DPM125-BL LASCAR, DPM125-BL Datasheet

LCD MODULE, 3.5DIGIT

DPM125-BL

Manufacturer Part Number
DPM125-BL
Description
LCD MODULE, 3.5DIGIT
Manufacturer
LASCAR
Datasheet

Specifications of DPM125-BL

Supply Voltage Range
7.5VDC To 14VDC
No. Of Digits / Alpha
3.1/2
Display Size
31mm X 14mm
Panel Cutout Height
22.2mm
Panel Cutout Width
45mm
Operating Temperature Range
0°C To +50°C
Svhc
No SVHC
Accuracy
0.1% ±
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
PANEL FITTING
Fit the bezel to the front of the panel and then locate the
meter into the bezel from behind. Alternatively the
meter and bezel may be assembled before fitting into
the front of the panel but care must be taken not to use
excessive force. Finally fit the window into the front of
the bezel.
INSERTION DANS UN PANNEAU
Approchez le cadre par l’avant du panneau et le module
par l’arrière. Alternativement le module et le cadre
peuvent être assemblés avant l’insertion dans le
panneau mais vous devez veiller à ne pas forcer.
Finalement, insérez la glace sur l’avant du cadre.
Specifications liable to change without prior warning
Spécifications peuvent changer sans préavis
Die technischen Daten können ohne vorherige Ankündigung geändert werden
Specifiche soggette a variazione senza preavviso
DIMENSIONS
All dimensions in mm (inches)
Panel cut-out 45 x 22.2 (1.77 x 0.87)
DIMENSIONS
Toutes les dimensions sont en mm (pouces)
Découpe panneau 45 x 22,2 (1,77 x 0,87)
b. 9.00 (0.35)
d. 7.50 (0.30)
a. 1.50 (0.06)
c. 10.4 (0.41)
e. 2.54 (0.10)
d
12
40.5 (1.59)
38.0 (1.50)
48 (1.89)
e
g. 5.00 (0.20)
h. 1.60 (0.06)
f. 0.50 (0.02)
i. 2.50 (0.10)
j. 8.25 (0.32)
f
1
a
8
DPM 125-BL Issue 5
DPM 125-BL Edition 5
DPM 125-BL
DPM 125-BL
EINBAUHINWEISE
Bauen Sie die Fassung von vorne in die Frontplatte ein,
und setzen Sie danach das Meßgerät von hinten in die
Fassung ein. Das Meßgerät und die Fassung können auch
vor dem Einbau zusammengebaut werden, dabei muß
jedoch darauf geachtet werden, daß keine Gewalt
angewandt wird. Zu letzt kann das Fenster von vorne in
die Fassung eingesetzt werden.
MONTAGGIO SU PANNELLO
Montare la cornice sulla parte anteriore del pannello e
posizionare il contatore all’interno della cornice
inserendolo dalla parte posteriore. In alternativa, il
contatore e la cornice possono essere assemblati prima
di essere montati sulla parte anteriore del pannello, ma
in questo caso prestare attenzione a non applicare una
pressione eccessiva. Infine, montare la finestra sulla
parte anteriore della cornice.
g
b
h
ABMESSUNGEN
Alle Abmessungen in mm (Zoll)
Einbauausschnitt
DIMENSIONI
Tutte le dimensioni sono espresse in mm (pollici)
Finestra pannello
i
j
Ausgabe 5
Versione 5
Viewing Area showing display in TEST mode
Affichage en mode TEST
Sichtfläche mit der Anzeige im Testmodus
Area di visualizzazione illustrante il display nella
modalità TEST
ON BOARD SOLDER LINKS
LIAISONS A SOUDER
ZINNBRÜCKEN AUF DER PLATINE
COLLEGAMENTI INCORPORATI MEDIANTE
SALDATURA
November/1999
novembre/1999
November/1999
Novembre/1999
12
LK1
LK2
45 x 22,2 (1,77 x 0,87)
45 x 22,2 (1,77 x 0,87)
31.0 (1.22)
M.C. Applies to DPM 125-BL/3
M.C. Applique à DPM 125-BL/3
M.C. Gilt für
M.C. Applicabile a
DPM 125-BL/3
DPM 125-BL/3
1
www.lascarelectronics.com
LASCAR ELECTRONICS LIMITED,
E-MAIL: lascar@netcomuk.co.uk
DPM 125-BL
WHITEPARISH, SALISBURY,
TEL: +44 (0)1794 884567
FAX: +44 (0)1794 884616
WILTSHIRE SP5 2SJ UK
MODULE HOUSE,
3½ Digit LCD Module
Module Miniature LCD 3½
Caractères
3½-stelliges LCD-Modul
Modulo con display LCD a 3,5
cifre
LASCAR ELECTRONICS, INC.
E-MAIL: lascarus@pacbell.net
PALO ALTO, CA 94303-0727
TEL: +1 (650) 838 9027
FAX: +1 (650) 833 5432
PO BOX 50727,
1

Related parts for DPM125-BL

DPM125-BL Summary of contents

Page 1

... DPM 125-BL/3 3½ Digit LCD Module Module Miniature LCD 3½ Caractères 3½-stelliges LCD-Modul Modulo con display LCD a 3,5 cifre LASCAR ELECTRONICS, INC. MODULE HOUSE, PO BOX 50727, PALO ALTO, CA 94303-0727 TEL: +1 (650) 838 9027 FAX: +1 (650) 833 5432 E-MAIL: lascarus@pacbell.net ...

Page 2

This compact LCD DPM uses advanced components and construction techniques to provide an unrivalled combination of high performance and low cost. For poor visibility, a long life LED backlight is fitted. • 12.5mm (0.5“) Digit Height • Logic Selectable Decimal ...

Page 3

Specification Min. Typ. Max. Unit Accuracy (overall error) * 0.05 0.1 %(±1 count) Linearity ±1 count Sample rate 3 samples/sec Operating temperature range 0 50 °C Temperature stability 100 ppm/°C Supply voltage (V+ to V Supply ...

Page 4

Fortschrittliche Komponenten und Bauweise verleihen diesem LCD-DPM eine einzigartige Kombination von hoher Leistung und günstiger Preislage. Zum Einsatz bei ungünstiger Beleuchtung wird der Hintergrund der LECD beleuchtet. • Ziffernhöhe 12,5 mm (0,5") • Durch die Logik wählbarer Dezimalpunkt • Automatische ...

Related keywords