermo Support Software Ver. 4.0 EST2-2C-MV4 Monitoring/Setting Support Software for E5CN/CN-H, E5AN/AN-H, E5EN/EN-H, E5ZN, E5@R/@R-T, and EJ1 Temperature Controllers Enabling Faster Parameter Setup, Device Adjustment, and Maintenance Enables editing and batch-downloading parameters from a personal computer, reducing the work required ...

Page 71

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 72

... OMRON ELECTRONICS LLC • THE AMERICAS HEADQUARTERS Schaumburg, IL USA • 847.843.7900 • 800.556.6766 • www.omron247.com OMRON CANADA, INC. • HEAD OFFICE Toronto, ON, Canada • 416.286.6465 • 866.986.6766 • www.omron.ca OMRON ELETRÔNICA DO BRASIL LTDA • HEAD OFFICE São Paulo, SP, Brasil • 55.11.2101.6300 • www.omron.com.br OMRON ELECTRONICS MEXICO • ...

Related keywords