TEMPERATURE CONTROLLER, K, T/C

TC4810-01

Manufacturer Part Number
TC4810-01
Description
TEMPERATURE CONTROLLER, K, T/C
Manufacturer
TEMPATRON
Datasheet

Specifications of TC4810-01

Thermocouple Type
K
Operating Temperature Max
50°C
Operating Temperature Min
-10°C
Output Voltage Max
240VAC
Accuracy
± 2%
Approval Bodies
CE, EN50081-1, EN50082-1, EN61010-1
SPECIFICATION
Supply voltage:
Power drain:
Scale accuracy:
Sensing ranges:
Input sensor:
Output rating:
Electrical life:
Metering output:
Ambient range:
Approvals:
STANDARD ITEMS
DIMENSIONS
CONNECTION DIAGRAM
Note: For suitable panel mounting or DIN rail wiring sockets see page 33.
Part Numbering Options : TR4801 - A - B
Type
Tachometer relay
Tachometer relay
Tachometer relay
A
B
3 models for 5 to 10,000 rpm
1mA meter output to display rpm
TR4800 TACHOMETER RELAY
15
Panel Cut-out 45 x 45 mm
Range
Power
supply
230V/24V
110V
110/230(220-240)Vac @ 50/60 Hz or 24Vac/dc
3VA or 2 Watts max.
+/- 2% of full scale
01:
02:
03:
Any volt-free contact or 3-wire active sensor with a
power consumption of < 25mA at 15Vdc. See SI and
SC range of sensors on pages 29 and 30.
SPCO relay rated at 5A/240Vac/30Vdc resistive
100,000 ops at rated load
1 mAmp fsd at 75
-10 to 60 C non-condensing
Conforms to CE emc EN50081-1 & EN50082-1 and
low voltage EN61010-1 directives
500 - 10000 rpm
110/230Vac
24Vac/dc
74
50 - 1000 rpm
5 - 100 rpm
500 -10000 rpm
50 -1000 rpm
4
3
5 -100 rpm
Range
-
5
+15V
2
o
5 to 100 rpm
50 to 1000 rpm
500 to 10000 rpm
6
The TR4800 series tachometer relay will
switch it's output at the speed selected on
the front dial. The units are designed to
match the styling of the TC4800 temp-
erature controllers and TT4800 Timers.
They offer a fast reaction time of <0.4sec
at 150rpm, have an internal supply to
power active sensors and a meter output
to display the measured speed. The
range consists of three models covering
speeds from 5 to 10,000 rpm.
1
7
-0
+0.5
11
ANALOGUE PROCESS CONTROLLERS
8
10
17
9
N
High speed response to input
Internal 15Vdc sensor supply
01
02
03
110/230VAC
24VAC/DC
+
-
TR4801-01-110/230VAC
TR4801-02-110/230VAC
TR4801-03-110/230VAC
Part Number
Sensor
NPN
48 sq
14
SPECIFICATION
gise and this signal can be used to disable a guard. By using the normally
closed contacts the sensor becomes fail-safe in the event of loss of power
DIMENSIONS
CONNECTION DIAGRAM
Supply voltage : 110/230(220-240)Vac @ 50/60 Hz
Power drain :
Time delay :
Sensing speed : Calculated by S = 60/nT rpm
Min. Pulse width: 3 msecs (for 50% duty cycle). To calculate the minimum
Input sensor:
Output rating:
Electrical life:
Ambient range:
Approvals:
STANDARD ITEM
Note: For suitable panel mounting or DIN rail wiring sockets see page 33.
Type
Shaft Rotation Sensor
FLST LIQUID LEVEL DETECTOR
Differential or single point sensing
Dual supply voltage
FSRS SHAFT ROTATION SENSOR
8
10
6
4
12
2
1
14
16 18
230V/24Vac
110Vac
30
20
28
22
26
24
4VA
1 to 30 seconds
where n = No. of pulses per revolution
'flag' width (W ) use the formula W = r/10 mm
(50% duty) where r = radius of shaft
Any volt-free contact (no bounce) or 3-wire active
Sensor with a power consumption of < 25mA at 24Vdc.
See SI or SC series sensors on pages 29 - 30.
SPCO relay rated at 5A/240Vac/30Vdc resistive
100,000 ops at rated load
10 to 50 C non-condensing
Conform to CE emc EN50081-1 & EN50082-1 and
low voltage EN61010-1 directives
T = time set on potentiometer
o
4
3
Delay
30 sec
-
5
+24V
2
f
The FLST liquid level detector has a
fixed sensitivity, designed primarily to
sense water using a conductive differ-
ential sensing device. By shorting the
high and low probes, however, it can
also be used for single point detection.
Under differential operation, the output
relay will energise when the liquid falls
below the 'Low' level and de-energise
when it rises above the 'High' level.
The FSRS shaft rotation sensor is
specifically designed to prevent access
to a
has slowed to a safe speed. An
adjustable potentiometer on the facia
enables the sensor to be set for an
appropriate minimum speed which may
be considered as safe for the operator
to gain access. If the sensor does not
receive a pulse within the time set by
the potentiometer, it's output will ener-
min
6
19
1
normally rotating
7
11
N
Panel Cut-out 45 x 45 mm
8
10
9
Level indicating LEDs
FSRST30SLP-110/230VAC
+
-
Part Number
99
f
machine until it
Sensor
NPN
-0
+0.5
13

Related parts for TC4810-01