IDP-2 NEWPORT ELECTRONICS, IDP-2 Datasheet - Page 15

Digital Panel Meter Process

IDP-2

Manufacturer Part Number
IDP-2
Description
Digital Panel Meter Process
Manufacturer
NEWPORT ELECTRONICS
Datasheet

Specifications of IDP-2

No. Of Digits / Alpha
4
Meter Function
DC Process
Meter Range
0V To 5V / 1V To 5V / 0V To 10V / 4mA To 20mA
Digit Height
14.2mm
Power Consumption
3.5W
Operating Temperature Range
0°C To +50°C
Lead Free Status / RoHS Status
na
3.2 MOUNTING THE METER (Continued)
3.3 CONNECTING SENSOR INPUT
Figure 3-4. 3-Wire dc Voltage Input Connection
EXC
SIG
COM
with Internal Excitation
0
10Vdc
Figure 3-3. Panel Cut-Out
1
2
3
1
2
3
1
2
3
NOTE: Dimensions in Millimeters (Inches)
RTN
J2
HOLD
V
I
EXC
EXC
4 PLCS
R(.06)
(3.622 + .032/–.000)
1,5
92,00 + 0,81/–0,00
J3
J4
(1.772 + .024/–.000)
45,00 + 0,61/-0,00
PANEL THICKNESS
6,4 (.25) MAX
0,8 (.03) MIN

Related parts for IDP-2