WLCLG Omron, WLCLG Datasheet - Page 10

no-image

WLCLG

Manufacturer Part Number
WLCLG
Description
LIMIT SWITCH, ROD
Manufacturer
Omron
Datasheet

Specifications of WLCLG

Operating Force Max
1.39N
Contact Voltage Ac Max
500V
Contact Voltage Dc Max
250V
Contact Current Ac Max
10A
Contact Current Dc Max
10A
Switch Terminals
Screw
Svhc
No SVHC (15-Dec-2010)
Actuator Type
Rod
WL
Note: 1. The above figures are initial values.
Engineering Data
10
Electrical Life Expectancy
Operating temperature: 5°C to 30°C
Operating humidity: 40% to 70%.
Degree of protection
Life expectancy (see note 3)
Operating speed
Operating frequency
Rated frequency
Insulation resistance
Contact resistance
Dielectric strength
Rated insulation voltage (U
Switching overvoltage
Pollution degree
(operating environment)
Short-circuit protective device (SCPD)
Conditional short-circuit current
Conventional enclosed thermal current
(I
Protection against electric shock
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Weight
the
Characteristics
)
2. The figures in parentheses for dielectric strength, are those for the overtravel (high-sensitivity) model.
3. Life expectancy values are calculated at an operating temperature of 5°C to 35°C, and an operating humidity of 40% to 70%. Con-
4. 10,000,000 operations min. for general, high-sensitivity, and flexible rod overtravel models.
5. 500,000 operations min. for high-precision and outdoor specifications models. All microload models however, are 1,000,000 opera-
6. Except the flexible rod models.
7. For low temperature models this is --40_C to 40°C (no icing). For heat-resistive models the range is +5°C to 120°C.
tact your OMRON sales representative for more detailed information on other operating environments.
tions min.
480 VAC
250 VAC
Operating frequency: 30 operations/min
cosφ = 1
125 VAC
Switching current (mA)
i
)
IP67
Mechanical: 15,000,000 operations min. (see note 4)
Electrical:
1 mm to 1 m/s (for WLCA2)
Mechanical: 120 operations/minute min.
Electrical:
50/60 Hz
100 MΩ min. (at 500 VDC)
25 mΩ max. (initial value)
1,000 VAC (600 VAC), 50/60 Hz for 1 min between non-continuous terminals.
2,200 VAC, 50/60 Hz for 1 min/Uimp 2.5 kV non-current-carrying metal part and ground.
2,200 VAC, 50/60 Hz for 1 min Uimp 2.5 kV between each terminal and
non-current-carrying metal part.
250 V (EN60947-5-1)
1,000 V max. (EN60947-5-1)
3 (EN60947-5-1)
10 A, fuse type gG or gI (IEC269)
100 A (EN60947-5-1)
10 A, 0.5 A (EN60947-5-1)
Class I
10 to 55 Hz, 1.5-mm double amplitude (see note 6)
Destruction: 1,000 m/s
Malfunction: 300 m/s
Operating:
Operating:
Approx. 275 g (in the case of WLCA2)
750,000 operations min. (see note 5)
30 operations/minute min.
95% max.
--10°C to 80°C (with no icing) (see note 7)
2
min. (see note 6)
2
min.
WL

Related parts for WLCLG