E5GN-Q1TC AC/DC24 Omron, E5GN-Q1TC AC/DC24 Datasheet - Page 14

Temperature Meter

E5GN-Q1TC AC/DC24

Manufacturer Part Number
E5GN-Q1TC AC/DC24
Description
Temperature Meter
Manufacturer
Omron
Datasheet

Specifications of E5GN-Q1TC AC/DC24

Operating Temperature Max
+55°C
Operating Temperature Min
-10°C
Temperature Accuracy ±
0.5%
Output Voltage Max
12VDC
Controller Input
Thermocouple
Controller Output Type 1
Voltage/SSR
Mounting Type
Panel
Thermocouple Type
J, K, T, E, L, U, N, R, S, B, W, PLII
Meter Function
Temperature
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
External Connections
E5GN
Wiring
E5GN
Models with Screw Terminal Blocks (M3 Screws)
Relay output
Voltage output (for driving SSR)
Current output
• A voltage output (control output, for driving SSR) is not electrically
Relay outputs
250 VAC, 2 A (resistive load)
12 VDC, 21 mA
0 to 20 mA DC
4 to 20 mA DC
Load: 500 Ω max.
250 VAC, 2 A (resistive load)
insulated from the internal circuits. When using a grounding
thermocouple, do not connect any of the control output terminals to
Auxiliary outputs 1 and 2
Control output 1
Auxiliary output 2
connection screws
13
Auxiliary
output 2
14
• 100 to 240 VAC
• 24 VAC/VDC (no polarity)
M3 Screw Terminal Blocks
The E5@N-@@@T@ is set for a K thermocouple
(input type of 5) by default. If a difference sensor is
used, an input error (s.err) will occur. Check the
setting of the input type parameter.
RS-232C
communications
RS-485
communications
Crimp terminal shape: Forked or round
Tightening torque for all terminals: 0.5 N
Event input
CT input
B (+)
5.8 mm max.
5.8 mm max.
Input power
SD
7
1
supply
CT
A (−)
RD
8
2
EV1
m
DO NOT
USE
+ Control
DO NOT
USE
SG
EV2
9
3
output 1
DO NOT
USE
+
10
4
Controllers
E5GN-@-C
Models with Screwless Clamp Terminal Blocks
A
mA
ground. (If the control output terminals are connected to ground,
errors will occur in the measured temperature values as a result of
leakage current.)
11
5
Models with Screw
Terminal Blocks
Auxiliary
output 1
Terminal Arrangement
B
1
7
V
DO NOT
USE
2
8
12
6
B
+
+
9 10 11 12
3
Universal TC/Pt input
Analog input
4
5
6
A heater burnout alarm, heater short
alarm, heater overcurrent alarm, or
input error is sent to the output to
which the alarm 1 function is assigned.
Models with Screwless Clamp Terminal Blocks
Wire stripping: 10 mm
Ferrules: 8 to 12 mm
Models with Screwless
Clamp Terminal Blocks
10 mm
7
1
8
2
9 10 11 12
3
0.8 to 1.4 mm
4
5
E5GN
8 to 12 mm
6
14

Related parts for E5GN-Q1TC AC/DC24