SNAP-PAC-S1-W OPTO 22, SNAP-PAC-S1-W Datasheet
SNAP-PAC-S1-W
Specifications of SNAP-PAC-S1-W
Related parts for SNAP-PAC-S1-W
SNAP-PAC-S1-W Summary of contents
Page 1
... I/O system segment a control system’s network from the enterprise LAN. Wired+Wireless Communication SNAP-PAC-S1-W and SNAP-PAC-S2-W controllers add wireless capability to communications. In addition to the two wired network interfaces, these models have a wireless Part Numbers ...
Page 2
... PPP (Point-to-Point Protocol). These controllers also have one pluggable two-wire RS-485 port that can be used for SNAP PAC or mistic serial I/O units. For additional serial interfaces, you can add one or more SNAP serial communication modules on SNAP PAC racks connected to the controller ...
Page 3
... On a Wireless Controller LAN SNAP-PAC-S1 ---none--- SNAP-PAC-S1-FM SNAP-PAC-S2 SNAP-PAC-S1-W SNAP-PAC-R1-W SNAP-PAC-S2-W SNAP-PAC-R2-W SNAP-PAC-EB1-W SNAP-PAC-EB2-W * Legacy I/O processors; not recommended for new development SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com © ...
Page 4
... RTS, CTS RS-485 (2-wire, 4-wire, optional termination, optional biasing); optional mistic signal interrupts. Buffer size: 512 bytes each for RX and TX. Opto 22 SNAP PAC R-series, SNAP PAC EB-series, SNAP SIO, SNAP EIO, and SNAP UIO brains SNAP PAC SB-series, Serial B3000, SNAP-BRS, B100/B200, mistic remote bricks (G4D16R, G4D32RS, G4A8R) 8– ...
Page 5
... Warranty 30 months from date of manufacture * Requires a Wired+Wireless model (SNAP-PAC-S1-W or SNAP-PAC-S2-W) SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com © 2006–2011 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. ...
Page 6
... SNAP PAC S-series controller controls all I/O units. I/O units are connected via a 2-wire RS-485 serial network and are controlled by the SNAP PAC S-series controller. Each I/O unit is connected to its own group of sensors and actuators. Sensors and actuators, location #2 The diagram also shows a PC running PAC Control Professional ...
Page 7
... Modem Sensors and actuators, location #1 I/O units are connected via a 2-wire RS-485 serial network and are controlled by the SNAP PAC S-series controller. Each I/O unit is connected to its own group of sensors and actuators. Sensors and actuators, location #3 SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com © ...
Page 8
... Wired+Wireless SNAP PAC S-series Controller The Wired+Wireless PAC can communicate with devices on wired networks wireless LAN both at once. It can also simultaneously communicate serially. PC running PAC Display SNAP-PAC-S1-W controller controls all I/O units. Serial I/O units The Wired+Wireless SNAP PAC S-series controller is ...
Page 9
... Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. This diagram shows multiple Opto 22 Enterprise Network SNAP I/O units connected together over an Ethernet network and controlled by a SNAP PAC S-series controller running a control strategy. The controller is also connected to a larger, separate enterprise Ethernet network to provide data to two PCs running Opto 22’ ...
Page 10
... In this configuration, if one network goes down, devices can still communicate on the other. Each PC has two network interface cards (NICs), and the SNAP PAC S-series controller and the I/O units (SNAP PAC R-series) have two network interfaces as well. If you are using Wired+Wireless PACs, one of these networks can be a wireless LAN ...
Page 11
... SNAP PAC controller The two controllers you use must be exactly the same part number (for example, two SNAP-PAC-S2 controllers or two SNAP-PAC-S1-W controllers). One advantage of an Opto 22 redundant system is that it uses standard PACs, standard cabling, and standard I/O. Another advantage is that either controller can act as the active or backup controller ...
Page 12
... SNAP-PAC-S1 Connectors and Indicators This diagram applies to both the SNAP-PAC-S1 and the SNAP- PAC-S1-FM. Controller reset button DIP switches for RS-485 serial link Bias Termination Port 2 for RS-485 serial communications (pins 1–5 of pluggable 10-pin connector) Port 1 for RS-232 serial communications (pins 6–10 of ...
Page 13
... SNAP PAC S-Series Controllers SNAP-PAC-S1-W Connectors and Indicators (Wired+Wireless) Controller reset button DIP switches for RS-485 serial link Bias Termination Port 2 for RS-485 serial communications (pins 1–5 of pluggable 10-pin connector) Port 1 for RS-232 serial communications (pins 6–10 of pluggable 10-pin connector) Port 0 for RS-232 serial communications (DB-9 connector) with handshaking ...
Page 14
... DCD 1 CAUTION: Do not use communication port connectors from a legacy OptoControl controller*. Legacy connectors will fit in a SNAP-PAC-S2, but the pin orientation is different. Instead, use the connectors supplied with the SNAP-PAC-S2 controller. 2 Isolated ground. (Each channel is isolated from the others.) *Legacy OptoControl Controllers: ...
Page 15
... In 1 CAUTION: Do not use communication port connectors from a legacy OptoControl controller*. Legacy connectors will fit in a SNAP-PAC-S2, but the pin orientation is different. Instead, use the connectors supplied with the SNAP-PAC-S2 controller. 2 Isolated ground. (Each channel is isolated from the others.) *Legacy OptoControl Controllers: ...
Page 16
... Dimensional Drawings SNAP-PAC-S1 and SNAP-PAC-S1-FM Panel Mounting and Dimensions For SNAP-PAC-S1-W dimensions, see Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com PAGE SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com 16 © ...
Page 17
... SNAP-PAC-S1 and SNAP-PAC-S1-FM DIN-Rail Mounting and Dimensions Requires a SNAP-PSDIN adapter (purchased separately). SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com © 2006–2011 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. ...
Page 18
... Dimensional Drawings (continued) SNAP-PAC-S2 Panel Mounting and Dimensions For SNAP-PAC-S2-W dimensions, see Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com PAGE SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com 18 © ...
Page 19
... Dimensional Drawings (continued) SNAP-PAC-S2 DIN-Rail Mounting and Dimensions Requires a SNAP-S2DIN adapter (purchased separately). SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com © 2006–2011 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. ...
Page 20
... Dimensional Drawings (continued) SNAP-PAC-S1-W Dimensions Opto 22 • 43044 Business Park Drive • Temecula, CA 92590-3614 • www.opto22.com PAGE SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com 20 © 2006–2011 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. ...
Page 21
... SNAP PAC S-Series Controllers Dimensional Drawings (continued) SNAP-PAC-S2-W Dimensions SALES 800-321-6786 • 951-695-3000 • FAX 951-695-3095 • sales@opto22.com • SUPPORT 800-835-6786 • 951-695-3080 • FAX 951-695-3017 • support@opto22.com © 2006–2011 Opto 22. All rights reserved. Dimensions and specifications are subject to change. Brand or product names used herein are trademarks or registered trademarks of their respective companies or organizations. ...
Page 22
... SNAP I/O I/O provides the local connection to sensors and equipment. Opto 22 SNAP I/O offers points of reliable I/O per module, depending on the type of module and your needs. Analog, digital, serial, and special-purpose modules are all mixed on the same mounting rack and controlled by the same processor (SNAP PAC brain or rack-mounted controller) ...