No. Of Phases
Single Or Three
Power Rating
3.5kW
Current Rating
7A
Operating Temperature Range
-25°C To +50°C
Mounting Type
DIN Rail
Overload Adjustment Current Max
2.4A
Overload Adjustment Current Min
1.6A
Supply Voltage Max
24VDC
Frame Size
Standard
27.1
Ampacities of Insulated Conductors (Based on 2005 NEC)
Table 310.16. Allowable Ampacities of Insulated Conductors Rated 0–2000V, 60°–90°C [140°–194°F],
Not More Than Three Current-Carrying Conductors in Raceway or Cable or Earth (Directly Buried),
Based on Ambient Temperature of 30°C [86°F]
Size
AWG
kcmil
18
16
14
12
10
8
6
70
85
95
110
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
600
700
750
800
900
1000
1250
1500
1750
2000
Notes
V5-T27-238
Reprinted by permission from NFPA 70-2005. National Electrical Code
Unless otherwise specifically permitted elsewhere in this
for No. 10 copper; or 15A for No. 12 and 25A for No. 10 aluminum and copper-clad aluminum after any correction factors for ambient temperature and number of conductors have been applied.
Temperature Rating of Conductor. See NEC Table 310-13.
Copper
60°C [140°F]
Types
TW†, UF
20✝
25✝
30
40
55
85
100
115
130
125
145
165
195
215
240
260
280
320
355
385
400
410
355
385
400
410
435
455
495
520
545
560
Volume 5—Motor Control and Protection CA08100006E—May 2011 www.eaton.com
75°C [167°F]
Types
FEPW , RH , RHW ,
THHW , THW ,
THWN , XHHW ,
USE , ZW
20✝
25✝
35✝
50
65
95
110
130
150
150
175
200
230
255
285
310
335
380
420
460
475
490
420
460
475
490
520
545
590
625
650
665
IEC Contactors and Starters
XT IEC Power Control
90°C [194°F]
Types
TBS, SA, SIS, FEP , FEPB , MI,
RHH , RHW-2, THHN , THHW ,
THW-2 , THWN-2 , USE-2,
XHH, XHHW , XHHW-2, ZW-2
14
18
25†
30†
40†
55
75
55
65
75
85
170
195
225
260
290
320
350
380
430
475
520
535
555
475
520
535
555
585
615
665
705
735
750
, the overcurrent protection for conductor types marked with an obelisk (†) shall not exceed 15A for No. 14, 20A for No. 12 and 30A
®
, Copyright
©
2005. National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.
Aluminum or Copper-Clad Aluminum
60°C [140°F]
Types
TW , UF
20†
25
30
40
65
75
90
100
100
115
130
150
170
190
210
225
260
285
310
320
330
285
310
320
330
355
375
405
435
455
470
75°C [167°F]
Types
RH , RHW ,
THHW , THW ,
THWN , XHHW ,
USE
20†
30†
40
50
75
85
100
115
120
135
155
180
205
230
250
270
310
340
375
385
395
340
375
385
395
425
445
485
520
545
560
90°C [194°F]
Types
TBS, SA, SIS, THHN ,
THHW , THW-2, THWN-2,
RHH , RHW-2, USE-2, XHH,
XHHW, XHHW-2, ZW-2
25†
35†
45
60
4
3
2
1
135
150
175
205
230
255
280
305
350
385
420
435
450
385
420
435
450
480
500
545
585
615
630
Size
AWG
kcmil
12
10
8
6
70
85
95
110
1/0
2/0
3/0
4/0
250
300
350
400
500
600
700
750
800
600
700
750
800
900
1000
1250
1500
1750
2000

Related parts for XTAE007B10TD2P4