LIMIT SWITCH, ROLLER LEVER, SPDT

AZH1021

Manufacturer Part Number
AZH1021
Description
LIMIT SWITCH, ROLLER LEVER, SPDT
Manufacturer
PANASONIC EW
Datasheet

Specifications of AZH1021

Actuator Style
Roller Lever
Operating Force Max
2.45N
Contact Voltage Ac Max
250V
Contact Voltage Dc Max
250V
Contact Current Ac Max
5A
Contact Current Dc Max
5A
Switch Terminals
Screw
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
HL (AZH)
MOUNTING METHOD
Side mounting
1. Die casting case
M4 screw is used for mounting on side.
Mount it firmly with washer. Mounting
torque is 1.37 to 1.57 N·m {14 to 16
kg·cm}.
Remove the hexagonal nut when plunger
type is used in side mounting.
APPLICABLE WIRE
(For screw terminal)
Sealed rubber of the lead wire is applica-
ble for 6 dia. to 8 dia.
CONNECTOR TYPE
1) The cord outlet direction is inter-
changeable. Refer to “HOW TO
CHANGE THE CORD OUTLET DIREC-
TION FOR CONNECTOR TYPE”.
2) Do not remove the connector over 50
times.
3) Wiring diagram as shown below.
Note: Contact No. 1 is not in use.
30
Side mounting hole dimensions
wire name
Vinyl cab-
tyre cord
Electric
(VCTF)
Contact No. of connector
2
3
strand
2-wire
3-wire
Wire
1.299 .006
33 0.15
2-4.3 dia. or M4 screw hole
2-.169 dia.
Applicable wire
Conductor
0.75 mm
1.25 mm
0.75 mm
1.25 mm
2.0 mm
Contact No. 2
Contact No. 4
Contact No. 3
2
COM
2
2
2
2
N.O.
N.C.
6.6 mm dia.
7.4 mm dia.
8.0 mm dia.
7.0 mm dia.
7.8 mm dia.
1
4
diameter
Finished
outside
2. Plastic case
M4 screw is used for mounting on side.
Mount it firmly with washer. Mounting
torque is 1.18 to 1.47 N·m {12 to 15
kg·cm}.
WIRING
1) M3 small binding screw is used as a
terminal screw.
2) When wiring, don’t connect the lead
wire to the terminal directly. Fasten the
crimped terminals securely applying a
tightening torque of 0.20 to 0.29 N·m {2
to 3 kg·cm}. Avoid using solder when
wiring.
3) Refer to the following diagram for
power supply wiring.
4) Take note the terminal arrangement is
different between plunger type and lever
type. (The arrangement of N.C. and N.O.
is reversed.)
4) When the angle type of connector
cord is used, the cord outlet direction is
as follows.
Side mounting hole dimensions
Approx. .591
Approx. 15
(For screw terminal)
1.299 .006
33 0.15
Approx. 1.181
2-4.3 dia. or M4 screw hole
2-.169 dia.
Approx. 30
Approx. 45
Approx. 1.772
Cord outlet direction (Right side)
Cord outlet direction (Left side)
(Unit: mm inch)
Panel mounting
(Panel plunger type)
When the panel mounting type is fixed
on the panel, the torque of hexagonal nut
is set under 7.84 N·m {80 kg·cm}.
5) Mount the terminal case securely after
ensuring that the rubber seals are
attached at the proper positions. Do a
visual check to make sure that the retain-
er is properly inserted on the protrusion
of the case. When installing the terminal
case of the plastic case type, push the
terminal case until it clicks into place,
and make sure there is no play after-
wards.
Panel mounting hole dimensions
COM
terminal
COM
terminal
Plunger type
Lever type
N.O.
terminal
N.C.
terminal
N.C.
terminal
N.O.
terminal
14.5 0.2 dia.
.571 .008 dia.