E-TRANSFORMER-127 CAL CONTROLS, E-TRANSFORMER-127 Datasheet

TRANSFORMER, 240VAC TO 12VAC

E-TRANSFORMER-127

Manufacturer Part Number
E-TRANSFORMER-127
Description
TRANSFORMER, 240VAC TO 12VAC
Manufacturer
CAL CONTROLS
Datasheet

Specifications of E-TRANSFORMER-127

Operating Temperature Max
50°C
Operating Temperature Min
0°C
Approval Bodies
CE
Supply Voltage Max
240VAC
Supply Voltage Min
12VAC
For Use With
NTC Thermostats
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Order Code : EDT1411-NTC-
Connection Diagram
* 34 x 77mm sized.
* On-Off control.
* Single contact output for cooling control.
*
* Offset value can be entered for
* Compressor protection parameters can be entered.
* In the case of probe failure, output state can be
* Upper and lower limits of the setpoint can be adjusted.
* Defrosting duration and interval can be adjusted.
* 16 different warning tones.
* Upper and lower limits of the alarm value can be adjusted depending on the setpoint value.
* CE marked according to European Norms.
1 - Supply Voltage
CAL EDT1411 THERMOSTAT
selected on or off or periodical running.
NTC
Thank you for choosing the CAL EDT1411 thermostat.
SN: XXXXXXXXX
SUPPLY:
184-253V AC
50/60Hz 3VA
1
NOTE:
230VAC...230V AC
24............24V AC/DC
12............12V AC/DC
EDT1411-NTC-230VAC
DIGITAL DEFROST THERMOSTAT
2
probe input for cold room temperature.
3
4
www.cal-controls.com
CAL EDT1411 is intended for installation in control panels. Make sure that the device is used
only for intended purpose. The electrical connections must be carried out by qualified staff
and must be according to the relevant locally applicable regulations. During an installation, all of the
cables that are connected to the device must be free of electrical power. The device must be
protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation
temperature is not exceeded. The cables should not be close to the power cables or components.
5
7
8
6
7
Neutral
Line
8
9 10 11 12
Holding screw
0.4-0.5Nm.
W
Fuse should
be connected
F 100 mA
SENSOR
250V AC
NTC
Fuse
R
NTC
SN: XXXXXXXXX
1
1
2 - Output
EDT1411-NTC-24
DIGITAL DEFROST THERMOSTAT
Switch
Cable size: 1,5mm²
2
probe.
P..........Relay-16A
None...Relay-8A
3
-
2
4
www.cal-controls.com
5
230V AC
Supply
6
Equipment is protected throughout
by DOUBLE INSULATION
7
8
Note:
1) Mains supply cords shall meet the requirements of
2) In accordance with the safety regulations, the power
9 10 11 12
IEC 60227 or IEC 60245.
supply switch shall bring the identification of the
relevant instrument and it should be easily
accessible by the operator.
W
SENSOR
CAL
NTC
°F
R
SN: XXXXXXXXX
1
EDT1411-NTC-230VAC-P
DIGITAL DEFROST THERMOSTAT
2
3
4
www.cal-controls.com
5
6
°C
7
SET
8
EDT1411
9 10 11 12
W
SENSOR
NTC
R
1/3
Technical Specifications
CAL CONTROLS LTD
Bury Mead Road, Hitchin, Herts, SG5 1RT, UK.
Tel : +44 (0) 1462 436161
e-mail: sales@cal-controls.co.uk
Dimensions
ENVIRONMENTAL CONDITIONS
Ambient/storage temperature
Rated pollution degree
Supply voltage
EMC
Safety requirements
HOUSING
Housing type
Dimensions
Enclosure material
Max. relative humidity
Height
ELECTRICAL CHARACTERISTICS
Power consumption
Wiring
Scale
Sensitivity /Accuracy
Time Accuracy
Indicator
OUTPUT
COMPRESSOR
Life expectancy for relay
CONTROL
Control type
Control algorithm
Hysteresis
Weight
CAL
Do not use the device in locations subject to corrosive and flammable gasses.
While cleaning the device, solvents (thinner, benzine, acid etc.) or
°F
W
SENSOR
12
NTC
11
R
THERMOSTAT
10
www.cal-controls.com
9
8
85mm
7
EDT1411-NTC-230VAC
6
DEFROST
Fax : +44 (0) 1462 451801
5
XXXXXXXXX
°C
For
On-Off control
Adjustable between 0.1 ... 20.0°C.
Approx. 250g (
Self extinguishing plastics
4
230V AC +%10 -%20, 50/60Hz or 24V AC/DC ±%10, 50/60Hz or 12V AC/DC ±%10, 50/60Hz.
Max. 3VA
2.5mm² screw-terminal connections.
-50.0 ... +110.0°C (-58.0 ... +230.0°F)
0.1°C /
( %1-15sec) for hour unit, ( %1-1sec) for minute unit
4 digits, 12mm, 7 parts yellow LED
EN 61326-1: 1997, A1: 1998, A2: 2001 (Performance criterion B is satisfied for EMC tests.
The device is designed to operate in controlled electromagnetic environment)
EN 61010-1: 2001 (Pollution degree 2, overvoltage category II)
For
For
For
Single-setpoint control
Suitable for panel mounting.
W77xH34xD70mm
±
SET
3
DIGITAL
80 , up to
According to EN 60529
Max. 2000m
EDT1411-NTC-XXP;
0 ... +50°C/-25 ... 70°C (with no icing)
EDT1411-NTC-XX ;
EDT1411
EDT1411-NTC-XX ;
EDT1411-NTC-XXP;
2
Web : www.cal-controls.com
SN:
%
1
±1
°C
after packing the device and a probe
31°C decreasing linearly 50% at
mounting
1
For removing mounting clamps:
clamp
Push out the mounting clamp
in direction
in the figure below. Then, pull
out the clamp in direction
Relay: 250V AC, 8A (
Relay: 240V AC, 16A (
1
1/2 HP 240V AC
Mechanical 30.000.000; Electrical 100.000operation.
Mechanical 30.000.000; Electrical 30.000operation.
HP 230V AC
±
Panel cut-out
Front panel : IP60
Rear panel : IP20
1
as shown
Cos = 0.5
71mm
Cos = 0.4
F
for resistive load
F
for resistive load
corrosive materials
40
2.
°C
mounting
(for inductive load)
)
clamp
(
for inductive load
Note : 1) Panel thickness
), NO+NC;
), NO;
2) If there is no 60mm
must not be used.
Depth
should be maximum
7 mm.
free space at the back
side of the device, it
would be difficult to
remove it from the
p
70mm
anel
)
2
Panel
EDT1411-E-06
Rubber
gasket
8mm

Related parts for E-TRANSFORMER-127

E-TRANSFORMER-127 Summary of contents

Page 1

... The electrical connections must be carried out by qualified staff and must be according to the relevant locally applicable regulations. During an installation, all of the cables that are connected to the device must be free of electrical power. The device must be protected against inadmissible humidity, vibrations, severe soiling and make sure that the operation temperature is not exceeded ...

Page 2

... When held down for 3 second in the run mode, manual defrost starts. After the specified time with °F specified time ends. Used for selecting menu and increasing setpoint value of the parameters in the programming mode and for increasing the setpoint value in the run mode When held down for a few °C seconds, the change rate accelerates ...

Page 3

... D.drE Delay time for display real temperature after defrost is over. D.Pon y Defrosting after power is on.( =Defrosting begins when power is on, =Defrosting doesn’t begin when power is on.) D.dPo Delay time for defrosting after power is on. Al Menu of Alarm control parameters A ...

Related keywords