Specifications of H3CR-F8 24AC/DC

Time Range
0.05 Sec To 30 Hr
Height
48mm
External Width
48mm
External Depth
78mm
H3CR-H
Accuracy of operating
time
Setting error
Operation start voltage
Influence of voltage
Influence of
temperature
Insulation resistance
Dielectric strength
Impulse withstand
voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient temperature
Ambient humidity
Life expectancy
EMC
Case color
Enclosure ratings
Weight
Characteristics
30 % max. of rated voltage
100 M min. (at 500 VDC)
2,000 VAC, 50/60 Hz for 1 min (between current-carrying metal parts and exposed non-current-carrying
metal parts)
2,000 VAC, 50/60 Hz for 1 min (between control output terminals and operating circuit)
2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
3 kV (between power terminals) for 100 to 120 VAC, 200 to 240 VAC, 100 to 125 VDC;
1 kV for 24 VAC/DC, 48 VDC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 120
VAC, 200 to 240 VAC, 100 to 125 VDC;
1.5 kV for 24 VAC/DC, 48 VDC
simulator (pulse width: 100 ns/1 ms, 1-ns rise);
Malfunction: 8 kV
Destruction: 15 kV
Destruction:10 to 55 Hz with 0.75-mm single amplitude for 2 hrs each in three directions
Malfunction:10 to 55 Hz with 0.5-mm single amplitude for 10 min each in three directions
Destruction: 980 m/s
Malfunction: 98 m/s
Operating:–10 C to 55 C (with no icing)
Storage: –25 C to 65 C (with no icing)
Operating: 35% to 85%
Mechanical:10 million operations min. (under no load at 1,200 operations/h)
Electrical:
(EMI)
Emission Enclosure:
Emission AC Mains:
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves:
Immunity RF-interference from Pulse-modulated Radio Waves:
Immunity Conducted Disturbance: ENV50141:
Immunity Burst:
Immunity Surge:
Light Gray (Munsell 5Y7/1)
IP40 (panel surface)
Approx. 120 g
0.2% FS max. ( 0.2% FS 10 ms max. in ranges of 0.6 and 1.2 s)
5% FS 50 ms max.
0.2% FS max. ( 0.2% FS 10 ms max. in ranges of 0.6 and 1.2 s)
1% FS max. ( 1% FS 10 ms max. in ranges of 0.6 and 1.2 s)
1.5 kV (between power terminals) and 600 V (between input terminals), square-wave noise by noise
1 kV (between power terminals) for 48 VDC
100,000 operations min. (5 A at 250 VAC, resistive load at 1,200 operations/h)
2
2
three times each in six directions
three times each in six directions
EN50081-2
EN55011 Group 1 class A
EN55011 Group 1 class A
EN50082-2
EN61000-4-2:
EN61000-4-4:
EN61000-4-5:
4 kV contact discharge (level 2)
8 kV air discharge (level 3)
ENV50140: 10 V/m (80 MHz to 1 GHz)
ENV50204: 10 V/m (900 5 MHz) (level 3)
10 V (0.15 to 80 MHz) (level 3)
2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
1 kV line to line (level 3)
2 kV line to ground (level 3)
(level 3)