HS6E-L44B03-G IDEC, HS6E-L44B03-G Datasheet

SWITCH, SAFETY INTERLOCK, 2NC, 2A

HS6E-L44B03-G

Manufacturer Part Number
HS6E-L44B03-G
Description
SWITCH, SAFETY INTERLOCK, 2NC, 2A
Manufacturer
IDEC
Series
HS6Er
Datasheet

Specifications of HS6E-L44B03-G

Contact Voltage Ac Max
125V
Contact Voltage Dc Max
30V
Contact Current Ac Max
2A
Contact Current Dc Max
2A
Switch Terminals
Cable
Contact Configuration
SPST-NC / SPST-NC
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
(07/03/12)
Subminiature Interlock Switches with Solenoid
Subminiature Interlock Switches
HS6E
HS6B

Related parts for HS6E-L44B03-G

HS6E-L44B03-G Summary of contents

Page 1

... HS6E Subminiature Interlock Switches with Solenoid HS6B Subminiature Interlock Switches (07/03/12) ...

Page 2

... Switch with Solenoid Power Consumption by Solenoid + Indicator Actual Size (mm) Space saving design with angled connection cable HS6E RoHS directive compliant (2002/95/EC) The HS6E series subminiature interlock switches with solenoid do not contain lead, cadmium, mercury, hexavalent chromium, PBB, or PBDE. Space Saving (Approx. 30 mm) (07/03/12) ...

Page 3

... Virtually Limitless Mounting Options Sliding Doors Top Mounting Left-opening Front Mounting Left-opening Hinged Doors Top Mounting Left-opening Right-opening Side Mounting Up-opening (07/03/12) HS6E Top Mounting Actuator Right-opening Front Mounting Right-opening Side Mounting Left-opening Bottom Mounting Up-opening Right-opening 3 ...

Page 4

Manual Unlocking Possible from Three Directions The actuator can be unlocked manually with manual unlocks on either sides of the switch body depressing a plate. For details, see page 14. When unlocking with manual unlocks Optically enhanced lens ...

Page 5

... Common mounting holes - HS6E and HS6B • Common actuators - HS6E and HS6B Dimensions HS6E (with solenoid) 75 Mounting Hole Layout • Add one additional hole in the mounting panel for the HS6B, then the HS6E can be installed on the same panel. HS6E (with solenoid) 28 Common Actuators • ...

Page 6

... Conditional 50A (250V) Short-circuit Current (Use 250V/10A fast-blow fuse for short-circuit protection.) UL2464, No. 22 AWG Cable (12-core: 0.3 mm Cable Diameter ø7.6 mm Weight (approx.) 200g (HS6E-∗∗∗01) • Right-angle Actuator (SUS304) 2 (10G) 2 1000 m/s (100G Hz, amplitude 0. equivalent/core) (07/03/12) ...

Page 7

... Monitor Circuit Monitor Circuit Main Circuit Monitor Circuit Monitor Circuit Main Circuit Monitor Circuit Monitor Circuit: Cable Length Type No. 1m HS6E-L44B01-G 3m HS6E-L44B03-G 5m HS6E-L44B05-G 1m HS6E-M44B01-G 3m HS6E-M44B03-G 5m HS6E-M44B05-G 1m HS6E-N44B01-G 3m HS6E-N44B03-G 5m HS6E-N44B05-G 1m HS6E-P44B01-G 3m HS6E-P44B03-G 5m HS6E-P44B05-G 1m HS6E-L7Y4B01-G 3m HS6E-L7Y4B03-G 5m HS6E-L7Y4B05-G 1m HS6E-M7Y4B01-G 3m HS6E-M7Y4B03-G 5m HS6E-M7Y4B05-G 1m HS6E-N7Y4B01-G 3m HS6E-N7Y4B03-G ...

Page 8

... HS6E Subminiature Interlock Switches with Solenoid • Actuator Appearance Straight Actuator Right-angle Actuator Right-angle Actuator with Mounting Plate Angle Adjustable Actuator Angle Adjustable Actuator Type No. Development Circuit Code Door Monitor Lock Monitor Main Circuit Circuit Circuit L: 1NC+1NC 2NC 1NO M: 1NC+1NC 2NC ...

Page 9

... HS6E Subminiature Interlock Switches with Solenoid Dimensions • • • • Interlock Switch 5.5 10 46.1 41.8 28 When using straight actuator (HS9Z-A61) (12.6 ±1 ) (5) Actuator Stop (supplied) • Actuator Mounting Reference Position As shown in the figure on the right, the mounting reference position of the actuator when inserted in the interlock switch is: The actuator stop on the actuator lightly touches the interlock switch ...

Page 10

... HS6E Subminiature Interlock Switches with Solenoid Actuator Dimensions Straight Actuator (HS9Z-A61) Right-angle Actuator (HS9Z-A62) The tensile strength of the HS9Z-A62 actuator is 100N. When tensile force exceeding 100N is 20.9 43.2 expected, use the HS9Z-A62S actuator. (15. 0.8 When mounted (5.6) Note 1 2-ø9 Actuator Stop (supplied) Rubber Bushing Note: The actuator stop is used to adjust the actuator position ...

Page 11

... HS6E Subminiature Interlock Switches with Solenoid Circuit Diagrams and Operating Characteristics • Spring Lock Type Interlock Switch Status Door Status Circuit Diagram (Example: HS6E-N4) Door HS6E-L4 Main Circuit 11-42 Door Lock Monitor Monitor Door Monitor Circuit (door closed) 21-22 (+) (– Door Monitor Circuit ...

Page 12

... HS6E Subminiature Interlock Switches with Solenoid • Solenoid Lock Type Interlock Switch Status Door Status Circuit Diagram (Example: HS6E-N7Y) Door HS6E-L7Y Main Circuit 11-42 Door Lock Monitor Monitor Door Monitor Circuit (door closed) 21-22 (+) (– Door Monitor Circuit Main Circuit: (door closed) 31-32 ...

Page 13

... HS6E Subminiature Interlock Switches with Solenoid Safety Precautions • In order to avoid electric shock or fire, turn power off before installation, removal, wiring, maintenance, or inspection of the interlock switch. • If relays are used in the circuit between the interlock switch and the load, use only safety relays, since welded or stick- ing contacts of standard relays may invalidate the functions of the interlock switch ...

Page 14

... For Manual Unlocking Spring lock type The HS6E allows manual unlocking of the actuator to pre-check proper door operation before wiring or turning power on, as well as for emergency use such as a power failure. Solenoid lock type The HS6E can be unlocked manually in emergency. ...

Page 15

... HS6E Subminiature Interlock Switches with Solenoid Recommended Tightening Torque of Mounting Screws • Interlock switch: 1.0 to 1.5 N·m (three M4 screws) • Actuators: 1.0 to 1.5 N·m (two M4 screws) • The above recommended tightening torques of the mounting screws are the values with hex socket head bolts. When other screws are used and tightened to a smaller torque, make sure that the screws do not become loose after mounting ...

Page 16

HS6B Subminiature Interlock Switches World-class compactness with three poles of contacts. • World’s smallest switch: 30 × 30 × • Dual contacts and monitor contacts achieve the highest safety category (ISO 13849-1, EN 954-1) • Two actuator entry ...

Page 17

Dimensions • Interlock Switch 10.4 15 Slot Plug (Note 1) 5.5 (supplied) Note 1: Plug the unused actuator entry slot using the slot plug supplied with the interlock switch. • Using the HS9Z-A61 Straight Actuator (12.6 ) ±1 30.8 0.8 ...

Page 18

HS6B Subminiature Interlock Switches Contact Configuration and Operation Chart Type Contact Configuration Zb HS6B-11 1NC-1NO HS6B-02 2NC HS6B-12 2NC-1NO HS6B-03 21 3NC 31 Minimum Radius of Hinged Door • ...

Page 19

Safety Precautions • In order to avoid electric shock or fire, turn the power off before installation, removal, wiring, maintenance, or inspection of the switch. • If relays are used in the circuit between the interlock switch and the load, ...

Page 20

... BG standard in Germany Specifications and other descriptions in this catalog are subject to change without notice. IDEC CORPORATION (USA) 1175 Elko Drive, Sunnyvale, CA 94089-2209, USA Tel: +1-408-747-0550 / (800) 262-IDEC (4332) Fax: +1-408-744-9055 / (800) 635-6246 E-mail: opencontact@idec.com IDEC CANADA LIMITED Unit 22-151, Brunel Road, Mississauga, Ontario, ...