SP 300-BLUE LASCAR, SP 300-BLUE Datasheet

VOLTMETER, LCD, 3.5DIGIT

SP 300-BLUE

Manufacturer Part Number
SP 300-BLUE
Description
VOLTMETER, LCD, 3.5DIGIT
Manufacturer
LASCAR
Datasheet

Specifications of SP 300-BLUE

Supply Voltage Range
4.75V To 5.25V
Backlighting Colour
Blue
No. Of Digits / Alpha
3.1/2
Display Size
33mm X 20.5mm
Panel Cutout Height
21.3mm
Panel Cutout Width
34.1mm
Operating Temperature Range
0°C
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
SP 300-BLUE
LASCAR ELECTRONICS LTD.
MODULE HOUSE
WHITEPARISH
WILTSHIRE
UK
TEL: +44 (1794) 884567
FAX: +44 (1794) 884616
E-mail: sales@lascar.co.uk
Specifications liable to change without prior warning
PRODUCT DESCRIPTION
The SP 300-BLUE features a 200mV d.c. measurement range with auto-zero and auto-polarity. Decimal points are
user selectable. The SP 300-BLUE features a negative rail generator which enables the meter to measure a signal
referenced to its own power supply 0V. The blue LED display ensures excellent readability under low light conditions.
The module is easily fitted into the panel, using the fixing clip provided. The module's low cost means it will suit high
and low volume applications. The design of the panel meter's housing and seal ensures splash proofing in many
applications.
FEATURES
TYPICAL APPLICATIONS
• Precision Instrumentation Systems
• Power Supply Monitoring
• Test Boxes
• Panel-Mount Indication
ELECTRICAL SPECIFICATIONS
SAFETY
To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s pins must not exceed
60Vdc. The user must ensure that the incorporation of the panel meter into the user’s equipment conforms to the
relevant sections of BS EN 61010 (Safety Requirements for Electrical Equipment for Measuring, Control and
Laboratory Use).
• Blue LED Display
• 200mV d.c. Full Scale Reading
• 50mA @ +5V d.c. Power Supply
• Simplified Connection
• Splash Proof
Specification
Accuracy (overall error) *
Linearity
Sample rate
Operating temperature range
Warm-up time
Temperature stability
Supply voltage
Supply current
Input leakage current (Vin = 0V)
* To ensure maximum accuracy, re-calibrate periodically.
9.4mm (0.37") Digit Height
Auto-zero and Auto-polarity
Programmable Decimal Points
SP5 2SJ
www.lascarelectronics.com
LASCAR ELECTRONICS INC.
3750 West 26th Street
Erie
PA 16506
USA
TEL: +1 (814) 835 0621
FAX: +1 (814) 838 8141
E-mail: us-sales@lascarelectronics.com
SP 300-BLUE
Min.
4.75
0
ORDERING INFORMATION
Issue 4
Standard Meter
Typ.
150
0.1
2.5
10
50
5
1
SEP/2005
3½ Digit LED Voltmeter Module
Max.
5.25
±1
50
10
M.C.
LASCAR ELECTRONICS (HK) LIMITED
FLAT C, 5/FL., LUCKY FTY. BLDG.
63-65 HUNG TO ROAD
KWUN TONG
HONG KONG
TEL: +852 2797 3219
FAX: +852 2343 6187
E-mail: b4lascar@samsongroup.com.hk
Applies to SP 300/1
% (±1 count)
samples/sec
ppm/°C
minute
Stock Number
SP 300-BLUE
count
Unit
mA
pA
°C
V
KOWLOON
Page 1 of 4
Page 2 of 4
Page 2 of 4

Related parts for SP 300-BLUE

SP 300-BLUE Summary of contents

Page 1

... The SP 300-BLUE features a 200mV d.c. measurement range with auto-zero and auto-polarity. Decimal points are user selectable. The SP 300-BLUE features a negative rail generator which enables the meter to measure a signal referenced to its own power supply 0V. The blue LED display ensures excellent readability under low light conditions. ...

Page 2

... A Specifications liable to change without prior warning Panel thickness: 1.0 - 3.0 (0.04 - 0.12) Panel 2 PIN CONFIGURATION 8 1 DP3 300-BLUE Issue 4 www.lascarelectronics.com 3½ Digit LED Voltmeter Module a b 27.9 (1.10) 2.54 (0.1) 33.0 (1.30) a. 0.75 (0.03) b. 10.00 (0.39) c. 6.00 (0.24) Fixing Clip ...

Page 3

... V- is -5V. When measuring with the input referenced to the same supply rail as that of the panel meter, then the limitations on the input range are (V- + 1.5V) to (V+ - 1.5V). Solder Links: LCOM Normally Open. Connects IL to COM. Specifications liable to change without prior warning SP 300-BLUE Issue 4 SEP/2005 www.lascarelectronics.com 3½ Digit LED Voltmeter Module 8 ...

Page 4

... Rb= Shunt Rs = 200mV W (e.g. 0.1 / 400mW for 2A full scale) I FSR SP 300-BLUE Issue 4 www.lascarelectronics.com 3½ Digit LED Voltmeter Module Vin 300-BLUE Set Zero 1 220k COM 4-20mA current loop Measuring a 4-20mA loop current. R= Reading at 20mA 160 The meter's power supply must be isolated from the 4-20mA current loop ...