Safety Limit Switch D4N Upgraded Safety Limit Switches Based on the Popular D4D, Providing a Full Lineup Conforming to International Standards • Lineup includes three contact models with 2NC/1NO and 3NC contact forms in addition to the previous contact forms ...
Page 2
Ordering Information ■ List of Models Switches with Two Contacts Actuator Conduit size Roller lever (resin 1-conduit Pg13.5 lever, resin roller) G1/2 1/2-14NPT M20 M12 connector 2-conduit Pg13.5 G1/2 M20 Roller lever (metal 1-conduit Pg13.5 lever, resin roller) G1/2 1/2-14NPT ...
Page 3
Actuator Conduit size One-way roller 1-conduit Pg13.5 arm lever G1/2 (horizontal) 1/2-14NPT M20 M12 connector 2-conduit Pg13.5 G1/2 M20 One-way roller 1-conduit Pg13.5 arm lever G1/2 (vertical) 1/2-14NPT M20 M12 connector 2-conduit Pg13.5 G1/2 M20 Adjustable roller 1-conduit Pg13.5 lever, ...
Page 4
Actuator Conduit size Roller lever (metal 1-conduit Pg13.5 lever, resin roller) G1/2 1/2-14NPT M20 M12 connector 2-conduit Pg13.5 G1/2 M20 Roller lever (metal 1-conduit Pg13.5 lever, metal roller) G1/2 1/2-14NPT M20 M12 connector Roller lever (metal 1-conduit Pg13.5 lever, bearing ...
Page 5
Actuator Conduit size Adjustable roller 1-conduit Pg13.5 lever, form lock G1/2 (metal lever, resin 1/2-14NPT roller) M20 M12 connector 2-conduit G1/2 M20 Adjustable roller 1-conduit Pg13.5 lever, form lock G1/2 (metal lever, 1/2-14NPT rubber roller) M20 M12 connector 2-conduit G1/2 ...
Page 6
... UL (See note 2.) UL508, CSA C22.2 No.14 E76675 CCC (CQC) GB14048.5 Note: 1. Consult your OMRON representative for details. 2. Approval for CSA C22.2 No authorized by the UL mark. 3. Ask your OMRON representative for information on approved models. D4N B-10 Safety Limit Switch Built-in switch mechanism 2NC/1NO ...
Page 7
... Otherwise, premature wear, Switch damage or malfunctioning may occur. 4. The durability is for an ambient temperature and an ambient humidity of 40% to 70%. For more details, consult your OMRON representative the ambient temperature is greater than not pass the 3-A, 250-VAC load through more than 2 circuits. 6. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual load beforehand ...
Page 8
Connections ■ Contact Form Model Contact D4N-@1@ 1NC/1NO (Snap- action) D4N-@2@ 2NC (Snap-action) D4N-@A@ 1NC/1NO (Slow- action) D4N-@B@ 2NC (Slow-action) D4N-@C@ 2NC/1NO (Slow- action) D4N-@D@ 3NC (Slow-action) D4N-@E@ 1NC/1NO MBB (Slow-action) D4N-@F@ 2NC/1NO MBB (Slow-action) Note: 1. Terminals are numbered ...
Page 9
Operation ■ Direct Opening Mechanism 1NC/1NO Contact (Slow-action) Contact spring Return spring 2NC Contact (Slow-action) Contact spring Return spring Nomenclature ■ Structure Safety-oriented Lever Setting (Form-lock construction) Grooves which engage the lever are cut in the lever and rotary shaft ...
Page 10
Dimensions ■ Switches Note: All units are in millimeters unless otherwise indicated. 1-conduit Models Roller Lever (Resin Lever, Resin Roller) D4N-1@20 D4N-2@20 D4N-3@20 D4N-4@20 D4N-9@20 (See note 2.) 17.5 dia. 6.8 resin roller 26R Resin lever 18 9 0.2 2.5 ...
Page 11
Models Plunger D4N-1@31 D4N-2@31 D4N-3@31 D4N-4@31 D4N-9@31 (See note 2.) 25 0.1 Two, 3 0.05 dia. (31.5) holes 21.5 12 dia. 11 6-dia. resin plunger OP 9 0.2 2.5 20 0.1 47 0.2 22 0.1 55 2.15 0.05R mounting ...
Page 12
Snap-action (1NC/1NO) (2NC), Slow-action (2NC) (3NC) Model D4N-@131 D4N-@132 D4N-@162 D4N-@231 D4N-@232 D4N-@262 D4N-@B31 D4N-@B32 D4N-@B62 D4N-@D31 D4N-@D32 D4N-@D62 OF max. 6.5 N 6 min. 1.5 N 1 max ...
Page 13
Models Adjustable Roller Lever, Form Lock (with Metal Lever, Resin Roller) D4N-1@2G D4N-2@2G D4N-3@2G D4N-4@2G D4N-9@2G (See note 2.) 17.5 dia. 6.8 resin roller 20 to 66R 18 9 0.2 2.5 47 0.2 55 2.15 0.05R 20 0.1 mounting ...
Page 14
Models Fork Lever Lock (Right Operation) D4N-1@RE D4N-2@RE D4N-3@RE D4N-4@RE Two, 17.5 dia. 8 rubber rollers 90 26R 18 9 0.2 2 0.2 0.1 55 2.15 0.05R mounting holes 22 0.2 Conduit cap 31 max. ...
Page 15
Models Roller Lever (Resin Lever, Resin Roller) D4N-5@20 17.5 dia. 6.8 D4N-6@20 resin roller D4N-8@20 26R Resin lever 5 2.15 0.05R 0.1 25 dia. 40 0.1 mounting holes Conduit cap 42 (3) ...
Page 16
Models One-way Roller Arm Lever (Horizontal) Operating direction D4N-5@62 14.8 D4N-6@62 12 dia 0.2 resin roller D4N-8@62 13.5 20R OP 23.3 5.4 2.5 19.5 0.2 20 0.1 2.15 0.05R 22 0.1 mounting holes 25 dia. 40 ...
Page 17
Models Fork Lever Lock (Right Operation) D4N-5@RE D4N-6@RE D4N-7@RE D4N-8@RE Two, 17.5 dia. 8 rubber rollers 90 26R 5.4 2 21.5 0.2 20 0.1 2.15 0.05R 39 0.2 22 0.1 mounting holes 25 dia. 40 0.1 47 ...
Page 18
Levers Refer to the following for the angles and positions of the watchdogs (source: EN50047.) Roller Lever Adjustable Roller Lever, Form Lock (D4N-@@20) (with Metal Lever, Resin Roller) (D4N-@@2G) (Reference Values min Dog Dog ...
Page 19
Safety Precautions Refer to the “Precautions for All Switches” on page I-2 and “Precautions for All Safety Limit Switches” on page B-2. !CAUTION Do not use metal connectors or conduits. If the Switch is made of resin, damage at the ...
Page 20
... Tolerance Pin No. (Terminal No.) • Applicable socket: XS2F (OMRON). • Refer to the Connector Catalog for details on socket pin numbers and lead wire colors. Wire size Socket Tightening (Connector Type • Turn the socket connector screws by hand and tighten until no space remains between the socket and the plug. ...
Page 21
Recommended Connectors Use connectors with screws not exceeding 9 mm, otherwise the screws will protrude into the case interior, interfering with other components in the case. The connectors listed in the following table have connectors with thread sections not exceeding ...
Page 22
Dimensions (Unit: mm) Discontinued Models (1-conduit Plunger-type D4D-N) 25 dia. 0.1 Two, 3 0.05 dia. holes 12 dia. 6-dia. resin plunger OP 2.15±0.05R mounting holes 31 max. Discontinued Models (2-conduit Plunger-type D4D-N) Two, 3 0.05 dia. holes depth ...
Page 23
List of Recommended Substitute Products : The actuator on the D4D non-safety type. The D4N is recommended for safety applications (form lock type). Be sure to mount it correctly screws are recommended to comply with European ...
Page 24
General-purpose Limit Switches D4D-N product to be Recommended discontinued substitute product D4D-1121N D4N-112G D4D-2121N D4N-212G D4D-3121N D4N-312G D4D-5121N D4N-512G D4D-6121N D4N-612G D4D-1127N D4N-112H D4D-2127N D4N-212H D4D-3127N D4N-312H D4D-5127N D4N-512H D4D-6127N D4N-612H D4D-1180N D4N-4180 D4D-2180N D4N-2180 D4D-3180N D4N-3180 D4D-5180N D4N-8180 D4D-6180N ...
Page 25
... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...
Page 26
Cat. No. GC SAFETY-3 07/05 Specifications subject to change without notice Printed in USA ...