6SL3255-0AA00-4BA1 SIEMENS, 6SL3255-0AA00-4BA1 Datasheet - Page 15
6SL3255-0AA00-4BA1
Manufacturer Part Number
6SL3255-0AA00-4BA1
Description
TOUCHPANEL, BOP SINAMICS G110
Manufacturer
SIEMENS
Datasheet
1.6SL3255-0AA00-4BA1.pdf
(20 pages)
Specifications of 6SL3255-0AA00-4BA1
Ip/nema Rating
IP20
For Use With
SINAMICS G110 Frequency Inverter
■
■
Variant independent options
Overview
Basic Operator Panel (BOP)
The BOP can be used to make individual parameter settings.
Values and units are shown on a 5-digit display.
One BOP can be used for several inverters. It is directly plugged
into the inverter.
The BOP offers a parameter cloning function, which enables a
parameter set from one inverter to be saved and then down-
loaded to another inverter.
PC to inverter connection kit
For controlling and commissioning an inverter directly from a PC
if the appropriate software (STARTER) has been installed.
Isolated RS232 adapter board for reliable point to point connec-
tion to a PC.
It offers a 9-pin Sub-D connector and an RS232 standard cable
(3 m).
Commissioning tool
STARTER is a graphic start-up tool for commissioning
SINAMICS G110 frequency inverters under Windows
NT/2000/XP Professional. Parameter lists can be read out,
altered, stored, read in and printed.
Selection and Ordering Data
The options listed here are suitable for all SINAMICS G110 in-
verters.
Options
Basic Operator Panel (BOP)
PC to inverter connection kit
Adapter for mounting on
DIN rail, Size 1 (FS A)
Adapter for mounting on
DIN rail, Size 2 (FS B)
STARTER commissioning tool on
CD-ROM,
including: operating instruc-
tions, parameter list, Getting
Started Guide
1
)
Order no.
6SL3255-0AA00-4BA0
6SL3255-0AA00-2AA0
6SL3261-1BA00-0AA0
6SL3261-1BB00-0AA0
6SL3271-0CA00-0AG0
■
Selection and Ordering Data
1) Documentation is also available on the Internet at
Type of documentation
Operating instructions
(paper version)
Parameter list
(paper version)
Getting Started Guide
http://www.siemens.com/sinamics-g110
1
)
1
Siemens D 11.1 · December 2003
1
) Multilanguage
)
Language
German
English
French
Italian
Spanish
German
English
French
Italian
Spanish
Order no.
6SL3298-0AA11-0AP0
6SL3298-0AA11-0BP0
6SL3298-0AA11-0DP0
6SL3298-0AA11-0CP0
6SL3298-0AA11-0EP0
6SL3298-0BA11-0AP0
6SL3298-0BA11-0BP0
6SL3298-0BA11-0DP0
6SL3298-0BA11-0CP0
6SL3298-0BA11-0EP0
A paper version is sup-
plied with each inverter.
Chassis units
Documentation
13