452EXE2SI-OL ABB, 452EXE2SI-OL Datasheet - Page 2

no-image

452EXE2SI-OL

Manufacturer Part Number
452EXE2SI-OL
Description
STARTR STR DLT 22KW 230V
Manufacturer
ABB
Datasheet

Specifications of 452EXE2SI-OL

No. Of Phases
Three
Power Rating
30hp
Current Rating
44A
Svhc
No SVHC (18-Jun-2010)
Coil Voltage Vac Nom
230V
Ip/nema Rating
IP65
Switching Ac3 Power Max
22kW
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
ABB Limited Tower Court, Foleshill Enterprise Park,
Courtaulds Way, Coventry. CV6 5NX
Tel: 02476 368500
Fax: 02476 364499
Connection Data
Circuit
Council of European Communities Directives: The products in this publication conform to relevant EEC Directives and EN Standards. Installation and use of such products must be carried out by competent, properly trained
personnel, complying with any instructions supplied by ABB. Liability for improper incorporation, assembly, use, processing, storing or handling of goods remains the sole responsibility of the individual, or company carrying out such
work. This publication is for information only. Whilst every care has been taken in the preparation of this leaflet, no liability is accepted for any consequence of its use. No licence to use any patent should be assumed. All dimensions
are approximate only and subject to change without notice, as are other technical features resulting from continual development and improvement.
E
Type 4 EXE2SI (400Vcoil)= = = =
=
=
=
=
pí~êJ J J J Delta
pí~ê
(main contactor in
Delta loop)
pí~ê
pí~ê
A1
L1
T1
96
L2
T2
Star
Stop/Reset
Overload
L3
T3
A2
95
14
13
Star
VE5-1
8
4
01
02
01
02
B
M
T
Start
E
M
L1 L2 L3
A1
L1
T1
U2
U1
7
3
Delta
T2
L2
V2 W2
V1 W1
3
M
L3
T3
A2
1
2
~
13
14
15
A2
3
4
16
5
6
TES5 Electronic Timer
Delta
W2
U2
V2
A1
T
L1
T1
T1
2
Overload
L2
Main
T2
T2
3 ~
4
M
18
A1
96
T3
L3
A2
02
02
14
14
95
T3
6
13
14
W1
V1
U1
S
M
D
S
L1
1
2
01
13
13 A2
01
Supply
L2
3
4
A2
A2
= = = = ==========
==========
==========Type 2 EXE2SI (230V coil)= = = =
==========
L3
D
M
5
6
S
Overload
Main
A1
A1
A1
N
400v
Control
230v
Control
E
A1
T1
L1
L2
T2
Star
T3
L3
A2
13
14
VE5-1
Modification for remote 2-wire control
Overload should be in
hand reset. Stop reset
button will only stop
motor whilst button is
depressed, if pressure
switch is closed.
01
02
01
02
Pressure
B
M
T
switch
E
96
L1 L2 L3
A1
L1
T1
Stop/Reset
Overload
U2
U1
Delta
T2
L2
95
V2 W2
V1 W1
3
M
L3
T3
A2
~
Star
N
8
4
13
14
Link
Start
M
7
3
A1
L1
T1
T1
2
Overload
L2
Main
T2
1
2
T2
4
96
L3
T3
A2
15
A2
3
4
95
T3
6
16
13
14
5
6
TES5 Electronic Timer
Delta
W2
V2
U2
T
3 ~
M
18
A1
02
02
14
14
W1
V1
U1
S
M
D
S
Conversion Chart
Note : Overload relay is
fitted in the delta loop. It is
therefore necessary to use
the conversion chart to
obtain correct overload
setting for a particular motor
full load current.
L1
2
1
Motor
full load
current
A
5
6
7
8
9
10
12
14
16
18
20
25
30
35
40
45
50
55
01
13
13 A2
01
Supply
L2
4
3
A2
A2
L3
S
D
M
ABB
5
6
Overload
Main
A1
A1
A1
N
400v
Control
230v
Control
Overload
setting
Delta loop
current A
2.9
3.5
4.0
4.6
5.2
5.8
7.0
8.1
9.3
10.4
11.6
14.5
17.4
20.3
23.2
26.1
29.0
32.0

Related parts for 452EXE2SI-OL