Accuracy:
Technology: Moving Iron, Moving Coil
Description: Four sizes: 48mm, 72mm, 80mm and 96mm. Mounting depth 43mm. Multiple mounting methods: flush mount with bracket,
AC Ammeters- Moving Iron (T), 90º Scale
USE OF CURRENT TRANSFORMER WITH A 5 AMP SECONDARY RECOMMENDED OVER 10AMPS
* ACCURACY 2.5 % ON HIGH CURRENT MODELS WHEN CONNECTED DIRECT WITHOUT CURRENT TRANSFORMER
EXPLOSIVE GAS ATMOSPHERE MODEL ALSO AVAILABLE (E)
AC Voltmeters- Moving Iron (T), 90º Scale
AC Ammeters- Moving Coil w/Rectifier (L),
90º or 240º Scale
USE OF CURRENT TRANSFORMER WITH A 5 AMP SECONDARY RECOMMENDED OVER 10AMPS
* ACCURACY 2.5 % ON HIGH CURRENT MODELS WHEN CONNECTED DIRECT WITHOUT CURRENT TRANSFORMER
THESE METERS ARE SCALED IN R.M.S. VALUES, AVAILABLE 72 MM AND LARGER ONLY
XX
INDICATES SIZE IN MM
48MM,72MM,80MM AND 96MM
RANGE
0-100 Milli Amps
0-500 Milli Amps
0-1 Amps
0-7.5 Amps
0-10 Amps
0-15 Amps
0-20 Amps
0-25 Amps
0-30 Amps
0-40 Amps
0-50 Amps
0-60 Amps*
0-75 Amps*
0-100 Amps*
RANGE
0-30 Volts
0-50 Volts
0-75 Volts
0-100 Volts
0-120 Volts
0-150 Volts
0-200 Volts
0-250 Volts
0-450 Volts
450-450KV meters can use potential transformer with secondary
RANGE
0-500 Milli Amps
0-1 Amps
0-1.5 Amps
0-3 Amps
0-5Amps
0-7.5 Amps
0-10 Amps
0-15 Amps
0-20 Amps
1.5%-2.5%
snap-in (small sizes), mosanic board and slippage mount. Zero adjust, field replaceable scales without opening the case (90º scale)
voltage of 100 volts
Y
S Q U A R E M E T E R C P S E R I E S
PART #
CP-TxxA-.1A-AC-y
CP-TxxA-.5A-AC-y
CP-TxxA-1A-AC-y
CP-TxxA-7.5A-AC-y
CP-TxxA-10A-AC-y
CP-TxxA-15A-AC-y
CP-TxxA-20A-AC-y
CP-TxxA-25A-AC-y
CP-TxxA-30A-AC-y
CP-TxxA-40A-AC-y
CP-TxxA-50A-AC-y
CP-TxxA-60A-AC-y
CP-TxxA-75A-AC-y
CP-TxxA-100A-AC-y
PART #
CP-TxxV-30V-AC-y
CP-TxxV-50V-AC-y
CP-TxxV-75V-AC-y
CP-TxxV-100V-AC-y
CP-TxxV-120V-AC-y
CP-TxxV-150V-AC-y
CP-TxxV-200V-AC-y
CP-Txx-250V-AC-y
CP-TxxV-450V-AC-y
PART #
CP-LxxA-1A-AC-y
CP-LxxA-1.5A-AC-y
CP-LxxA-3A-AC-y
CP-LxxA-5A-AC-y
CP-LxxA-7.5A-AC-y
CP-LxxA-10A-AC-y
CP-LxxA-15A-AC-y
CP-LxxA-20A-AC-y
CP-LxxA-.5A-AC-y
INDICATES MOUNTING TYPE
I-FLUSH MOUNT W/BRACKET
II-MOSANTIC
III-DIN RAIL
IV-SLIPPAGE
V - SCREW MOUNT
AC Voltmeters- Moving Coil w/Rectifier (L),
90º or 240º Scale
AVAILABLE 72 MM AND LARGER ONLY
FOR VOLTAGE OVER 450 VOLTS USE AN EXTERNAL RESISTOR
DC Ammeters- Moving Coil (C), 90º or 240º Scale
* ACCURACY 2.5 % ON HIGH CURRENT MODELS WHEN CONNECTED DIRECT WITHOUT CURRENT TRANSFORMER
FOR CURRENT OVER 10 AMPS THE USE OF AN EXTERNAL SHUNT IS RECOMMENDED.
RANGE
0-3 Volts
0-5 Volts
0-7.5 Volts
0-10 Volts
0-15 Volts
0-20 Volts
0-30 Volts
0-50 Volts
0-100 Volts
0-150 Volts
0-200 Volts
0-250 Volts
0-300 Volts
0-400 Volts
0-450 Volts
RANGE
0-100 Micro Amps
0-500 Micro Amps
0-1 Milli Amps
0-2 Milli Amps
0-5 Milli Amps
0-10 Milli Amps
0-20 Milli Amps
0-30 Milli Amps
0-50 Milli Amps
0-75 Milli Amps
0-100 Milli Amps
0-150 Milli Amps
0-200 Milli Amps
0-250 Milli Amps
0-300 Milli Amps
0-500 Milli Amps
0-1 Amps
0-3 Amps
0-7.5 Amps
0-10 Amps
0-20 Amps
0-30 Amps
0-50 Amps
0-60 Amps
0-75 Amps
0-100 Amps
S Q U A R E M E T E R C P S E R I E S
www.shuritemeters.com • 203-481-5721
PART #
CP-LxxV-3V-AC-y
CP-LxxV-5V-AC-y
CP-LxxV-7.5V-AC-y
CP-LxxV-10V-AC-y
CP-LxxV-15V-AC-y
CP-LxxV-20V-AC-y
CP-LxxV-30V-AC-y
CP-LxxV-50V-AC-y
CP-LxxV-100V-AC-y
CP-LxxV-150V-AC-y
CP-LxxV-200V-AC-y
CP-LxxV-250V-AC-y
CP-LxxV-300V-AC-y
CP-LxxV-400V-AC-y
CP-LxxV-450V-AC-y
PART #
CP-CxxA-100uA-DC-y
CP-CxxA-500uA-DC-y
CP-CxxA-1mA-DC-y
CP-CxxA-2mA-DC-y
CP-CxxA-5mA-DC-y
CP-CxxA-10mA-DC-y
CP-CxxA-20mA-DC-y
CP-CxxA-30mA-DC-y
CP-CxxA-50mA-DC-y
CP-CxxA-75mA-DC-y
CP-CxxA-100mA-DC-y
CP-CxxA-150mA-DC-y
CP-CxxA-200mA-DC-y
CP-CxxA-250mA-DC-y
CP-CxxA-300mA-DC-y
CP-CxxA-500mA-DC-y
CP-CxxA-1A-DC-y
CP-CxxA-3A-DC-y
CP-CxxA-7.5A-DC-y
CP-CxxA-10A-DC-y
CP-CxxA-20A-DC-y
CP-CxxA-30A-DC-y
CP-CxxA-50A-DC-y
CP-CxxA-60A-DC-y
CP-CxxA-75A-DC-y
CP-CxxA-100A-DC-y
3