LPAX0600 Red Lion Controls, LPAX0600 Datasheet - Page 2

Multifunction Meter

LPAX0600

Manufacturer Part Number
LPAX0600
Description
Multifunction Meter
Manufacturer
Red Lion Controls
Type
Counter/Rate Indicatorr
Datasheet

Specifications of LPAX0600

No. Of Digits / Alpha
6
Panel Cutout Height
3.63"
Panel Cutout Width
9.29"
Signal Input Type
Count And Rate, Serial Slave
Application
For industrial
Connection Type
Cage-Clamp
Cut Out, Panel
9.29×3.63 "
Digit Height
1.5
Dimensions
10"L×4.77"W×4.75"H
Display Digit Height
1.5 "
Display Type
LED
Function
Counter/Rate Indicator/Serial Slave
Humidity
0 to 85%
Material, Casing
Steel
Number Of Digits
5
Primary Type
Electronic
Range, Measurement
-99999 to 999999
Temperature, Operating
0 to +50 °C
Termination
Cage Clamp
Voltage, Input
85 to 250 VAC
Voltage, Supply
85 to 250 VAC/11 to 36 VDC or 24 VAC
Sealing
NEMA 4/IP65
Character Size
1.5"
Color
Red
Ip/nema Rating
IP65 / NEMA 4
Rohs Compliant
Yes
For Use With
Red Lion MPAXI000, MPAXC000 And MPAXR000 MPAX Modules
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
PAXCDC10 - RS485 Serial (Terminal)
PAXCDC1C - RS485 Serial (Connector)
PAXCDC20 - RS232 Serial (Terminal)
PAXCDC2C - RS232 Serial (Connector)
7. ENVIRONMENTAL CONDITIONS:
8. MOUNTING REQUIREMENTS:
9. MODULE INSTALLATION:
About the MPAX Input Modules
scaling which allows the LPAX to display most any engineering unit. Once the MPAX is inserted into the LPAX, the unit has the same functions and capabilities of
our PAX Series Intelligent Panel Meters. A full set of PAX programming instructions will be included with the MPAX module.
Note: The MPAX provides the operating power for the LPAX, therefore you must select either the AC or DC MPAX corresponding with your application and available
Selecting Your Display Components and Option Cards
Please use the following chart to identify the appropriate MPAX module (including supply power) and LPAX Display that will satisfy your application.
OPTIONAL PLUG-IN CARDS AND ACCESSORIES
Adding Option Cards
However, only one card from each function type can be installed at a time. The
function types include Setpoint Alarms (PAXCDS), Communications
(PAXCDC), and Analog Output (PAXCDL). The cards can be installed initially
or at a later date. Each optional plug-in card is shipped with installation and
programming instructions.
COMMUNICATION CARDS (PAXCDC)
series. Only one of these cards can be installed at a time. When programming
the unit via Crimson (for MPAXI) or SFPAX (for MPAXCK or MPAXTM), the
RS232 or RS485 Cards must be used.
SETPOINT CARDS (PAXCDS)
these cards can be installed at a time. (Logic state of the outputs can be reversed
in the programming.) These plug-in cards include:
Operating Temperature Range: Determined by the MPAX module
Storage Temperature Range: -40 to 60°C
Operating and Storage Humidity: 0 to 85% max. RH (non-condensing)
Altitude: Up to 2000 meters
Max. panel thickness is 0.375" (9.5 mm)
Min. panel thickness for NEMA 4/IP65 sealing is 0.060" (1.57 mm)
24-pin shrouded connector on LPAX engages connector on MPAX module
upon installation. Shroud ensures proper alignment by providing a lead-in for
the module connector.
The MPAX Module serves as the input to the LPAX Display. There are several different modules to cover a variety of inputs. The MPAX module provides input
power.
To build a complete display unit, you will need an LPAX and an MPAX Input Module. The LPAX is only a display and will not operate without an MPAX module.
The MPAX series meters can be fitted with up to three optional plug-in cards.
A variety of communication protocols are available for the PAX and MPAX
The MPAX series has four setpoint alarm output plug-in cards. Only one of
Dual relay, FORM-C, Normally open & closed
Quad relay, FORM-A, Normally open only
Isolated quad sinking NPN open collector
Isolated quad sourcing PNP open collector
WARNING: Disconnect all power to the unit before
**The LPAXCK will only operate with the Clock/Timer MPAX input module.
installing Plug-in cards.
*For detailed module and plug-in card specifications, see corresponding PAX literature. (i.e. For MPAXI specifications, see the PAXI literature)
Count/Rate/Serial Slave
Count
Rate
Clock/Timer
Timer
SIGNAL TYPE
PAXCDC30 - DeviceNet
PAXCDC40 - Modbus (Terminal)
PAXCDC4C - Modbus (Connector)
PAXCDC50 - Profibus-DP
MPAXCK00
MPAXTM00
MPAXC000
MPAXR000
85-250 VAC
MPAXI000
MPAX MODULES
11 to 36 VDC / 24 VAC
MPAXTM10
MPAXC010
MPAXR010
MPAXCK10
MPAXI010
*
2
LPAXCK00
LPAXCK00
LPAX0600
LPAX0600
LPAX0600
DISPLAYS
10. CONNECTIONS: All wiring connections are made to the MPAX module
11. CONSTRUCTION: Steel front panel, enclosure, and rear cover with
12. WEIGHT: 2.7 lbs (1.2 kg) (less module)
LINEAR DC OUTPUT (PAXCDL)
from the analog output plug-in card. The programmable output low and high
scaling can be based on the input, max, min, or total display value. Reverse
slope output is possible by reversing the scaling point positions.
PROGRAMMING SOFTWARE
CRIMSON - MPAXI Only
LPAX meter from a PC. Crimson offers standard drop-down menu commands,
that make it easy to program the LPAX meter. The LPAX program can then be
saved in a PC file for future use. A PAX serial plug-in card is required to
program the meter using the software.
SFPAX - MPAXCK and MPAXTM Only
LPAX meter from a PC. Using the SFPAX makes it easier to program the LPAX
meter and allows saving the PAX program in a PC file for future use. On-line
help is available within the software. A PAX serial plug-in card is required to
program the meter using the software.
LPAX
via high compression cage-clamp terminal blocks. Wiring instructions are
provided with the MPAX module.
textured black polyurethane paint for scratch and corrosion resistance
protection. Sealed front panel meets NEMA 4/IP65 specifications for indoor
use when properly installed. Installation Category II, Pollution Degree 2.
Panel gasket and keps nuts included.
Either a 0(4)-20 mA or 0-10 V retransmitted linear DC output is available
Crimson is a Windows
The SFPAX is a Windows
PAXCDL10 - Retransmitted Analog Output Card
**
**
CAUTION: DISCONNECT ALL POWER BEFORE
INSTALLING OR REMOVING MODULE
SETPOINT
YES
YES
YES
YES
YES
OPTIONAL PLUG-IN CARD COMPATABILITY
®
COMMS
YES
YES
YES
based program that allows configuration of the
®
-
-
based program that allows configuration of the
ANALOG
YES
-
-
-
-
REAL-TIME
CLOCK
YES
-
-
-
-

Related parts for LPAX0600