G4ODC5R OPTO 22, G4ODC5R Datasheet - Page 2

I/O Module

G4ODC5R

Manufacturer Part Number
G4ODC5R
Description
I/O Module
Manufacturer
OPTO 22
Type
Outputr
Datasheets

Specifications of G4ODC5R

Accessory Type
Dry Contact Output Module
Leaded Process Compatible
No
Peak Reflow Compatible (260 C)
No
Supply Voltage Min
4.8VDC
No. Of Digital Outputs
1
Signal Input Type
Logic
Output Type
Relay
Brand/series
G4 Series
Connection To Host
Backplane
Contact Form
Reed
Current, Input
14 mA
Dimensions
48.8mmL×12.2mmW×41.1mmH
Number Of Channels
1
Output
100 VDC
Output, Range
100 VDC
Primary Type
Data Acquisition
Resistance, Input
200 Milliohms (Contact)
Standards
CE Approved
Temperature, Operating
-30 to +70 °C
Time, Turn-off
500 μS
Time, Turn-on
500 μS
Voltage, Isolation
1500 VDC
Voltage, Operating
0 to 100 VDC, 0 to 130 VAC (Line)
Voltage, Supply
5 VDC
Rohs Compliant
No
Contact Configuration
SPST-NO
No. Of Outputs
1
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
For Use With
SNAP PAC System

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
G4ODC5R
Manufacturer:
HIROSE ELECTRIC
Quantity:
17
PAGE
2
Specifications
Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com
SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com
© 2011 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations.
Contact form
Normal position
Contact rating
Maximum switching voltage
(see Note)
Maximum switching current
Contact resistance
Turn-on time
Turn-off time
Contact bounce
Mechanical life
Logic voltage range
Logic OFF voltage range
Logic ON voltage range
Indeterminate range
Logic input current at
nominal logic voltage
Isolation voltage (transient)
input-to-output
Ambient temperature:
Operating
Storage
*Part numbers ending in FM are Factory Mutual approved.
10 VA Rating for Reed Relay (Dry Contact) Modules
microseconds
microseconds
microseconds
Milliohms
milliamps
cycles
Units
VDC
VDC
VDC
VDC
VDC
VDC
VAC
VA
°C
°C
A
G4 Digital Dry Contact Output Modules
G4ODC5R
G4ODC5RFM*
mechanical relay
0.5 (see Note)
Form A SPST
-60 to +105
5 million
0.0–0.8
0.8–3.8
0 to 70
Open
4.8–6
3.8–6
1,500
100
130
200
500
500
250
10
14
G4ODC5R5
G4ODC5R5FM*
mechanical relay
0.5 (see Note)
Form B SPST
-60 to +105
5 million
0.8–3.8
0.0–0.8
Closed
0 to 70
4.8–6
3.8–6
1,500
100
130
200
500
500
250
10
14
NOTE: The application of
the dry contact module
must not exceed 10 VA
under steady-state or
momentary in-rush condi-
tions.
For voltages at or below 20
volts, the current limit is 0.5
amps. For voltages above
20 volts, the maximum
allowable current is deter-
mined by the following
equation:
Maximum Current =
10 VA / Voltage
Current Limit at Key Voltages:
1
is 100 VDC.
2
is 130 VAC.
Maximum DC voltage
Maximum AC voltage
100
130
120
12
24
V
5
1
2
500
500
416
100
mA
83
76

Related parts for G4ODC5R