M235-1-0-46-0 Simpson, M235-1-0-46-0 Datasheet - Page 2

Current Meter

M235-1-0-46-0

Manufacturer Part Number
M235-1-0-46-0
Description
Current Meter
Manufacturer
Simpson
Type
Ammeterr
Datasheets

Specifications of M235-1-0-46-0

No. Of Digits / Alpha
3-1/2
Meter Function
AC Ammeter
Meter Range
0A To 5A
Digit Height
12.7mm
Power Consumption
4VA
Operating Temperature Range
0°C To +55°C
Sample Rate
3 SPS
Meter Signal Input
Current
Accuracy
±0.5% %
Connection Type
Screw
Current Rating
5 A
Cut Out, Panel
0.88×2.68 "
Depth
2.36 in.
Dimensions
2.84"L×2.36"W×0.95"H
Display Digit Height
0.5 "
Display Resolution
10 mA
Display Type
LCD
Function
Ammeter
Indicator Type
3-1⁄2 Digit
Material, Casing
Thermoplastic
Meter Type
Digital
Number Of Digits
3-1/2
Primary Type
Electronic
Range, Measurement
5 A
Temperature, Operating
0 to 55 °C
Voltage, Supply
85 to 250 VAC
Equipment Type
AC Current Meter
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
DISPLAY
Type: 7-segment LCD
Height:
Decimal point:
Overrange indication: Most significant
digit =“1”
Backlighting: Optional negative image, red
backlighting
Polarity: Auto with “-” indication, “+” implied
POWER REQUIREMENTS
AC Volt: 85-250VAC @40-440Hz
DC Volt: 9-32VDC
Power Consumption:
85-250VAC: 2.5VA min/4VA max
9-32VDC: 1.5VA min/3VA max
Rated Circuit to Ground Voltage:
ACCURACY @ 25°C
±(0.5% of reading + 5 count) (50 Hz - 5Khz)
Decimal Point:
Unused
Display Hold:
Input Signal:
Input Power:
Using a screwdriver or thumbnail,
spread tab on each side of case to
unlock top half. Lift rear top half and
slide away from front of meter.
Wiring Display
Specifications
Display Scaling
OF METER
FRONT
0.5” (12.7mm)
3-position programmable
To select a decimal point, connect the appropriate DP pin (DP1, DP2, or DP3) to the DP COMMON (HOLD).
DP inputs may remain unconnected (open).
Connect HOLD to DP COMMON (HOLD). If this feature is not required, the DP COMMON (HOLD) pin may remain
unconnected (open).
Connect the IN HI and IN LO to the signal to be monitored.
Connect power to the L1 and L2 terminals. For AC powered units, L1 and L2 are not polarized.
For 9-32 DC powered units, L1 must be positive with respect to L2.
LOCKING
TOP HALF
OF CASE
TAB
These instruments are designed for maximum safety to the operator when mounted in a panel according to instruc-
(Input Signal) IN HI
(Input Signal) IN LO
tions. They are not to be used unmounted or for exploratory measurements in unknown circuits.
7
50VRMS
Mini-Max indicators have limited-range coarse
and fine adjustments for display scaling.
There are no optional connections required
for these to function. The “COARSE” calibra-
tion R12 will allow a limited range of scaling
values. The meter can be scaled down to 1/2
the value of the input or scaled up to 2 times
the value of the input or a maximum reading
of 1.999, which ever is lower. Example: a 2
Amp input has a maximum reading of 1.999
counts, so you can’t double the 2 amps, but
you can make 1 AMP to read 1.9999.
“FINE” calibration R9 allows for an approxi-
mate range of 1% of the “coarse” calibration.
Apply full scale input to the meter. Adjust R12
to be within 1% of the desired scaled value,
then use R9 to obtain the final desired result.
HOLD
ENVIRONMENTAL
Operating Temperature: 0 to 55°C
Storage Temperature: -10 to 60°C
Relative Humidity: 0 to 85% non condens-
ing @ 40°C
Temperature Coefficient:
(
Warmup time: Less than 20 minutes
NOISE REJECTION
NMRR: 60dB, 50/60Hz
CMRR: (w/1K unbalanced @ 60Hz) 90dB
min
ANALOG TO DIGITAL CONVERSION
Technique:
Rate: 3 samples/second-typical
DP3
DP2
DP1
0.02% of input
Integrating
0.2 digits)/ C
The
L1 (POS) (Power)
L2 (NEG) (Power)
EX (NEG)
EX (POS)
DP COMMON
(HOLD)
MECHANICAL
Bezel: 0.95” x 2.84” (24mm x 72mm)
Depth: 2.36” (60mm)
Panel cutout: 0.88” x 2.68”
Weight: 3.5oz (99g)
Case Material: 94-0,UL-rated, glass-filled
INPUTS: AC Current
Range
200µA
20mA
200mA
2mA
2A
5A
Note: Any physical damage to the meter
during calibration will void the warranty
Resolution
100nA
100µA
10mA
10µA
1mA
1µA
(22.2mm x 68mm)
thermoplastic
Voltage
200mV
200mV
200mV
200mV
200mV
50mV
Drop
Max Input
(unfused)
100mA
400mA
10mA
40mA
3A
6A