Temperature Controller

E5ENQ3MT500AC100240

Manufacturer Part Number
E5ENQ3MT500AC100240
Description
Temperature Controller
Manufacturer
Omron
Datasheet

Specifications of E5ENQ3MT500AC100240

Operating Temperature Max
55°C
Operating Temperature Min
-10°C
Temperature Accuracy ±
0.3%
Output Voltage Max
13.8VDC
Output Voltage Min
10.2VDC
Supply Voltage Ac, Min
100V
Signal Input Type
Thermocouple
Thermocouple Type
J, K, T, E, L, U, N, R, S, B, W, PLII
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
New 96 x 96-mm and 48 x 96-mm Basic Temperature Controllers with
Enhanced Functions and Performance.
Improved Indication Accuracy and
Preventive Maintenance Function.
Main I/O Functions
• Indication Accuracy
• A PV/SV-status display function can be set to automatically
• Preventive maintenance for relays in the Temperature Controller
• Three-level display that simultaneously displays the PV, SV, and
• One-touch operation with PF Key that can be assigned to auto/
Basic-type Digital Temperature Controller
E5AN/E5EN
Thermocouple input: ±0.3% of PV (previous models: ±0.5%)
Pt input: ±0.2% of PV (previous models: ±0.5%)
Analog input: ±0.2% FS (previous models: ±0.5%)
alternate between displaying the status of the Temperature
Controller (auto/manual, RUN/STOP, and alarms) and the PV or
SV.
using a Control Output ON/OFF Counter.
MV.
manual, RUN/STOP, or other functions.
This data sheet is provided as a guideline for selecting products. Be sure to refer to the following user manuals for application precautions
and other information required for operation before attempting to use the product.
E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers User's Manual Basic Type (Cat. No. H156)
E5CN/E5AN/E5EN/E5GN Digital Temperature Controllers Communications Manual Basic Type (Cat. No. H158)
Sensor Inputs
• Universal thermocouple/Pt inputs
• Analog current/voltage inputs
Indication Accuracy
• Thermocouple input: ±0.3% of PV
• Pt input: ±0.2% of PV
• Analog input: ±0.2% FS
Sampling Period
• 250 ms
(Models with temperature inputs)
(Models with analog inputs)
PF Key
(Programmable function key)
Event Inputs
• None
• Two
Control Output 1
• Relay output
• Voltage output (for driving SSR)
• Current output
E5AN
Control Output 2
• Voltage output
• Long-life relay
output (hybrid)
(for driving SSR)
(96 x 96 mm and 48 x 96 mm)
E5EN
Auxiliary Outputs
• Three
Refer to Operation for E5
procedures.
Refer to Safety Precautions for E5
96 × 96 mm
4-digit Display
E5AN
3-level Display *
Simultaneously displays set items,
such as the PV, SV, and MV.
* A 2-level display when shipped from the factory. A
3-level display is activated if parameters are
initialized. For details on the third display level, refer
to the User’s Manual, Basic Type (Cat. No. H156).
• Auto/manual switching
• Temperature Controller
• Simple program function
• Control output ON/OFF
• PV change rate alarm
• Models also available with
status display
count alarm
RS-485 or RS-232C
communications
@
CSM_E5AN_E5EN_DS_E_4_1
N/E5
@
N-H for operating
48 × 96 mm
@
N/E5
E5EN
@
N-H.
1

Related parts for E5ENQ3MT500AC100240

E5ENQ3MT500AC100240 Summary of contents

Page 1

Basic-type Digital Temperature Controller E5AN/E5EN New 96 x 96-mm and 48 x 96-mm Basic Temperature Controllers with Enhanced Functions and Performance. Improved Indication Accuracy and Preventive Maintenance Function. • Indication Accuracy Thermocouple input: ±0. (previous models: ±0.5%) Pt ...

Page 2

... Terminal Cover -500: With terminal cover 9. Version N: Available only to models released after January 2008. Note: Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for details. Temperature input Analog input Option Units ...

Page 3

Ordering Information E5AN Controllers with Terminal Blocks Power Case Size supply Input type color voltage Thermocouple or Resistance thermometer 100 to 240 VAC Black 1/4 DIN 96 × 96 × 78 Analog (W × H × D) (current/voltage) Thermocouple 24 ...

Page 4

E5EN Controllers with Terminal Blocks Power Case Size supply Input type color voltage Thermocouple or Resistance thermometer 100 to 240 VAC Black 1/8 DIN 48 × 96 × × H × D) Analog (current/voltage) Thermocouple 24 VAC/ or ...

Page 5

Option Units Name Communications Unit Event Input Unit Accessories (Order Separately) USB-Serial Conversion Cable Model E58-CIFQ1 Terminal Cover Connectable models E5AN E53-COV16 E5EN Note: The Terminal Cover comes with the E5CN-@@@-500 models. Waterproof Packing Connectable models E5AN E5EN Note: The ...

Page 6

Specifications Ratings model number: 100 to 240 VAC, 50/60 Hz Power supply voltage D in model number: 24 VAC, 50/60 Hz; 24 VDC Operating voltage range 85% to 110% of rated supply voltage Power 100 to 240 ...

Page 7

Input Ranges Thermocouple/Platinum Resistance Thermometer (Universal inputs) Input Platinum resistance type thermometer Name Pt100 JPt100 K 2300 1800 1700 1600 1500 1400 1300 1300 1200 1100 1000 850 900 800 700 600 500.0 500.0 500.0 500 400 300 200 100.0 ...

Page 8

Alarm Outputs Each alarm can be independently set to one of the following 13 alarm types. The default is 2: Upper limit. Auxiliary outputs are allocated for alarms. ON delays and OFF delays (0 to 999 s) can also be ...

Page 9

Characteristics Thermocouple: (±0.3% of indicated value or ±1°C, whichever is greater) ±1 digit max. *1 Platinum resistance thermometer: (±0.2% of indicated value or ±0.8°C, whichever is greater) ±1 digit max. Indication accuracy Analog input: ±0.2% FS ±1 digit max. CT ...

Page 10

USB-Serial Conversion Cable Applicable OS Windows 2000, XP, or Vista Applicable software CX-Thermo version 4 or higher E5AN/E5EN/E5CN/E5CN-U/E5AN- Applicable models H/E5EN-H/E5CN-H/E5GN USB interface standard Conforms to USB Specification 1.1. DTE speed 38400 bps Computer: USB (type A plug) Connector specifications ...

Page 11

... The voltage output (control output 2, for driving SSR) has basic insulation provided for the internal circuit. • Consult with your OMRON representative before using the external power supply for the ES1B for any other purpose. Controllers The E5@N-@@@T@ is set for a K-type thermocouple • ...

Page 12

Nomenclature E5AN Temperature unit SUB1 SUB2 SUB3 Operation indicators HA OUT1 STOP OUT2 CMW MANU Programmable PF Function Key/ A/M Auto/Manual Key E5AN Level Key Mode Key * A 2-level display when shipped from the factory. A 3-level display is ...

Page 13

E5EN 48 96 Accessories (Order Separately) USB-Serial Conversion Cable E58-CIFQ1 USB connector (type A plug) Terminal Covers E53-COV16 (Six Covers provided.) 6 79.2 2 112 91 Terminal Cover (E53-COV16) Waterproof Mounting Bracket (Accessory) Packing (Accessory) (Accessory) Crimp terminal size: M3.5 ...

Page 14

... IP66. The time for periodic replacement depends on the operating environment. Be sure to confirm this point at your site. Consider one year a rough standard. OMRON shall not be liable for the level of water resistance if the customer does not perform periodic replacement.) The Waterproof Packing does not need to be attached if a waterproof structure is not required ...

Page 15

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...