72.01.9.024.0000 FINDER, 72.01.9.024.0000 Datasheet

RELAY, LEVEL CONTROL, 24V

72.01.9.024.0000

Manufacturer Part Number
72.01.9.024.0000
Description
RELAY, LEVEL CONTROL, 24V
Manufacturer
FINDER
Datasheet

Specifications of 72.01.9.024.0000

Accessory Type
Level Monitoring Relay
Voltage Rating
24VDC
Current Rating
16A
Length
84mm
External Width
35mm
External Depth
58mm
Svhc
No SVHC (15-Dec-2010)
For Use With
Level Monitoring And Control
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Features
Level control relays for conductive liquids
72.01 - Adjustable sensitivity
72.11 - Fixed sensitivity
F
S
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated voltage/Maximum switching voltage V AC
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Supply specification
Nominal voltage (U
Rated power AC/DC
Operating range
Technical data
Electrical life at rated load AC1
Electrode voltage
Electrode current
Run-on time
Max sensitivity range
Insulation between supply/contacts/electrode (1.2/50 µs) kV
Ambient temperature
Protection category
Approvals (according to type)
Emptying or filling functions
LED indicator
Reinforced insulation (6 kV - 1.2/50 µs) between:
- supply and contacts
- electrodes and supply
- contacts and electrodes
35 mm rail (EN 50022) mount
Control about a single level or between
Min./Max. limits
72.01 available also for supply 400 V
OR
EE
“General technical information” page V
UL H
ORSEPOWER AND
35
N
)
P
ILOT
42.3
D
54.6
58
UTY RATINGS
VA (50 Hz)/W
mW (V/mA)
cycles
V AC
V DC
V AC
kW
mA
AC
DC
VA
VA
kΩ
°C
A
A
s
24 - 110...125 – 230...240
Sensitivity range (5...150) kΩ adjustable
Delay time (0.5s or 7s) switch selectable
Emptying or filling functions switch selectable
L/+
N/-
B1 B2
A1 A2
(0.8...1.1)U
(0.8...1.1)U
LEVEL
2.5/1.5
5…150 (adjustable)
24
0.5 - 7 (selectable)
12
B3
FL = Filing – 7s delay
FS = Filling – 0.5s delay
ES = Emptying – 0.5s delay
EL = Emptying – 7s delay
16/0.3/0.12
U = 24 V DC
1 CO (SPDT)
500 (10/5)
–20…+60
250/400
100 · 10
11 14
AgCdO
72.01
24 V AC 50/60 Hz
(110...125)V AC 50/60 Hz
(230...240)V AC 50/60 Hz
16/30
4,000
N
N
0.55
IP20
750
0.2
4
6
R = (5…150)kΩ
3
FS
72 Series - Monitoring relays 16 A
(0.9...1.15)U
FL
FS
ES
EL
2.5/1.5
400
N
Sensitivity fixed 150 kΩ
Delay time fixed: 1s
Emptying or filling functions link selectable
L/+
N/-
A1 A2
B1 B2 B3
24 - 110...125 – 230...240
LEVEL
12
16/0.3/0.12
U = 24 V DC
(0.8...1.1)U
(0.8...1.1)U
1 CO (SPDT)
500 (10/5)
Z1 Z2
150 (fixed)
–20…+60
250/400
100 · 10
11 14
2.5/1.5
AgCdO
24 V AC 50/60 Hz
(110...125)V AC 50/60 Hz
(230...240)V AC 50/60 Hz
72.11
16/30
4,000
0.55
IP20
750
0.2
24
4
1
6
T = 1 s
R = 150 kΩ
3
Z1 Z2
Z1 Z2
N
N
E = Emptying
F = Filling
1

Related parts for 72.01.9.024.0000

72.01.9.024.0000 Summary of contents

Page 1

Features Level control relays for conductive liquids 72.01 - Adjustable sensitivity 72.11 - Fixed sensitivity Emptying or filling functions • LED indicator • Reinforced insulation ( 1.2/50 µs) between: • - supply and contacts - electrodes and supply ...

Page 2

Features 3 Phase - Rotation and phase loss monitoring relay Universal voltage monitoring • (U from 208 V to 480 V, 50/60 Hz) N Phase loss monitoring, under phase regeneration • Positive safety logic - make contact opens • if ...

Page 3

Ordering information Level control relays Example: 72 series level control relay, adjustable sensitivity range, (230…240)V AC supply voltage Series Type 0 = Sensitivity range adjustable (5...150)kΩ rail (EN 50022) mount 1 = Sensitivity fixed ...

Page 4

Technical data for 72.01 and 72.11 Insulation Insulation between supply and contacts between electrodes, Z1-Z2 and supply* between contacts and electrodes between open contacts EMC specifications Type of test Electrostatic discharge contact discharge air discharge Radio-frequency electromagnetic field (80 ÷ ...

Page 5

Functions for 72.01 and 72. Supply voltage B1 = Max level electrode B2 = Min level electrode B3 = Common = Contact 11-14 Z1-Z2 = Link to select emptying (Type 72.11) Function and Run-on time Type 72.01 FL ...

Page 6

Emptying functions Wiring diagram Examples with 3 electrodes Type 72. L/+ N 50/60 Hz (110...125)V AC 50/ (230...240)V AC 50/ Level ...

Page 7

Functions for 72.31 L1, L2 Supply voltage = Contact 11 (208...480 (50/ Series - Monitoring relays ...

Page 8

Accessories for 72.01 and 72.11 Suspended electrode for conductive liquids, complete with cable. Suitable for level monitoring in wells and reservoirs not under pressure. All materials used are compatible with food processing applications (according to European Directive 2002/72 and cod. ...

Page 9

Accessories for 72.01 and 72.11 Electrode and electrode connector, multiple electrodes may be interconneced to provide required length Technical data Electrode - 500 mm long, M4 thread, stainless steel Inter-electrode connector - M4 thread, stainless steel 072.500 Illustration of interconnection ...

Page 10

Application notes for 72.01 and 72.11 Applications The main application for these relays is for the sensing and control of the level of conductive liquids. Selectable options allow for this control to be achieved either through a filling operation or ...

Related keywords