Multifunction Counter

V45450-1

Manufacturer Part Number
V45450-1
Description
Multifunction Counter
Manufacturer
VEEDER ROOT
Type
Counterr
Datasheets

Specifications of V45450-1

No. Of Digits / Alpha
4
Digit Height
10mm
Counting Speed
10kHz
Operating Temperature Range
0°C To +55°C
Character Size
10mm
Panel Cutout Width
1.77"
Connection Type
Screw
Counter Type
Predetermining
Cut Out, Panel
1/16 DIN
Dimensions
1.89"L×4.33"W×1.89"H
Display Digit Height
10mm (Top Display), 7mm (Bottom Display)
Display Type
LED
Frequency, Operating
50⁄60 Hz
Function
Counter
Input Type
NPN
Mounting Type
Panel
Number Of Digits
6
Primary Type
Electronic
Standards
UL and cUL Recognized, CE Marked
Temperature, Operating, Range
0 to +50 °C
Terminal Type
Screw Terminal
Termination
Screw Terminal
Voltage, Supply
90 to 264 VAC
Weight
7 Oz.
Input Signals Accepted From A Variety Of Sources
Dry Contact, PNP or NPN Sensors, Encoders
Lead Free Status / RoHS Status
na
R
O
N
E
L
E
C
T
C
I
5
M
R
S
T
E
M
I
T
E
R
S
I
5.24
The SX160 is a microprocessor based control that combines a repeat
cycle timer with an internal batch counter. The batch counter counts
the number of repeat cycle operations that the timer performs. The
batch counter has its own programmable output and automatically stops
the repeat cycle timer operation after the user programmed number of
cycles.
The repeat cycle timer function has a SPDT relay output. The setpoints
for the output ON and OFF times are individually programmable. There
are eight time ranges available for the repeat timer function from 99.99
seconds to 999.9 hours.
The internal batch counter has its own SPDT relay output with two
programmable operating modes. The batch counter output can operate
in either an ON-Delay or Interval mode. The batch counter can be set
to allow from 1 to 9999 cycles, or it can be set to provide continuous
repeat cycle operation.
The SX160 is housed in a standard DIN case (68mm square cutout).
The case and front bezel require minimal panel space yet provide easy
to use programming keys and an easy to read .36 inch LED display.
The operating modes and time ranges for the unit are programmed
using rocker switches on the back of the unit. This programming
method provides both simplicity and security. The front panel display
has a prompted programming routine that prompts the user when to
program the ON and OFF times as well as the batch counter setpoint.
Some of the other features of the SX160 timer include:
NEMA 4 Hosedown Test rated
Two 5 amp SPDT relay outputs
Two output operating modes for the repeat cycle timer
Two output operating modes for the batch counter
Eight time ranges for the ON and OFF time
Time inhibit input
LED indicators for output status
Setpoint to zero or zero to setpoint cycle progress indication
Front panel and remote reset inputs
Keypad lock function
Nonvolatile memory (NOVRAM) for program and data retention
Removable terminal blocks for wiring connections
EAGLE SIGNAL
Electronic Timers
VEEDER-ROOT • EAGLE SIGNAL • DYNAPAR
brand
SX160 Dual Setpoint Repeat Cycle
SPECIFICATIONS
Time Ranges:
Operating Voltage/Frequency: A6 - 120 VAC, 50/60 Hz
Batch Counter Range: 1-9999 or continuous
Setting Accuracy: Time:
Repeat Accuracy: Time:
Reset Time: 15 ms
Power on Response: 200 ms max.
Operating Temperature: +32° to +122°F (0° to +50°C)
Sensor Power Supply: +12 VDC, 75 milliamps
Output Rating: Relay: 5 amp (resistive), 10 to 264 VAC
Vibration: Unit function is unaffected by 2.5
Static Discharge: Unit function is unaffected by a constant 3600 volt peak,
Transient Protection: Immune to 2500 volts peak transients up to 50
B6 - 240 VAC, 50/60 Hz
Count: 100%
Count: 100%
tude in both directions of the perpendicular mounting axes imposed from
10 to 100 Hz
60 Hz discharge applied to the grounded front plate at a relative humidity
of less than 25%
microseconds in duration
Repeat cycle timer
and batch counter
combined in a
compact package...
can control time cycle
length plus number of
cycles
Sym.
1
2
3
4
5
6
7
8
0.001% of setting or 35 ms, whichever is larger
0.05% of setting or 50 ms, whichever is larger
99 Min.: 59 Sec.
99 Hr.: 59 Min.
Maximum
99.99 Sec.
999.9 Sec.
99.99 Min.
999.9 Min.
Range
99.99 Hr.
999.9 Hr.
G
sinusoidal vibration magni-
Minimum
Setting
.01 Sec.
.01 Min.
.1 Sec.
.1 Min.
.01 Hr.
1 Sec.
1 Min.
.1 Hr.

Related parts for V45450-1