D5A-1100 Omron, D5A-1100 Datasheet - Page 9

LIMIT SWITCH, PLUNGER, SPST-NC

D5A-1100

Manufacturer Part Number
D5A-1100
Description
LIMIT SWITCH, PLUNGER, SPST-NC
Manufacturer
Omron
Datasheets

Specifications of D5A-1100

Actuator Style
Plunger
Operating Force Max
0.29N
Contact Voltage Ac Max
24V
Contact Voltage Dc Max
12V
Contact Current Ac Max
10mA
Contact Current Dc Max
10mA
Switch Terminals
Cable
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
D5A
J SERIES CONNECTION OF SWITCHES
The Solid-state Output-type Switches must not be connected in
series. To obtain the same effect as a series connection, form an
AND gate with a relay inserted between the Switch and load.
J PARALLEL CONNECTION OF SWITCHES
In principle, two or more D5A’s should not be used in an OR
configuration.
However, they can be connected in parallel provided that both
switches A and B in the above figure do not operate at the same
time and that the load does not have to be kept energized. In this
circuit, however, the leakage current is increased, multiplied by
the number of Switches connected in parallel. Consequently, the
Switch may not release properly. To keep the load energized,
connect a relay to each of the Switches as shown below.
Cat. No. GC MSEN4
1-800-55-OMRON
OMRON ELECTRONICS LLC
One East Commerce Drive
Schaumburg, IL 60173
D5A
D5A
D5A
D5A
A
D5A
Brown
Blue
Brown
Blue
Brown
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
Blue
X
1
Brown
Blue
Brown
Blue
X
D5A
1
D5A
D5A
Brown
B
Blue
Brown
Brown
Blue
Blue
Load
X
2
X
2
Load
X
Load
1
Load
R
4/01
X
X
X
2
1
2
OMRON ON- -LINE
Global -- http://www.omron.com
USA -- http://www.omron.com/oei
Canada -- http://www.omron.com/oci
Specifications subject to change without notice.
J CONNECTION TO POWER SOURCE
Be sure to connect the Switch to the power source via the load. If
directly connected to the power source, the internal elements of
the Switch may be damaged.
Correctly connect the white and black lead wires to the positive
and negative sides, respectively, of the power source. Although
the D5A will not be damaged even if the polarity is reversed by
mistake, if this happens, the Switch maintains the ON state (i.e.,
the contact is kept open) regardless of the presence or absence
of the object to be detected.
D5A
D5A
Brown
Brown
Blue
Blue
Always close
circuit
Load
OMRON CANADA, INC.
416-286-6465
885 Milner Avenue
Scarborough, Ontario M1B 5V8
Printed in U.S.A.
D5A

Related parts for D5A-1100