C200H-CN229-EU Omron, C200H-CN229-EU Datasheet - Page 6

no-image

C200H-CN229-EU

Manufacturer Part Number
C200H-CN229-EU
Description
Program Download Cable, For NT20S Graphical LCD Touch Screen, 1.6 Foot, 9 To 9, PC To NT
Manufacturer
Omron

Specifications of C200H-CN229-EU

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
J CHARACTERISTICS
Item
Control method
I/O control method
Programming language
Instruction length
Instructions
Execution time
Program capacity
Max. I/O capacity
Input bits
Output bits
Work bits
Special bits (SR area)
Temporary bits (TR area)
Holding bits (HR area)
Auxiliary bits (AR area)
Link bits (LR area)
Timers/Counters
Data memory
Interrupt
processing
High-speed
counter
Pulse output
Synchronized pulse control
Quick-response inputs
Input time constant
(ON response time = OFF response
time)
g
t
/
p
p
i
p
y
y
Read/Write
Read-only
PLC setup
External interrupts
Interval timer
interrupts
High-speed counter
Interrupt inputs
(Counter mode)
Basic instructions
Special instructions
Basic instructions
Special instructions
CPU Board only
With Expansion I/O
Boards
Counter interrupt
Counter interrupts
CPU Boards
With relay outputs
Stored program method
Cyclic scan with direct output; immediate refreshing can be performed with IORF(97)
Ladder diagram
1 step per instruction, 1 to 5 words per instruction
14
105 instructions, 185 variations
0.64 µs (LD instruction)
7.8 µs (MOV instruction)
4,096 words
32 points/40 points
168 points max.
IR 00000 to IR 00915 (words not used for input bits can be used for work bits)
IR 01000 to IR 01915 (words not used for output bits can be used for work bits)
928 bits: IR 02000 to IR 04915 and IR 20000 to IR 22715
448 bits: SR 22800 to SR 25515
8 bits (TR0 to TR7)
320 bits: HR 0000 to HR 1915 (Words HR 00 to HR 19)
384 bits: AR 0000 to AR 2315 (Words AR 00 to AR 23)
256 bits: LR 0000 to LR 1515 (Words LR 00 to LR 15)
256 timers/counters (TIM/CNT 000 to TIM/CNT 255)
2,048 words (DM 0000 to DM 2047) The Error Log is contained in DM 2000 to DM 2021
456 words (DM 6144 to DM 6599)
56 words (DM 6600 to DM 6655)
4 (also used for external interrupt inputs in counter mode and quick-response inputs)
1 (Scheduled Interrupt Mode or Single Interrupt Mode)
1 (20 kHz single-phase or 5 kHz two-phase (linear count method))
1 (set value comparison or set-value range comparison)
4 inputs (also used for interrupt inputs and quick-response inputs)
4 (also used for the external interrupt inputs and quick-response inputs)
2 points with no acceleration/deceleration, 10 Hz to 10 kHz each, and no direction control
1 point with trapezoidal acceleration/deceleration, 10 Hz to 10 kHz, and direction control
2 points with variable duty-ratio outputs
(Pulse outputs can be used with transistor outputs only, they cannot be used with relay
outputs)
1 point:
A pulse output can be created by combining the high-speed counter with pulse outputs and
multiplying the frequency of the input pulses from the high-speed counter by a fixed factor
(This output is possible with transistor outputs only, it cannot be used with relay outputs)
4 points (Min. input pulse width: 50 µs max.) (Also used for interrupt inputs and for interrupt
inputs in counter mode)
Can be set for all input points
(1 ms, 2 ms, 3 ms, 5 ms, 10 ms, 20 ms, 40 ms, or 80 ms)
This constant, however, is fixed to 1 ms for 40 and 64 I/O-point Expansion I/O Boards
(This table continues on the next page.)
1-ms timers: TMHH(—)
10-ms timers: TIMH(15)
100-ms timers: TIM
1-s/10-s timers: TIML(—)
Decrementing counters: CNT
Reversible counters: CNTR(12)
Micro Controller Board
With transistor outputs
CPM2B
A--75

Related parts for C200H-CN229-EU