8536SAG12V02S SQUARE D, 8536SAG12V02S Datasheet - Page 16

Magnetic Motor Starter

8536SAG12V02S

Manufacturer Part Number
8536SAG12V02S
Description
Magnetic Motor Starter
Manufacturer
SQUARE D
Datasheet

Specifications of 8536SAG12V02S

No. Of Phases
Three
Power Rating
2hp
Current Rating
9A
Peak Reflow Compatible (260 C)
No
Supply Voltage Max
460VAC
Control Voltage Max
120V
Leaded Process Compatible
No
Switch Function
3PST
Supply Voltage Range
110VAC To 120VAC
Rohs Compliant
No
Contact Rating
9A
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
5/98
Auxiliary Units
Auxiliary contacts, power poles, and timer
attachments can be added by the factory or in the
field on all Type S starters and contactors. The
table below shows the maximum number of
auxiliary units (in addition to the holding circuit
contact) that can be added to a given size starter
or contactor. In addition, it is possible to add a
second internal contact on NEMA Size 0, 1, and 2
contactors and starters.
Factory Installed Auxiliary Contacts
Additional auxiliary contacts may be factory or
field added to any Type S contactor or starter. See
table above for maximum number of auxiliary
units. The table below lists the Form designations
for factory installed electrical contacts.
See Class 9999 for field modification kits.
Form Number of Additional Auxiliary
Contacts
When ordering factory installed auxiliary contacts,
the Form designations listed should be used.
NEMA
Size
00
0, 1 & 2
3, 4 & 5
6 & 7
Number of N.O.
Contacts
0
1
2
3
3
4
Type
SA
SB
SC
SD
SE
SF
SG
SH
SJ
No. of
Poles of
Basic
Contactor
2-3
1, 2 or 3
4 or 5
2-5
(Size 3 & 4)
2-3
(Size 5)
2-3
Number of N.C.
Contacts
1
2
3
4
0
1
2
3
0
1
2
0
1
0
Maximum Number of External
Auxiliary Units (In addition to
holding circuit contact)
4 single circuit auxiliary contacts (N.O. or N.C.)
if second internal auxiliary contact is not used.
4 single circuit auxiliary contacts (N.O. or N.C.)
3 single circuit auxiliary contacts (N.O. or N.C.)
plus 1 attached timer (ON or OFF delay).
2 single circuit auxiliary contacts (N.O. or N.C.)
plus 1 power pole adder (1 or 2 poles, N.O. or
N.C.).
1 attached timer (ON or OFF delay) plus 1
power pole adder (1 or 2 poles, N.O. or N.C.)
plus 1 auxiliary contact.
2 single circuit auxiliary contacts (N.O. or N.C.)
1 timer attachment plus 1 auxiliary contact.
4 single circuit auxiliary contacts (N.O. or N.C.)
2 single circuit (Sizes 3 & 4) or 3 single circuit
(Size 5) auxiliary contacts plus 1 attached timer
(ON or OFF delay).
2 single circuit auxiliary contacts (N.O. or N.C.)
plus 1 NEMA Size 0-1 or Size 2 power pole
adder (1 or 2 poles, N.O. or N.C.)
4 single circuit auxiliary contacts (N.O. or N.C.)
3 single circuit auxiliary contacts (N.O. or N.C.)
plus 1 attached timer (ON or OFF delay).
2 single circuit auxiliary contacts (N.O. or N.C.)
plus 1 NEMA Size 0-1 or Size 2 power pole
adder (1 or 2 poles, N.O. or N.C.)
© 1998 Square D All Rights Reserved
Form Number
X01
X02
X03
X04
X10
X11
X12
X13
X20
X21
X22
X30
X31
X40
Control Circuit Transformers
Class 9070 Type T machine tool control
transformers are normally used when it is
necessary to provide a lower voltage to the control
circuit. This transformer with fused protection may
be ordered from the factory by specifying Form
F4T. The addition of a transformer often requires
the use of a larger enclosure. The table below
shows the transformer selection for given sized
starters and contactors with or without auxiliary
units.
Power Poles
Single or double circuit power pole adders may be
factory or field installed on 2 and 3 pole Type S
contactors and starters. The table below lists the
Form designation for factory installed power pole
adders. Only one power pole adder may be
installed per contactor.
NEMA
Size
0 & 1
0 & 1
0 & 1
Mechanically
Interlocked
Devices
2
3
3
4
5
6, 7
j
u
Type
1 N.O.
1 N.C.
1 N.O., 1 N.C.
2 N.O.
2 N.C.
Application Data – Class 8502, 8536
Class 8502 & 8536 Type S, Size 3 standard NEMA Type 1, 4 and 12
enclosures have space for field mounting a fused control circuit
transformer. A Class 9070 Type GFT3 transformer and fuse block kit
is available for Form F4T requirements in a NEMA Type 1 enclosure.
NEMA Type 4 and 12 enclosures utilize a Class 9070 T150
transformer and a Class 9999 SF4 fuse block.
A Class 9070 transformer is an integral part of the Size 6 and Size 7
control circuit providing 120 volt control circuit voltage as standard.
Type
SB
SC
SB
SC
SB
SC
SD
SE
SE
SF
SG
SH,
SJ
NEMA Size
0, 1
2
0, 1
2
0, 1
2
0, 1
2
0, 1
2
No.
of
Poles
1-3
4 & 5
1-5
2-5
2-3
4 & 5
2-5
2-3
2-3
Auxiliary Units
With max. of 2 auxiliary
contacts
With timer and maximum of
1 auxiliary contact
With 3 or 4 auxiliary
contacts with timer and 2 or
3 auxiliary contacts
With or without auxiliary
contacts or timer
With or without attachments T100
With or without attachments T100
With or without attachments GO3j
With or without attachments T300
With or without attachments T300
Any
Any
Class 9999
Type
SB6
SB11
SB7
SB12
SB8
SB13
SB9
SB14
SB10
SB15
Form
Designation
Y428
Y436
Y429
Y437
Y435
Y440
Y430
Y438
Y434
Y439
Transformer
Class 9070
Type
T50
T100
T100
T500
u
15