XCKM106H7 SQUARE D, XCKM106H7 Datasheet - Page 123

LIMIT SWITCH, 1NO/1NC, 240VAC, 250VDC, 10A

XCKM106H7

Manufacturer Part Number
XCKM106H7
Description
LIMIT SWITCH, 1NO/1NC, 240VAC, 250VDC, 10A
Manufacturer
SQUARE D
Datasheet

Specifications of XCKM106H7

Actuator Style
Wobble Rod
Operating Force Max
0.13N
Switch Operation
(ON)
Contact Voltage Ac Max
240V
Contact Voltage Dc Max
250V
Contact Current Ac Max
10A
Contact Current Dc Max
10A
Rohs Compliant
Yes
Limit Switches
Osiswitch
XCKJ—Modular, Fixed Non-plug-in or Plug-in Bodies—Components
03/2007
Function diagrams
Head ZCKE05 with body
ZCKJ1•
ZCKJD39
ZCKJ4•
Unactuated
Head ZCKE09 with body
ZCKJ1•
21-22
13-14
21-22
13-14
ZCKJ404, J4104 (body with head)
Unactuated
Contact operation
Indicator light modules
1 LED, 24 Vc
1.
2.
ZCKJ•D
1–2= N/C
3–4= N/O
5= t
4 A / 24 V max.
21-22
31-32
13-14
21-22
31-32
13-14
3
Wiring diagrams
21-22
13-14
21-22
13-14
0
0
Orange indicator
Green indicator
0
2
4
1
0
(1)
®
+
Classic, Metal, Conforming to CENELEC EN 50041
ZCKJ2•
ZCKJD37
21-22
31-32
13-14
ZCKJ2•
11-12/21-22
13-14/23-24
11-12/21-22
13-14/23-24
11-12/21-22
13-14/23-24
11-12/21-22
13-14/23-24
0
2 LEDs, 24 Vc
(positive operation assured only if the associated sub-assemblies are
0
0
0
(1)
ZCKJ5•
ZCKJD39
ZCKJD31
G contact closed
H contact open
21-22
33-34
13-14
21-22
33-34
13-14
21-22
33-34
13-14
21-22
13-14
0
0
0
(2)
+
ZCKJ6
ZCKJD31
21-22
33-34
13-14
21-22
33-34
13-14
1
ZCKJD39
Actuated from left
(P) = positive opening point
2 neon lights, 110/120 or 220/240 Va
21-22
31-32
13-14
21-22
31-32
13-14
st
21-22
13-14
0
0
step, actuated from left or right
(1)
ZCKJ7
11-12
21-22
(2)
© 1997–2007 Schneider Electric All Rights Reserved
ZCKJ8
2
Actuated from right
Module with resistor
nd
)
13-14
23-24
step, actuated from left or right
15 k
1/4 W
ZCKJ9
11-12
21-22
11-12
21-22
0
123